BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

817 related articles for article (PubMed ID: 18573045)

  • 1. Novel hemostatic devices in thyroid surgery: electrothermal bipolar vessel sealing system and harmonic scalpel.
    Manouras A; Markogiannakis HE; Kekis PB; Lagoudianakis EE; Fleming B
    Expert Rev Med Devices; 2008 Jul; 5(4):447-66. PubMed ID: 18573045
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation.
    Manouras A; Markogiannakis H; Koutras AS; Antonakis PT; Drimousis P; Lagoudianakis EE; Kekis P; Genetzakis M; Koutsoumanis K; Bramis I
    Am J Surg; 2008 Jan; 195(1):48-52. PubMed ID: 18082542
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemostasis in thyroid surgery: harmonic scalpel versus other techniques--a meta-analysis.
    Ecker T; Carvalho AL; Choe JH; Walosek G; Preuss KJ
    Otolaryngol Head Neck Surg; 2010 Jul; 143(1):17-25. PubMed ID: 20620614
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modified radical mastectomy with axillary dissection using the electrothermal bipolar vessel sealing system.
    Manouras A; Markogiannakis H; Genetzakis M; Filippakis GM; Lagoudianakis EE; Kafiri G; Filis K; Zografos GC
    Arch Surg; 2008 Jun; 143(6):575-80; discussion 581. PubMed ID: 18559751
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis.
    Matthews BD; Pratt BL; Backus CL; Kercher KW; Mostafa G; Lentzner A; Lipford EH; Sing RF; Heniford BT
    Am Surg; 2001 Sep; 67(9):901-6. PubMed ID: 11565773
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy.
    Manouras A; Lagoudianakis EE; Antonakis PT; Filippakis GM; Markogiannakis H; Kekis PB
    Head Neck; 2005 Nov; 27(11):959-62. PubMed ID: 16134183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Hemostasis and bleeding control in thyroid surgery using electrothermal system (Ligasure): our experience in 317 patients].
    Ashkenazi D; Mazzawi S; Rakover Y
    Harefuah; 2006 Aug; 145(8):561-4, 632, 631. PubMed ID: 16983836
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: a meta-analysis.
    Macario A; Dexter F; Sypal J; Cosgriff N; Heniford BT
    Surg Innov; 2008 Dec; 15(4):284-91. PubMed ID: 18945705
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrothermal bipolar vessel sealing system (LigaSure) for hemostasis during thyroid surgery: a comprehensive review.
    Butskiy O; Wiseman SM
    Expert Rev Med Devices; 2013 May; 10(3):389-410. PubMed ID: 23668710
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy.
    Pons Y; Gauthier J; Ukkola-Pons E; Clément P; Roguet E; Poncet JL; Conessa C
    Otolaryngol Head Neck Surg; 2009 Oct; 141(4):496-501. PubMed ID: 19786219
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparative study of an electrothermal bipolar vessel sealing system (LigaSure®), a harmonic curved shears (Harmonic Focus™), and traditional technique in total thyroidectomy.
    Bove A; Bongarzoni G; Palone G; Di Renzo R; Di Nicola M; Corradetti L; Corbellini L
    Am Surg; 2010 Jul; 76(7):E94-6. PubMed ID: 21683011
    [No Abstract]   [Full Text] [Related]  

  • 12. The use of a harmonic scalpel in thyroid surgery: report of a 3-year experience.
    Koutsoumanis K; Koutras AS; Drimousis PG; Stamou KM; Theodorou D; Katsaragakis S; Bramis J
    Am J Surg; 2007 Jun; 193(6):693-6. PubMed ID: 17512278
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Comparison of conventional technique, Ligasure Precise and Harmonic Focus in total thyroidectomy].
    Di Rienzo RM; Bove A; Bongarzoni G; Palone G; Corradetti L; Corbellini L
    G Chir; 2010; 31(6-7):296-8. PubMed ID: 20646375
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of the harmonic scalpel in thyroidectomy.
    Parker DJ; Krupa K; Esler R; Vujovic P; Bennett IC
    ANZ J Surg; 2009 Jun; 79(6):476-80. PubMed ID: 19566873
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Surgical treatment of rhinophyma with the ultrasonic scalpel (Ultracision Harmonic Scalpel)].
    Metternich FU; Wenzel S; Sagowski C; Jäkel K; Koch U
    Laryngorhinootologie; 2003 Feb; 82(2):132-7. PubMed ID: 12624844
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prospective, randomized, controlled clinical trial of a novel matrix hemostatic sealant in children undergoing adenoidectomy.
    Mathiasen RA; Cruz RM
    Otolaryngol Head Neck Surg; 2004 Nov; 131(5):601-5. PubMed ID: 15523433
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safety and efficacy of the electrothermal bipolar vessel sealer in trauma.
    Hope WW; Burns JM; Newcomb WL; Heniford BT; Sing RF
    Injury; 2009 May; 40(5):564-6. PubMed ID: 18490017
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Preliminary results for superficial parotidectomy using the ultrasonically activated scalpel (Ultracision Harmonic Scalpel)].
    Metternich FU; Sagowski C; Wenzel S; Jäkel T; Leuwer R; Koch U
    Laryngorhinootologie; 2003 Jul; 82(7):514-9. PubMed ID: 12886500
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies.
    Garas G; Okabayashi K; Ashrafian H; Shetty K; Palazzo F; Tolley N; Darzi A; Athanasiou T; Zacharakis E
    Thyroid; 2013 Sep; 23(9):1138-50. PubMed ID: 23470035
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thyroidectomy Hemostasis.
    Smith RB; Coughlin A
    Otolaryngol Clin North Am; 2016 Jun; 49(3):727-48. PubMed ID: 27267022
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 41.