BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 18561641)

  • 21. Proton beam radiotherapy versus fractionated stereotactic radiotherapy for uveal melanomas: A comparative study.
    Weber DC; Bogner J; Verwey J; Georg D; Dieckmann K; Escudé L; Caro M; Pötter R; Goitein G; Lomax AJ; Miralbell R
    Int J Radiat Oncol Biol Phys; 2005 Oct; 63(2):373-84. PubMed ID: 16168832
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Organ sparing by conformal avoidance intensity-modulated radiation therapy for anal cancer: dosimetric evaluation of coverage of pelvis and inguinal/femoral nodes.
    Chen YJ; Liu A; Tsai PT; Vora NL; Pezner RD; Schultheiss TE; Wong JY
    Int J Radiat Oncol Biol Phys; 2005 Sep; 63(1):274-81. PubMed ID: 16111597
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Characterization of a new MOSFET detector configuration for in vivo skin dosimetry.
    Scalchi P; Francescon P; Rajaguru P
    Med Phys; 2005 Jun; 32(6):1571-8. PubMed ID: 16013716
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Simplified low-dose-rate infant total body irradiation.
    Knutson N; Rao YJ; Yaddanapudi S; Perkins SM; Li HH
    Pract Radiat Oncol; 2017; 7(3):190-194. PubMed ID: 28094209
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity.
    Yao R; Bernard D; Turian J; Abrams RA; Sensakovic W; Fung HC; Chu JC
    Med Phys; 2012 Apr; 39(4):2239-48. PubMed ID: 22482645
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Analysis of various beamlet sizes for IMRT with 6 MV photons.
    Sohn JW; Dempsey JF; Suh TS; Low DA
    Med Phys; 2003 Sep; 30(9):2432-9. PubMed ID: 14528965
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Control algorithms for dynamic attenuators.
    Hsieh SS; Pelc NJ
    Med Phys; 2014 Jun; 41(6):061907. PubMed ID: 24877818
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A method for total skin electron treatment for infants.
    Earley L; Moeller J; O'Rear J; Leavitt DD
    Med Dosim; 1995; 20(4):243-8. PubMed ID: 8703318
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Total body irradiation, toward optimal individual delivery: dose evaluation with metal oxide field effect transistors, thermoluminescence detectors, and a treatment planning system.
    Bloemen-van Gurp EJ; Mijnheer BJ; Verschueren TA; Lambin P
    Int J Radiat Oncol Biol Phys; 2007 Nov; 69(4):1297-304. PubMed ID: 17881143
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Designing attenuators for total-body irradiation using virtual simulation.
    Corns R; Evans M; Olivares M; Dyke L; Podgorsak EB; Freeman CR
    Med Dosim; 2000; 25(1):27-31. PubMed ID: 10751716
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A motion phantom study on helical tomotherapy: the dosimetric impacts of delivery technique and motion.
    Kanagaki B; Read PW; Molloy JA; Larner JM; Sheng K
    Phys Med Biol; 2007 Jan; 52(1):243-55. PubMed ID: 17183139
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification.
    Kirov AS; Caravelli G; Palm A; Chui C; LoSasso T
    Med Phys; 2006 Oct; 33(10):3690-9. PubMed ID: 17089835
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Monte Carlo optimization of total body irradiation in a phantom and patient geometry.
    Chakarova R; Müntzing K; Krantz M; Hedin E; Hertzman S
    Phys Med Biol; 2013 Apr; 58(8):2461-9. PubMed ID: 23514805
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Commissioning Varian enhanced dynamic wedge in the PINNACLE treatment planning system using Gafchromic EBT film.
    Fontanarosa D; Orlandini LC; Andriani I; Bernardi L
    Med Phys; 2009 Oct; 36(10):4504-10. PubMed ID: 19928081
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy.
    Arnfield MR; Otto K; Aroumougame VR; Alkins RD
    Med Phys; 2005 Jan; 32(1):12-8. PubMed ID: 15719949
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dose compensation of the total body irradiation therapy.
    Lin JP; Chu TC; Liu MT
    Appl Radiat Isot; 2001 Nov; 55(5):623-30. PubMed ID: 11573795
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Combined modulated electron and photon beams planned by a Monte-Carlo-based optimization procedure for accelerated partial breast irradiation.
    Palma BA; Sánchez AU; Salguero FJ; Arráns R; Sánchez CM; Zurita AW; Hermida MI; Leal A
    Phys Med Biol; 2012 Mar; 57(5):1191-202. PubMed ID: 22330241
    [TBL] [Abstract][Full Text] [Related]  

  • 38. On the validity of density overrides for VMAT lung SBRT planning.
    Wiant D; Vanderstraeten C; Maurer J; Pursley J; Terrell J; Sintay BJ
    Med Phys; 2014 Aug; 41(8):081707. PubMed ID: 25086517
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Implementation of a water compensator for total body irradiation.
    Gallina P; Rosati G; Rossi A
    IEEE Trans Biomed Eng; 2005 Oct; 52(10):1741-7. PubMed ID: 16235659
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Rapid radiographic film calibration for IMRT verification using automated MLC fields.
    Childress NL; Dong L; Rosen II
    Med Phys; 2002 Oct; 29(10):2384-90. PubMed ID: 12408313
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.