BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

353 related articles for article (PubMed ID: 18561672)

  • 1. Single and dual energy attenuation correction in PET/CT in the presence of iodine based contrast agents.
    Rehfeld NS; Heismann BJ; Kupferschläger J; Aschoff P; Christ G; Pfannenberg AC; Pichler BJ
    Med Phys; 2008 May; 35(5):1959-69. PubMed ID: 18561672
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging.
    Kinahan PE; Alessio AM; Fessler JA
    Technol Cancer Res Treat; 2006 Aug; 5(4):319-27. PubMed ID: 16866562
    [TBL] [Abstract][Full Text] [Related]  

  • 3. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.
    Kinahan PE; Hasegawa BH; Beyer T
    Semin Nucl Med; 2003 Jul; 33(3):166-79. PubMed ID: 12931319
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative positron emission tomography imaging in the presence of iodinated contrast media using electron density quantifications from dual-energy computed tomography.
    Shapira N; Scheuermann J; Perkins AE; Kim J; Liu LP; Karp JS; Noël PB
    Med Phys; 2021 Jan; 48(1):273-286. PubMed ID: 33170953
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dual energy CT for attenuation correction with PET/CT.
    Xia T; Alessio AM; Kinahan PE
    Med Phys; 2014 Jan; 41(1):012501. PubMed ID: 24387525
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correction for oral contrast artifacts in CT attenuation-corrected PET images obtained by combined PET/CT.
    Nehmeh SA; Erdi YE; Kalaigian H; Kolbert KS; Pan T; Yeung H; Squire O; Sinha A; Larson SM; Humm JL
    J Nucl Med; 2003 Dec; 44(12):1940-4. PubMed ID: 14660720
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effective methods to correct contrast agent-induced errors in PET quantification in cardiac PET/CT.
    Büther F; Stegger L; Dawood M; Range F; Schäfers M; Fischbach R; Wichter T; Schober O; Schäfers KP
    J Nucl Med; 2007 Jul; 48(7):1060-8. PubMed ID: 17574981
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET.
    Ay MR; Zaidi H
    Eur J Nucl Med Mol Imaging; 2006 Nov; 33(11):1301-13. PubMed ID: 16622710
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Method for transforming CT images for attenuation correction in PET/CT imaging.
    Carney JP; Townsend DW; Rappoport V; Bendriem B
    Med Phys; 2006 Apr; 33(4):976-83. PubMed ID: 16696474
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exact dual energy material decomposition from inconsistent rays (MDIR).
    Maass C; Meyer E; Kachelriess M
    Med Phys; 2011 Feb; 38(2):691-700. PubMed ID: 21452706
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel energy mapping approach for CT-based attenuation correction in PET.
    Teimourian B; Ay MR; Zafarghandi MS; Ghafarian P; Ghadiri H; Zaidi H
    Med Phys; 2012 Apr; 39(4):2078-89. PubMed ID: 22482629
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computed tomography-based attenuation correction in neurological positron emission tomography: evaluation of the effect of the X-ray tube voltage on quantitative analysis.
    Reza Ay M; Zaidi H
    Nucl Med Commun; 2006 Apr; 27(4):339-46. PubMed ID: 16531919
    [TBL] [Abstract][Full Text] [Related]  

  • 13. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients.
    Berthelsen AK; Holm S; Loft A; Klausen TL; Andersen F; Højgaard L
    Eur J Nucl Med Mol Imaging; 2005 Oct; 32(10):1167-75. PubMed ID: 15909196
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of time-of-flight PET on quantification errors in MR imaging-based attenuation correction.
    Mehranian A; Zaidi H
    J Nucl Med; 2015 Apr; 56(4):635-41. PubMed ID: 25745090
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of MR surface coils on PET quantification.
    MacDonald LR; Kohlmyer S; Liu C; Lewellen TK; Kinahan PE
    Med Phys; 2011 Jun; 38(6):2948-56. PubMed ID: 21815368
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cine CT for attenuation correction in cardiac PET/CT.
    Alessio AM; Kohlmyer S; Branch K; Chen G; Caldwell J; Kinahan P
    J Nucl Med; 2007 May; 48(5):794-801. PubMed ID: 17475969
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cause and magnitude of the error induced by oral CT contrast agent in CT-based attenuation correction of PET emission studies.
    Dizendorf E; Hany TF; Buck A; von Schulthess GK; Burger C
    J Nucl Med; 2003 May; 44(5):732-8. PubMed ID: 12732674
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Region-of-interest material decomposition from truncated energy-resolved CT.
    Schmidt TG; Pektas F
    Med Phys; 2011 Oct; 38(10):5657-66. PubMed ID: 21992382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Attenuation correction for a combined 3D PET/CT scanner.
    Kinahan PE; Townsend DW; Beyer T; Sashin D
    Med Phys; 1998 Oct; 25(10):2046-53. PubMed ID: 9800714
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Integrated whole-body PET/MR hybrid imaging: clinical experience.
    Quick HH; von Gall C; Zeilinger M; Wiesmüller M; Braun H; Ziegler S; Kuwert T; Uder M; Dörfler A; Kalender WA; Lell M
    Invest Radiol; 2013 May; 48(5):280-9. PubMed ID: 23442775
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.