251 related articles for article (PubMed ID: 18585303)
1. Selectivity of solid-contact Ag potentiometric sensors based on thiacalix[4]arene derivatives.
Evtugyn GA; Stoikov II; Belyakova SV; Stoikova EE; Shamagsumova RV; Zhukov AY; Antipin IS; Budnikov HC
Talanta; 2008 Jul; 76(2):441-7. PubMed ID: 18585303
[TBL] [Abstract][Full Text] [Related]
2. Ag selective electrode based on glassy carbon electrode covered with polyaniline and thiacalix[4]arene as neutral carrier.
Evtugyn GA; Stoikov II; Beljyakova SV; Shamagsumova RV; Stoikova EE; Zhukov AY; Antipin IS; Budnikov HC
Talanta; 2007 Mar; 71(4):1720-7. PubMed ID: 19071514
[TBL] [Abstract][Full Text] [Related]
3. An NBD-armed thiacalix[4]arene-derived colorimetric and fluorometric chemosensor for Ag+: a metal-ligand receptor of anions.
Fu Y; Mu L; Zeng X; Zhao JL; Redshaw C; Ni XL; Yamato T
Dalton Trans; 2013 Mar; 42(10):3552-60. PubMed ID: 23282954
[TBL] [Abstract][Full Text] [Related]
4. Potentiometric evaluation of calix[4]arene anion receptors in membrane electrodes: phosphate detection.
Kivlehan F; Mace WJ; Moynihan HA; Arrigan DW
Anal Chim Acta; 2007 Feb; 585(1):154-60. PubMed ID: 17386660
[TBL] [Abstract][Full Text] [Related]
5. A new Hg(2+) -selective fluorescent sensor based on a 1,3-alternate thiacalix[4]arene anchored with four 8-quinolinoloxy groups.
Praveen L; Ganga VB; Thirumalai R; Sreeja T; Reddy ML; Varma RL
Inorg Chem; 2007 Aug; 46(16):6277-82. PubMed ID: 17608414
[TBL] [Abstract][Full Text] [Related]
6. A mercury(II) selective sensor based on N,N'-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples.
Abu-Shawish HM
J Hazard Mater; 2009 Aug; 167(1-3):602-8. PubMed ID: 19195781
[TBL] [Abstract][Full Text] [Related]
7. Flow and batch systems for copper(II) potentiometric sensing.
Gismera MJ; Sevilla MT; Procopio JR
Talanta; 2007 Nov; 74(2):190-7. PubMed ID: 18371629
[TBL] [Abstract][Full Text] [Related]
8. Cascade and commutative self-assembles of nanoscale three-component systems controlled by the conformation of thiacalix[4]arene.
Yushkova EA; Stoikov II; Puplampu JB; Antipin IS; Konovalov AI
Langmuir; 2011 Dec; 27(23):14053-64. PubMed ID: 21988372
[TBL] [Abstract][Full Text] [Related]
9. Thiacalix[4]arene based reconfigurable molecular switches: set-reset memorized sequential device.
Kumar M; Kumar R; Bhalla V
Org Biomol Chem; 2011 Dec; 9(24):8237-45. PubMed ID: 22020930
[TBL] [Abstract][Full Text] [Related]
10. Exceptionally long-lived luminescence emitted from Tb(III) ion caged in an Ag(I)-Tb(III)-thiacalix[4]arene supramolecular complex in water.
Iki N; Ohta M; Horiuchi T; Hoshino H
Chem Asian J; 2008 May; 3(5):849-53. PubMed ID: 18386266
[TBL] [Abstract][Full Text] [Related]
11. Synthesis and characterization of monoazathiacrown ethers as ionophores for polymeric membrane silver-selective electrodes.
Zhang J; Ding J; Yin T; Hu X; Yu S; Qin W
Talanta; 2010 May; 81(3):1056-62. PubMed ID: 20298893
[TBL] [Abstract][Full Text] [Related]
12. A novel cobalt(II)-selective potentiometric sensor based on p-(4-n-butylphenylazo)calix[4]arene.
Kumar P; Shim YB
Talanta; 2009 Jan; 77(3):1057-62. PubMed ID: 19064091
[TBL] [Abstract][Full Text] [Related]
13. Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact.
Ibrahim H; Issa YM; Abu-Shawish HM
J Pharm Biomed Anal; 2007 May; 44(1):8-15. PubMed ID: 17383844
[TBL] [Abstract][Full Text] [Related]
14. Electrochemical sensing of iron (III) by using rhodamine dimer as an electroactive material.
Kamal A; Sharma N; Bhalla V; Kumar M; Mahajan RK
Talanta; 2014 Oct; 128():422-7. PubMed ID: 25059181
[TBL] [Abstract][Full Text] [Related]
15. Band intensity in the IR spectra and conformations of calix[4]arene and thiacalix[4]arene.
Furer VL; Borisoglebskaya EI; Kovalenko VI
Spectrochim Acta A Mol Biomol Spectrosc; 2005 Jan; 61(1-2):355-9. PubMed ID: 15556460
[TBL] [Abstract][Full Text] [Related]
16. p-tert-Butyl thiacalix[4]arenes functionalized with amide and hydrazide groups at the lower rim in cone, partial cone, and 1,3-alternate conformations are "smart" building blocks for constructing nanosized structures with metal cations of s-, p-, and d-elements in the organic phase.
Yushkova EA; Stoikov II
Langmuir; 2009 May; 25(9):4919-28. PubMed ID: 19239249
[TBL] [Abstract][Full Text] [Related]
17. Solid Contact Potentiometric Sensors Based on a New Class of Ionic Liquids on Thiacalixarene Platform.
Padnya PL; Porfireva AV; Evtugyn GA; Stoikov II
Front Chem; 2018; 6():594. PubMed ID: 30538984
[TBL] [Abstract][Full Text] [Related]
18. Thiacalix[4]arene based fluorescent probe for sensing and imaging of Fe3+ ions.
Kumar M; Kumar R; Bhalla V; Sharma PR; Kaur T; Qurishi Y
Dalton Trans; 2012 Jan; 41(2):408-12. PubMed ID: 22095026
[TBL] [Abstract][Full Text] [Related]
19. Highly selective potentiometric determination of mercury(II) ions using 1-furan-2-yl-4-(4-nitrophenyl)-2-phenyl-5H-imidazole-3-oxide based membrane electrodes.
Mahajan RK; Puri RK; Marwaha A; Kaur I; Mahajan MP
J Hazard Mater; 2009 Aug; 167(1-3):237-43. PubMed ID: 19185990
[TBL] [Abstract][Full Text] [Related]
20. Potentiometric behaviour of ion selective electrodes based on iron porphyrins: the influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations.
Santos EM; Araújo AN; Couto CM; Montenegro MC
J Pharm Biomed Anal; 2006 Nov; 42(5):535-42. PubMed ID: 16842960
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]