  • 1. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms.
    Kowalski M; Ellenbogen KA; Wood MA; Friedman PL
    Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure.
    Spencker S; Coban N; Koch L; Schirdewan A; Müller D
    Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of pacing/defibrillator lead failure using device diagnostics and pacing maneuvers.
    Chung EH; Casavant D; John RM
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):547-9. PubMed ID: 19335868
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias.
    Occhetta E; Bortnik M; Magnani A; Francalacci G; Marino P
    Europace; 2006 Oct; 8(10):863-9. PubMed ID: 16916859
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multiple high lead impedances in an implantable-cardioverter defibrillator system: what is the mechanism?
    Ho RT
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1173-5. PubMed ID: 23594162
    [No Abstract]   [Full Text] [Related]  

  • 7. Early automatic remote detection of combined lead insulation defect and ICD damage.
    Neuzil P; Taborsky M; Holy F; Wallbrueck K
    Europace; 2008 May; 10(5):556-7. PubMed ID: 18227352
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Myopotentials leading to ventricular fibrillation detection after advisory defibrillator generator replacement.
    Eckart RE; Hruczkowski TW; Stevenson WG; Epstein LM
    Pacing Clin Electrophysiol; 2006 Nov; 29(11):1273-6. PubMed ID: 17100683
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inappropriate defibrillator shocks from depolarization--repolarization mismatch in a patient with hypertrophy cardiomyopathy.
    Kapa S; Curwin JH; Coyne RF; Winters SL
    Pacing Clin Electrophysiol; 2007 Nov; 30(11):1408-11. PubMed ID: 17976109
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noise, artifact, and oversensing related inappropriate ICD shock evaluation: ALTITUDE noise study.
    Powell BD; Asirvatham SJ; Perschbacher DL; Jones PW; Cha YM; Cesario DA; Cao M; Gilliam FR; Saxon LA
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):863-9. PubMed ID: 22519674
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks.
    Tzeis S; Andrikopoulos G; Kolb C; Vardas PE
    Europace; 2008 Nov; 10(11):1256-65. PubMed ID: 18708639
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead.
    Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M
    Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Spectrum of issues detected by an ICD diagnostic alert that utilizes far-field electrograms: Clinical implications.
    Koneru JN; Kaszala K; Bordachar P; Shehata M; Swerdlow C; Ellenbogen KA
    Heart Rhythm; 2015 May; 12(5):957-67. PubMed ID: 25640632
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Limitation of programmed alerts to predict ICD lead failures.
    Vlay SC
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):554-5. PubMed ID: 19335870
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An unusual mechanism causing inappropriate implantable cardioverter defibrillator shocks: transient reduction in R-wave amplitude.
    Baranchuk A; Ribas S; Divakaramenon S; Morillo CA
    Europace; 2007 Aug; 9(8):694-6. PubMed ID: 17478463
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sensing failure associated with the Medtronic Sprint Fidelis defibrillator lead.
    Kenigsberg DN; Mirchandani S; Dover AN; Kowalski M; Wood MA; Shepard RK; Kalahasty G; Stein KM; Markowitz SM; Iwai S; Shah BK; Lerman BB; Mittal S; Ellenbogen KA
    J Cardiovasc Electrophysiol; 2008 Mar; 19(3):270-4. PubMed ID: 18179527
    [TBL] [Abstract][Full Text] [Related]  

  • 20. T-wave oversensing in implantable cardiac defibrillators is due to technical failure of device sensing.
    Gilliam FR
    J Cardiovasc Electrophysiol; 2006 May; 17(5):553-6. PubMed ID: 16684033
    [TBL] [Abstract][Full Text] [Related]  