These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 18556124)

  • 1. Atomic-scale electron microscopy at ambient pressure.
    Creemer JF; Helveg S; Hoveling GH; Ullmann S; Molenbroek AM; Sarro PM; Zandbergen HW
    Ultramicroscopy; 2008 Aug; 108(9):993-8. PubMed ID: 18556124
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of total beam current on HRTEM image resolution in differentially pumped ETEM with nitrogen gas.
    Bright AN; Yoshida K; Tanaka N
    Ultramicroscopy; 2013 Jan; 124():46-51. PubMed ID: 23142744
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-situ TEM on (de)hydrogenation of Pd at 0.5-4.5 bar hydrogen pressure and 20-400°C.
    Yokosawa T; Alan T; Pandraud G; Dam B; Zandbergen H
    Ultramicroscopy; 2012 Jan; 112(1):47-52. PubMed ID: 22088507
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Environmental electron microscopy (ETEM) for catalysts with a closed E-cell with carbon windows.
    Giorgio S; Sao Joao S; Nitsche S; Chaudanson D; Sitja G; Henry CR
    Ultramicroscopy; 2006 Apr; 106(6):503-7. PubMed ID: 16515837
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Controlled environment specimen transfer.
    Damsgaard CD; Zandbergen H; W Hansen T; Chorkendorff I; B Wagner J
    Microsc Microanal; 2014 Aug; 20(4):1038-45. PubMed ID: 24824787
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Method for local temperature measurement in a nanoreactor for in situ high-resolution electron microscopy.
    Vendelbo SB; Kooyman PJ; Creemer JF; Morana B; Mele L; Dona P; Nelissen BJ; Helveg S
    Ultramicroscopy; 2013 Oct; 133():72-9. PubMed ID: 23831940
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In situ TEM study of catalytic nanoparticle reactions in atmospheric pressure gas environment.
    Xin HL; Niu K; Alsem DH; Zheng H
    Microsc Microanal; 2013 Dec; 19(6):1558-68. PubMed ID: 24011167
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A (S)TEM gas cell holder with localized laser heating for in situ experiments.
    Mehraeen S; McKeown JT; Deshmukh PV; Evans JE; Abellan P; Xu P; Reed BW; Taheri ML; Fischione PE; Browning ND
    Microsc Microanal; 2013 Apr; 19(2):470-8. PubMed ID: 23452391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Environmental transmission electron microscopy for catalyst materials using a spherical aberration corrector.
    Takeda S; Kuwauchi Y; Yoshida H
    Ultramicroscopy; 2015 Apr; 151():178-190. PubMed ID: 25498142
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope.
    Unocic KA; Hensley DK; Walden FS; Bigelow WC; Griffin MB; Habas SE; Unocic RR; Allard LF
    J Vis Exp; 2021 Jul; (173):. PubMed ID: 34369934
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a 300-kV gas environmental transmission electron microscope equipped with a cold field emission gun.
    Isakozawa S; Nagaoki I; Watabe A; Nagakubo Y; Saito N; Matsumoto H; Zhang XF; Taniguchi Y; Baba N
    Microscopy (Oxf); 2016 Aug; 65(4):353-62. PubMed ID: 27142511
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A method for measuring the local gas pressure within a gas-flow stage in situ in the transmission electron microscope.
    Colby R; Alsem DH; Liyu A; Kabius B
    Ultramicroscopy; 2015 Jun; 153():55-60. PubMed ID: 25765435
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atomic-resolution environmental TEM for quantitative in-situ microscopy in materials science.
    Takeda S; Yoshida H
    Microscopy (Oxf); 2013 Feb; 62(1):193-203. PubMed ID: 23325929
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Novel MEMS-based gas-cell/heating specimen holder provides advanced imaging capabilities for in situ reaction studies.
    Allard LF; Overbury SH; Bigelow WC; Katz MB; Nackashi DP; Damiano J
    Microsc Microanal; 2012 Aug; 18(4):656-66. PubMed ID: 22835379
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Temperature Calibration for In Situ Environmental Transmission Electron Microscopy Experiments.
    Winterstein JP; Lin PA; Sharma R
    Microsc Microanal; 2015 Dec; 21(6):1622-1628. PubMed ID: 26441334
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In Situ Ptychography of Heterogeneous Catalysts using Hard X-Rays: High Resolution Imaging at Ambient Pressure and Elevated Temperature.
    Baier S; Damsgaard CD; Scholz M; Benzi F; Rochet A; Hoppe R; Scherer T; Shi J; Wittstock A; Weinhausen B; Wagner JB; Schroer CG; Grunwaldt JD
    Microsc Microanal; 2016 Feb; 22(1):178-88. PubMed ID: 26914998
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Single Atom Dynamics in Chemical Reactions.
    Boyes ED; LaGrow AP; Ward MR; Mitchell RW; Gai PL
    Acc Chem Res; 2020 Feb; 53(2):390-399. PubMed ID: 32022555
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On-chip gas reaction nanolab for
    Zhao T; Jiang Y; Luo S; Ying Y; Zhang Q; Tang S; Chen L; Xia J; Xue P; Zhang JJ; Sun SG; Liao HG
    Lab Chip; 2023 Aug; 23(17):3768-3777. PubMed ID: 37489871
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Environmental Transmission Electron Microscopy Study of Diesel Carbon Soot Combustion under Simulated Catalytic-Reaction Conditions.
    Mori K; Watanabe K; Sato T; Yamashita H
    Chemphyschem; 2015 May; 16(7):1347-51. PubMed ID: 25603930
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In Situ Observation of Hydrogen-Induced Surface Faceting for Palladium-Copper Nanocrystals at Atmospheric Pressure.
    Jiang Y; Li H; Wu Z; Ye W; Zhang H; Wang Y; Sun C; Zhang Z
    Angew Chem Int Ed Engl; 2016 Sep; 55(40):12427-30. PubMed ID: 27593991
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.