284 related articles for article (PubMed ID: 18544811)
1. On-electrode autonomous current generator for multi-frequency EIT.
Jivet I; Dragoi B
Physiol Meas; 2008 Jun; 29(6):S193-201. PubMed ID: 18544811
[TBL] [Abstract][Full Text] [Related]
2. Multi-frequency EIT system with radially symmetric architecture: KHU Mark1.
Oh TI; Woo EJ; Holder D
Physiol Meas; 2007 Jul; 28(7):S183-96. PubMed ID: 17664635
[TBL] [Abstract][Full Text] [Related]
3. Comparison of a new integrated current source with the modified Howland circuit for EIT applications.
Hong H; Rahal M; Demosthenous A; Bayford RH
Physiol Meas; 2009 Oct; 30(10):999-1007. PubMed ID: 19706961
[TBL] [Abstract][Full Text] [Related]
4. [An experimental system of induced-current EIT].
Dong X; You F; Qin M; Shi X; Liu R; Xiang H; Fu F; Cui W
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Jun; 21(3):416-9. PubMed ID: 15250146
[TBL] [Abstract][Full Text] [Related]
5. Low-noise current excitation sub-system for medical EIT.
Rafiei-Naeini M; McCann H
Physiol Meas; 2008 Jun; 29(6):S173-84. PubMed ID: 18544814
[TBL] [Abstract][Full Text] [Related]
6. A multi-frequency EIT system design based on telecommunication signal processors.
Robitaille N; Guardo R; Maurice I; Hartinger AE; Gagnon H
Physiol Meas; 2009 Jun; 30(6):S57-71. PubMed ID: 19491440
[TBL] [Abstract][Full Text] [Related]
7. The simulation of current generator design for multi-frequency electrical impedance tomograph.
Chen CY; Lu YY; Huang WL; Cheng KS
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():6072-5. PubMed ID: 17945933
[TBL] [Abstract][Full Text] [Related]
8. A 32-electrode data collection system for electrical impedance tomography.
Koukourlis CS; Kyriacou GA; Sahalos JN
IEEE Trans Biomed Eng; 1995 Jun; 42(6):632-6. PubMed ID: 7790020
[TBL] [Abstract][Full Text] [Related]
9. Electrical impedance tomography system based on active electrodes.
Gaggero PO; Adler A; Brunner J; Seitz P
Physiol Meas; 2012 May; 33(5):831-47. PubMed ID: 22531225
[TBL] [Abstract][Full Text] [Related]
10. Calibration methods for a multi-channel multi-frequency EIT system.
Oh TI; Lee KH; Kim SM; Koo H; Woo EJ; Holder D
Physiol Meas; 2007 Oct; 28(10):1175-88. PubMed ID: 17906386
[TBL] [Abstract][Full Text] [Related]
11. A review of errors in multi-frequency EIT instrumentation.
McEwan A; Cusick G; Holder DS
Physiol Meas; 2007 Jul; 28(7):S197-215. PubMed ID: 17664636
[TBL] [Abstract][Full Text] [Related]
12. Systematic errors of EIT systems determined by easily-scalable resistive phantoms.
Hahn G; Just A; Dittmar J; Hellige G
Physiol Meas; 2008 Jun; 29(6):S163-72. PubMed ID: 18544805
[TBL] [Abstract][Full Text] [Related]
13. A comparison study of electrodes for neonate electrical impedance tomography.
Rahal M; Khor JM; Demosthenous A; Tizzard A; Bayford R
Physiol Meas; 2009 Jun; 30(6):S73-84. PubMed ID: 19491443
[TBL] [Abstract][Full Text] [Related]
14. Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging.
Woo EJ; Seo JK
Physiol Meas; 2008 Oct; 29(10):R1-26. PubMed ID: 18799834
[TBL] [Abstract][Full Text] [Related]
15. Real-time management of faulty electrodes in electrical impedance tomography.
Hartinger AE; Guardo R; Adler A; Gagnon H
IEEE Trans Biomed Eng; 2009 Feb; 56(2):369-77. PubMed ID: 19272943
[TBL] [Abstract][Full Text] [Related]
16. A comparison of modified Howland circuits as current generators with current mirror type circuits.
Bertemes-Filho P; Brown BH; Wilson AJ
Physiol Meas; 2000 Feb; 21(1):1-6. PubMed ID: 10719993
[TBL] [Abstract][Full Text] [Related]
17. Waveform generator for electrical impedance tomography (EIT) using linear interpolation with multiplying D/A converters.
Blad B; Johannesson J; Johnsson G; Bachman B; Lindström K
J Med Eng Technol; 1994; 18(5):173-8. PubMed ID: 7776358
[TBL] [Abstract][Full Text] [Related]
18. Stable, inexpensive, low-frequency sine wave generator using digital techniques.
Podolske J
Rev Sci Instrum; 1979 Aug; 50(8):1010-2. PubMed ID: 18699654
[TBL] [Abstract][Full Text] [Related]
19. A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2.
Oh TI; Wi H; Kim DY; Yoo PJ; Woo EJ
Physiol Meas; 2011 Jul; 32(7):835-49. PubMed ID: 21646706
[TBL] [Abstract][Full Text] [Related]
20. Electrical nerve and muscle stimulation by radio frequency surgery: role of direct current loops around the active electrode.
Slager CJ; Schuurbiers JC; Oomen JA; Bom N
IEEE Trans Biomed Eng; 1993 Feb; 40(2):182-7. PubMed ID: 8319969
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]