423 related articles for article (PubMed ID: 18559350)
1. Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study.
Steinmann D; Stahl CA; Minner J; Schumann S; Loop T; Kirschbaum A; Priebe HJ; Guttmann J
Br J Anaesth; 2008 Sep; 101(3):411-8. PubMed ID: 18559350
[TBL] [Abstract][Full Text] [Related]
2. Electrical impedance tomography for verification of correct endotracheal tube placement in paediatric patients: a feasibility study.
Steinmann D; Engehausen M; Stiller B; Guttmann J
Acta Anaesthesiol Scand; 2013 Aug; 57(7):881-7. PubMed ID: 23750708
[TBL] [Abstract][Full Text] [Related]
3. The incidence of right upper-lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery.
Campos JH; Massa FC; Kernstine KH
Anesth Analg; 2000 Mar; 90(3):535-40. PubMed ID: 10702432
[TBL] [Abstract][Full Text] [Related]
4. A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic Surgery.
Heir JS; Guo SL; Purugganan R; Jackson TA; Sekhon AK; Mirza K; Lasala J; Feng L; Cata JP
J Cardiothorac Vasc Anesth; 2018 Feb; 32(1):267-274. PubMed ID: 29074128
[TBL] [Abstract][Full Text] [Related]
5. Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation.
Inoue S; Nishimine N; Kitaguchi K; Furuya H; Taniguchi S
Br J Anaesth; 2004 Feb; 92(2):195-201. PubMed ID: 14722168
[TBL] [Abstract][Full Text] [Related]
6. Positioning of double-lumen tubes based on the minimum peak inspiratory pressure difference between the right and left lungs in short patients: a prospective observational study.
Kim SH; Choi YS; Shin S; Cho JS; Nam DJ; Oh YJ
Eur J Anaesthesiol; 2014 Mar; 31(3):137-42. PubMed ID: 24047768
[TBL] [Abstract][Full Text] [Related]
7. Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker.
Campos JH; Massa FC
Anesth Analg; 1998 Apr; 86(4):696-700. PubMed ID: 9539585
[TBL] [Abstract][Full Text] [Related]
8. Comparing the placement of a left-sided double-lumen tube via fiberoptic bronchoscopy guidance versus conventional intubation using a Macintosh laryngoscope, to reduce the incidence of malpositioning: study protocol for a randomized controlled pilot trial.
Ryu T; Kim E; Kim JH; Woo SJ; Roh WS; Byun SH
Trials; 2019 Jan; 20(1):51. PubMed ID: 30646931
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of blind thoracoscopic-assisted placement of three double-lumen endobronchial tube designs for one-lung ventilation in dogs.
Mayhew PD; Culp WT; Pascoe PJ; Kass PH; Johnson LR
Vet Surg; 2012 Aug; 41(6):664-70. PubMed ID: 22822939
[TBL] [Abstract][Full Text] [Related]
10. A new and simple maneuver to position the left-sided double-lumen tube without the aid of fiberoptic bronchoscopy.
Bahk JH; Oh YS
Anesth Analg; 1998 Jun; 86(6):1271-5. PubMed ID: 9620518
[TBL] [Abstract][Full Text] [Related]
11. Modified right-sided Broncho-Cath double lumen tube improves endobronchial positioning: a randomized study.
Bussières JS; Lacasse Y; Côté D; Beauvais M; St-Onge S; Lemieux J; Soucy J
Can J Anaesth; 2007 Apr; 54(4):276-82. PubMed ID: 17400979
[TBL] [Abstract][Full Text] [Related]
12. Reliability of auscultation in positioning of double-lumen endobronchial tubes.
Alliaume B; Coddens J; Deloof T
Can J Anaesth; 1992 Sep; 39(7):687-90. PubMed ID: 1394757
[TBL] [Abstract][Full Text] [Related]
13. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery?
de Bellis M; Accardo R; Di Maio M; La Manna C; Rossi GB; Pace MC; Romano V; Rocco G
Eur J Cardiothorac Surg; 2011 Oct; 40(4):912-6. PubMed ID: 21802958
[TBL] [Abstract][Full Text] [Related]
14. [Estimation of the position of right-sided double-lumen endobronchial tubes with spirometry in elderly patients].
Ye J; Ouyang BY; Dong QL
Nan Fang Yi Ke Da Xue Xue Bao; 2009 Mar; 29(3):469-71. PubMed ID: 19304527
[TBL] [Abstract][Full Text] [Related]
15. [Influence of the position of double-lumen endobronchial tube on the efficacy of lung separation and ventilation].
Hou HW; Ouyang BY
Nan Fang Yi Ke Da Xue Xue Bao; 2006 May; 26(5):576-8. PubMed ID: 16762853
[TBL] [Abstract][Full Text] [Related]
16. Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy.
Bauer C; Winter C; Hentz JG; Ducrocq X; Steib A; Dupeyron JP
Acta Anaesthesiol Scand; 2001 Feb; 45(2):250-4. PubMed ID: 11167173
[TBL] [Abstract][Full Text] [Related]
17. The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures.
Lewis JW; Serwin JP; Gabriel FS; Bastanfar M; Jacobsen G
J Cardiothorac Vasc Anesth; 1992 Dec; 6(6):705-10. PubMed ID: 1472668
[TBL] [Abstract][Full Text] [Related]
18. Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques.
Seo JH; Bae JY; Kim HJ; Hong DM; Jeon Y; Bahk JH
BMC Anesthesiol; 2015 Oct; 15():157. PubMed ID: 26511934
[TBL] [Abstract][Full Text] [Related]
19. [The importance of bronchoscopic anatomy for anesthesiologists].
Hoşten T; Topçu S
Tuberk Toraks; 2011; 59(4):416-26. PubMed ID: 22233317
[TBL] [Abstract][Full Text] [Related]
20. Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: a prospective study.
Klein U; Karzai W; Bloos F; Wohlfarth M; Gottschall R; Fritz H; Gugel M; Seifert A
Anesthesiology; 1998 Feb; 88(2):346-50. PubMed ID: 9477054
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]