93 related articles for article (PubMed ID: 18578664)
1. Accuracy of urinary dipstick testing for pH manipulation therapy.
Desai RA; Assimos DG
J Endourol; 2008 Jun; 22(6):1367-70. PubMed ID: 18578664
[TBL] [Abstract][Full Text] [Related]
2. Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?
Abbott JE; Miller DL; Shi W; Wenzler D; Elkhoury FF; Patel ND; Sur RL
Investig Clin Urol; 2017 Sep; 58(5):378-382. PubMed ID: 28868511
[TBL] [Abstract][Full Text] [Related]
3. The diagnostic performance of human urinary dipsticks to estimate urine pH, specific gravity (SpG), and protein in horses: are they reliable?
Hekmatynia F; Eskandarzadeh N; Imani M; Rezaei M; Zamani-Ahmadmahmudi M
BMC Vet Res; 2019 Jul; 15(1):242. PubMed ID: 31300054
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of the spot urinary microalbumin:creatinine ratio and visual dipsticks in hypertensive pregnant women.
Gangaram R; Naicker M; Moodley J
Eur J Obstet Gynecol Reprod Biol; 2009 Jun; 144(2):146-8. PubMed ID: 19371998
[TBL] [Abstract][Full Text] [Related]
5. Accuracy and precision of urinary pH determinations using two commercially available dipsticks.
James GP; Bee DE; Fuller JB
Am J Clin Pathol; 1978 Sep; 70(3):368-74. PubMed ID: 30274
[TBL] [Abstract][Full Text] [Related]
6. Comparative study between a medical device and reagent dipsticks in measuring pH.
Angerri O; Pascual D; Haro J; Fernández X; Chiganças V; Garganta R; Cuñé J
Arch Esp Urol; 2020 Jul; 73(6):546-553. PubMed ID: 32633250
[TBL] [Abstract][Full Text] [Related]
7. Influence of urine pH on accurate urinary protein determination in Sprague-Dawley rats.
Reagan WJ; VanderLind B; Shearer A; Botts S
Vet Clin Pathol; 2007 Mar; 36(1):73-8. PubMed ID: 17311198
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of a Portable Urinary pH Meter and Reagent Strips.
De Coninck V; Keller EX; Rodríguez-Monsalve M; Doizi S; Audouin M; Haymann JP; Traxer O
J Endourol; 2018 Jul; 32(7):647-652. PubMed ID: 29699425
[TBL] [Abstract][Full Text] [Related]
9. Performance characteristics of urine dipsticks stored in open containers.
Gallagher EJ; Schwartz E; Weinstein RS
Am J Emerg Med; 1990 Mar; 8(2):121-3. PubMed ID: 2302279
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of urine pH testing in a regional metabolic renal clinic: is the dipstick accurate enough?
Kwong T; Robinson C; Spencer D; Wiseman OJ; Karet Frankl FE
Urolithiasis; 2013 Apr; 41(2):129-32. PubMed ID: 23435644
[TBL] [Abstract][Full Text] [Related]
11. Comparison between the urine dipstick and the pH-meter to assess urine pH in sheep and dogs.
Athanasiou LV; Katsoulos PD; Katsogiannou EG; Polizopoulou ZS; Diamantaki M; Kamatsos C; Christodoulopoulos G
Vet Clin Pathol; 2018 Jun; 47(2):284-288. PubMed ID: 29406602
[TBL] [Abstract][Full Text] [Related]
12. Comparison of urine dipsticks with quantitative methods for microalbuminuria.
Pugia MJ; Lott JA; Clark LW; Parker DR; Wallace JF; Willis TW
Eur J Clin Chem Clin Biochem; 1997 Sep; 35(9):693-700. PubMed ID: 9352232
[TBL] [Abstract][Full Text] [Related]
13. Discordance between urine pH measured by dipstick and pH meter: implications for methotrexate administration protocols.
Wockenfus AM; Koch CD; Conlon PM; Sorensen LD; Cambern KL; Chihak AJ; Zmolek JA; Petersen AE; Burns BE; Lieske JC; Karon BS
Clin Biochem; 2013 Jan; 46(1-2):152-4. PubMed ID: 23103706
[TBL] [Abstract][Full Text] [Related]
14. The accuracy of urine dipsticks as a screening test for proteinuria in hypertensive disorders of pregnancy.
Gangaram R; Ojwang PJ; Moodley J; Maharaj D
Hypertens Pregnancy; 2005; 24(2):117-23. PubMed ID: 16036396
[TBL] [Abstract][Full Text] [Related]
15. Diagnostic accuracy of urine dipsticks for detection of albuminuria in the general community.
White SL; Yu R; Craig JC; Polkinghorne KR; Atkins RC; Chadban SJ
Am J Kidney Dis; 2011 Jul; 58(1):19-28. PubMed ID: 21411199
[TBL] [Abstract][Full Text] [Related]
16. A study on the reliability of dipstick urinalysis.
Bonnardeaux A; Somerville P; Kaye M
Clin Nephrol; 1994 Mar; 41(3):167-72. PubMed ID: 8187361
[TBL] [Abstract][Full Text] [Related]
17. The diagnostic accuracy of the rapid dipstick test to predict asymptomatic urinary tract infection of pregnancy.
Eigbefoh JO; Isabu P; Okpere E; Abebe J
J Obstet Gynaecol; 2008 Jul; 28(5):490-5. PubMed ID: 18850421
[TBL] [Abstract][Full Text] [Related]
18. Dipstick testing of urine--can it replace urine microscopy?
Morrison MC; Lum G
Am J Clin Pathol; 1986 May; 85(5):590-4. PubMed ID: 3754687
[TBL] [Abstract][Full Text] [Related]
19. The role of dipsticks in the diagnosis of urinary tract infection.
Murphy LC; Keane CT; Rees JP
Ir Med J; 1989 Jun; 82(2):74-6. PubMed ID: 2759829
[TBL] [Abstract][Full Text] [Related]
20. The sensitivity and specificity of a urine leukocyte esterase dipstick test for the diagnosis of urinary tract infection in the outpatient clinic of Rajavithi Hospital.
Laosu-angkoon S
J Med Assoc Thai; 2013 Jul; 96(7):849-53. PubMed ID: 24319857
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]