These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 18562373)

  • 1. Keeping osteocytes alive: a comparison of drilling and hammering k-wires into bone.
    Franssen BB; van Diest PJ; Schuurman AH; Kon M
    J Hand Surg Eur Vol; 2008 Jun; 33(3):363-8. PubMed ID: 18562373
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Drilling K-wires, what about the osteocytes? An experimental study in rabbits.
    Franssen BB; van Diest PJ; Schuurman AH; Kon M
    Arch Orthop Trauma Surg; 2008 Jan; 128(1):83-7. PubMed ID: 17598116
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hammering versus drilling of sharp and obtuse trocar-point k-wires.
    Franssen BB; Schuurman AH; Mink Van Der Molen AB; Kon M
    J Hand Surg Eur Vol; 2009 Apr; 34(2):215-8. PubMed ID: 19282409
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Insertion of K-wires by hammer generates less heat. A study of drilling and hammering K-wires into bone.
    Zegunis V; Toksvig-Larsen S; Tikuisis R
    Acta Orthop Scand; 1993 Oct; 64(5):592-4. PubMed ID: 8237332
    [TBL] [Abstract][Full Text] [Related]  

  • 5. One century of Kirschner wires and Kirschner wire insertion techniques: a historical review.
    Franssen BB; Schuurman AH; Van der Molen AM; Kon M
    Acta Orthop Belg; 2010 Feb; 76(1):1-6. PubMed ID: 20306956
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of lateral rotation splinting on lower extremity bone growth: an in vivo study in rabbits.
    Barlow DW; Staheli LT
    J Pediatr Orthop; 1991; 11(5):583-7. PubMed ID: 1918343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hammering K-wires is superior to drilling with irrigation.
    Franssen BB; Schuurman AH; Brouha PC; Kon M
    Hand (N Y); 2009 Jun; 4(2):108-12. PubMed ID: 19082666
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Notched K-wire for low thermal damage bone drilling.
    Liu Y; Belmont B; Wang Y; Tai B; Holmes J; Shih A
    Med Eng Phys; 2017 Jul; 45():25-33. PubMed ID: 28462826
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of cortical bone drilling induced heat production among common drilling tools.
    Palmisano AC; Tai BL; Belmont B; Irwin TA; Shih A; Holmes JR
    J Orthop Trauma; 2015 May; 29(5):e188-93. PubMed ID: 25233167
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Early cortical bone healing around loaded titanium implants: a histological study in the rabbit.
    Slaets E; Naert I; Carmeliet G; Duyck J
    Clin Oral Implants Res; 2009 Feb; 20(2):126-34. PubMed ID: 19191791
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Temperature Rise in Kirschner Wires Inserted Using Two Drilling Methods: Forward and Oscillation.
    Anderson SR; Inceoglu S; Wongworawat MD
    Hand (N Y); 2018 Jul; 13(4):423-427. PubMed ID: 28511590
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stability changes after cryosurgery in long tubular bones in correlation to histological results: an animal trial.
    Popken F; Michael JW; Zarghooni K; Sobottke R; Kasper HU; Blaecker D; Niehoff A; Emrich F; Eysel P
    Arch Orthop Trauma Surg; 2009 Jun; 129(6):857-62. PubMed ID: 18651109
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Heat Generation in Unidirectional Versus Oscillatory Modes During K-Wire Insertion in Bone.
    Luo Y; Chen L; Finney FT; Park DW; Talusan PG; Holmes JR; Shih AJ
    J Orthop Res; 2019 Sep; 37(9):1903-1909. PubMed ID: 31081555
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Percutaneous pinning of distal radius fractures: an anatomic study demonstrating the proximity of K-wires to structures at risk.
    Chia B; Catalano LW; Glickel SZ; Barron OA; Meier K
    J Hand Surg Am; 2009; 34(6):1014-20. PubMed ID: 19643288
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical comparisons of unidirectional and bidirectional Kirschner-wire insertion.
    Zohman GL; Tsenter M; Kabo JM; Meals RA
    Clin Orthop Relat Res; 1992 Nov; (284):299-302. PubMed ID: 1395308
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analysis and estimation of cutting-temperature distribution during end milling in relation to orthopedic surgery.
    Sugita N; Osa T; Mitsuishi M
    Med Eng Phys; 2009 Jan; 31(1):101-7. PubMed ID: 18556234
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hollow Notched K-Wires for Bone Drilling With Through-Tool Cooling.
    Luo Y; Chen L; Shih AJ
    J Orthop Res; 2019 Nov; 37(11):2297-2306. PubMed ID: 31332811
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of circumferential bands on cortical vascularity and viability.
    Kirby BM; Wilson JW
    J Orthop Res; 1991 Mar; 9(2):174-9. PubMed ID: 1992066
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of bone drilling on local temperature and bone regeneration: an in vivo study.
    Karaca F; Aksakal B; Köm M
    Acta Orthop Traumatol Turc; 2014; 48(3):326-32. PubMed ID: 24901925
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The effects of continuous passive motion on tendon-bone healing of the tendon autograft used for anterior cruciate ligament reconstruction in a rabbit model].
    Huang HS; Ao YF; Wang YJ; Li X
    Zhonghua Wai Ke Za Zhi; 2008 Jul; 46(14):1088-91. PubMed ID: 19094538
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.