BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 18573437)

  • 21. Bioprosthetic replacement of the ascending thoracic aorta: what are the options?
    Kirsch ME; Ooka T; Zannis K; Deux JF; Loisance DY
    Eur J Cardiothorac Surg; 2009 Jan; 35(1):77-82. PubMed ID: 18952452
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Early hemodynamic performance of the BioValsalva valved conduit after aortic root replacement.
    Badiu CC; Deutsch MA; Bleiziffer S; Krane M; Hettich I; Voss B; Mazzitelli D; Lange R
    J Heart Valve Dis; 2014 Jan; 23(1):97-104. PubMed ID: 24779335
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Early results of a modified biological valved conduit for the Bentall procedure.
    Sirajuddin S; Wang CK; Al-Abri Q; Ridwan K; Hatzakorzian R; Lachapelle K; De Varennes B; Shum-Tim D
    J Card Surg; 2019 Jun; 34(6):412-418. PubMed ID: 30995341
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Seven-year performance of the Edwards Prima Plus stentless valve with the intact non-coronary sinus technique.
    Luciani GB; Viscardi F; Cresce GD; Faggian G; Mazzucco A
    J Card Surg; 2008; 23(3):221-6. PubMed ID: 18435636
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Reversed root for entirely biological aortic valve and ascending aorta replacement in a patient with endocarditis and mediastinitis.
    Albes JM; Claus T
    Thorac Cardiovasc Surg; 2011 Jun; 59(4):247-8. PubMed ID: 21394712
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Valved stentless composite graft: clinical outcomes and hemodynamic characteristics.
    Urbanski PP; Diegeler A; Siebel A; Zacher M; Hacker RW
    Ann Thorac Surg; 2003 Feb; 75(2):467-71. PubMed ID: 12607655
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].
    Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Aortic root replacement with a stentless bioprosthesis in osteogenesis imperfecta.
    Wakiyama H; Okada Y; Kitamura A; Imai Y
    J Heart Valve Dis; 2008 Mar; 17(2):197-9. PubMed ID: 18512491
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Non-anastomotic rupture of the Valsalva graft 6 years after undergoing the Bentall procedure.
    Oshima H; Abe T; Narita Y; Usui A
    Interact Cardiovasc Thorac Surg; 2016 Oct; 23(4):668-70. PubMed ID: 27324732
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Modified Bentall operation with a novel biologic valved conduit.
    Stewart AS; Takayama H; Smith CR
    Ann Thorac Surg; 2010 Mar; 89(3):938-41. PubMed ID: 20172157
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Chronic dissection and aneurysmal dilatation of a BioValsalva conduit.
    Yigzaw YA; Lau KK; Baig K; Uppal R
    Ann Thorac Surg; 2013 Jul; 96(1):298-300. PubMed ID: 23816079
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Composite stentless valve with graft extension for combined replacement of the aortic valve, root and ascending aorta.
    Byrne JG; Mihaljevic T; Lipson WE; Smith B; Fox JA; Aranki SF
    Eur J Cardiothorac Surg; 2001 Aug; 20(2):252-6. PubMed ID: 11463540
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Late disruption of a Freestyle stentless bioprosthesis used for repair of sinus of Valsalva aneurysm of noncoronary cusp.
    Takami Y; Masumoto H; Fyfe-Kirschner B
    Ann Thorac Surg; 2007 Jun; 83(6):2210-3. PubMed ID: 17532431
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Critical role of the sinuses of Valsalva in the durability of valved conduits.
    Kumar SP; Kumar MN; Ali ML; Becker A; Duran CM
    J Heart Valve Dis; 1996 Mar; 5(2):160-7. PubMed ID: 8665008
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Totally biological composite aortic stentless valved conduit for aortic root replacement: 10-year experience.
    GaliƱanes M; Meduoye A; Ferreira I; Sosnowski A
    J Cardiothorac Surg; 2011 Jun; 6():86. PubMed ID: 21699696
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stentless porcine valves in the right ventricular outflow tract: improved durability?
    Hawkins JA; Sower CT; Lambert LM; Kouretas PC; Burch PT; Kaza AK; Puchalski MD; Yetman AT
    Eur J Cardiothorac Surg; 2009 Apr; 35(4):600-4; discussion 604-5. PubMed ID: 19211257
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reoperation for early failure of a freestyle bioprosthesis using a full root technique.
    Kitamura A; Handa N; Shomura Y; Wakiyama H; Shinka M; Fujiwara H; Nasu M; Tanabe K; Tani T; Morioka S; Okada Y
    J Heart Valve Dis; 2007 May; 16(3):275-7. PubMed ID: 17578047
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Aortic root replacement with a new stentless aortic valve xenograft conduit: preliminary hemodynamic and clinical results.
    Carrel TP; Berdat P; Englberger L; Eckstein F; Immer F; Seiler C; Kipfer B; Schmidli J
    J Heart Valve Dis; 2003 Nov; 12(6):752-7. PubMed ID: 14658817
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Replacement of the ascending aorta and aortic valve with a valved stentless composite graft.
    Urbanski PP
    Ann Thorac Surg; 1999 May; 67(5):1501-2. PubMed ID: 10355450
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Reoperation due to failure of a Freestyle bioprosthesis].
    Abe T; Kawahito K; Naganuma H; Hanai M; Mashiko K; Hashimoto K
    Kyobu Geka; 2008 Jul; 61(7):545-8. PubMed ID: 18616098
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.