These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 1855236)

  • 1. A new catheter configuration for selective antegrade catheterization of the superficial femoral artery: technical note.
    Bohndorf K; Günther RW
    Cardiovasc Intervent Radiol; 1991; 14(2):129-31. PubMed ID: 1855236
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On-Site-Modified Sheath to Overcome the Undesirable Catheterization of the Profunda Femoris Artery During Antegrade Femoral Access.
    Ysa A; Lobato M; Arruabarrena A; Quintana AM; Gómez R; Ortiz de Salazar L; Metcalfe M; Fonseca JL
    J Endovasc Ther; 2020 Jun; 27(3):505-508. PubMed ID: 32193967
    [No Abstract]   [Full Text] [Related]  

  • 3. "Retroantegrade" catheterization of the branches of the femoral artery: technical note.
    Giavroglou CE
    Cardiovasc Intervent Radiol; 1989 Nov-1990 Dec; 12(6):337-9. PubMed ID: 2516776
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Antegrade puncture of the superficial femoral artery: a pilot project].
    Blais C
    Can Assoc Radiol J; 1993 Aug; 44(4):253-6. PubMed ID: 8348351
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Directional needle for antegrade guide wire placement with vertical arterial puncture.
    Hawkins JS; Coryell LW; Miles SG; Giovannetti MJ; Siragusa RJ; Hawkins IF
    Radiology; 1988 Jul; 168(1):271-2. PubMed ID: 3380973
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Easy technique to overcome the undesirable catheterization of the profunda femoral artery during antegrade femoral access.
    Ysa A; Bustabad MR; Arruabarrena A; Peña M; Fonseca JL
    Ann Vasc Surg; 2010 Aug; 24(6):841-3. PubMed ID: 20413262
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Antegrade superficial femoral artery versus common femoral artery punctures for infrainguinal occlusive disease.
    Kweon M; Bhamidipaty V; Holden A; Hill AA
    J Vasc Interv Radiol; 2012 Sep; 23(9):1160-4. PubMed ID: 22832141
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An improved reversal technique from retrograde to antegrade femoral artery cannulation.
    Hartnell G
    Cardiovasc Intervent Radiol; 1998; 21(6):512-3. PubMed ID: 9853173
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simplified technique for converting antegrade femoral access to retrograde access for catheterization.
    Nazir S; Elzanaty AM; Moukarbel GV
    Vascular; 2021 Feb; 29(1):143-145. PubMed ID: 32631133
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new simple method of converting a retrograde femoral access to an antegrade catheterization.
    Ysa A; Lobato M; Gómez R; Arruabarrena A; Metcalfe M; Fonseca JL
    J Vasc Surg; 2014 Sep; 60(3):792-5. PubMed ID: 24797552
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sonographically guided antegrade common femoral artery access.
    Yeow KM; Toh CH; Wu CH; Lee RY; Hsieh HC; Liau CT; Li HJ
    J Ultrasound Med; 2002 Dec; 21(12):1413-6. PubMed ID: 12494984
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of skin entry site, needle angulation and soft tissue compression on simulated antegrade and retrograde femoral arterial punctures: an anatomical study using Cartesian co-ordinates derived from CT angiography.
    Tam MD; Lewis M
    Surg Radiol Anat; 2012 Oct; 34(8):751-5. PubMed ID: 21971644
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Retrograde recanalization technique for use after failed antegrade angioplasty in chronic femoral artery occlusions.
    Schmidt A; Bausback Y; Piorkowski M; Werner M; Bräunlich S; Ulrich M; Varcoe R; Friedenberger J; Schuster J; Botsios S; Scheinert D
    J Endovasc Ther; 2012 Feb; 19(1):23-9. PubMed ID: 22313197
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new puncture needle (Seldinger technique) for easy antegrade catheterization of the superficial femoral artery.
    Saltzman J; Probst P
    Eur J Radiol; 1987 Feb; 7(1):54-5. PubMed ID: 3830192
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Retrograde vs. antegrade puncture for infra-inguinal angioplasty.
    Nice C; Timmons G; Bartholemew P; Uberoi R
    Cardiovasc Intervent Radiol; 2003; 26(4):370-4. PubMed ID: 14667119
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy and safety of antegrade common femoral artery access closure using the Angio-Seal device: experience with 1889 interventions for critical limb ischemia in diabetic patients.
    Lupattelli T; Tannouri F; Garaci FG; Papa G; Pangos M; Somalvico F; Caravaggi C; Faglia E
    J Endovasc Ther; 2010 Jun; 17(3):366-75. PubMed ID: 20557177
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tunneled Ipsilateral Sheath: A Novel Technique in Endovascular Management of Superficial Femoral Artery Ostial Lesions.
    El-Maadawy MI; Balboula AM; Zaghloul H
    Vasc Endovascular Surg; 2019 May; 53(4):337-340. PubMed ID: 30606079
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Angioplasty from the contralateral approach: use of a guiding catheter and coaxial angioplasty balloons.
    Kaufman SL
    Radiology; 1990 Nov; 177(2):577-8. PubMed ID: 2145610
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility and Safety of Reverse Catheterization Technique of the Superficial Femoral Artery in Single-Stage Endovascular Treatment of Bilateral Infrainguinal Diseases.
    Kadoya Y; Zen K; Kato T; Wada N; Wakana N; Yanishi K; Nakanishi N; Nakamura T; Matoba S
    Vasc Endovascular Surg; 2019 Apr; 53(3):206-211. PubMed ID: 30563435
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Suitability of a 7-F ExoSeal Vascular Closure Device for Femoral Artery Punctures Made by 8-F or 9-F Introducer Sheaths.
    Goto S; Ohshima T; Ishikawa K; Yamamoto T; Nishizawa T; Shimato S; Kato K
    J Endovasc Ther; 2017 Aug; 24(4):516-520. PubMed ID: 28743227
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.