These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

572 related articles for article (PubMed ID: 18586497)

  • 1. Development of an extraocular retinal prosthesis: evaluation of stimulation parameters in the cat.
    Chowdhury V; Morley JW; Coroneo MT
    J Clin Neurosci; 2008 Aug; 15(8):900-6. PubMed ID: 18586497
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stimulation of the retina with a multielectrode extraocular visual prosthesis.
    Chowdhury V; Morley JW; Coroneo MT
    ANZ J Surg; 2005 Aug; 75(8):697-704. PubMed ID: 16076336
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of extraocular electrodes for a retinal prosthesis using evoked potentials in cat visual cortex.
    Chowdhury V; Morley JW; Coroneo MT
    J Clin Neurosci; 2005 Jun; 12(5):574-9. PubMed ID: 16051097
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo electrical stimulation of rabbit retina with a microfabricated array: strategies to maximize responses for prospective assessment of stimulus efficacy and biocompatibility.
    Rizzo JF; Goldbaum S; Shahin M; Denison TJ; Wyatt J
    Restor Neurol Neurosci; 2004; 22(6):429-43. PubMed ID: 15798362
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thresholds for activation of rabbit retinal ganglion cells with a subretinal electrode.
    Jensen RJ; Rizzo JF
    Exp Eye Res; 2006 Aug; 83(2):367-73. PubMed ID: 16616739
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Visual cortex responses to single- and simultaneous multiple-electrode stimulation of the retina: implications for retinal prostheses.
    Shivdasani MN; Fallon JB; Luu CD; Cicione R; Allen PJ; Morley JW; Williams CE
    Invest Ophthalmol Vis Sci; 2012 Sep; 53(10):6291-300. PubMed ID: 22899754
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Focal activation of the feline retina via a suprachoroidal electrode array.
    Wong YT; Chen SC; Seo JM; Morley JW; Lovell NH; Suaning GJ
    Vision Res; 2009 Mar; 49(8):825-33. PubMed ID: 19272402
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility of extraocular stimulation for a retinal prosthesis.
    Chowdhury V; Morley JW; Coroneo MT
    Can J Ophthalmol; 2005 Oct; 40(5):563-72. PubMed ID: 16391619
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Surface stimulation of the brain with a prototype array for a visual cortex prosthesis.
    Chowdhury V; Morley JW; Coroneo MT
    J Clin Neurosci; 2004 Sep; 11(7):750-5. PubMed ID: 15337140
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit.
    Yamauchi Y; Franco LM; Jackson DJ; Naber JF; Ziv RO; Rizzo JF; Kaplan HJ; Enzmann V
    J Neural Eng; 2005 Mar; 2(1):S48-56. PubMed ID: 15876654
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in-vivo paradigm for the evaluation of stimulating electrodes for use with a visual prosthesis.
    Chowdhury V; Morley JW; Coroneo MT
    ANZ J Surg; 2004 May; 74(5):372-8. PubMed ID: 15144260
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The electrical stimulation of the retina by indwelling electrodes.
    Dawson WW; Radtke ND
    Invest Ophthalmol Vis Sci; 1977 Mar; 16(3):249-52. PubMed ID: 844981
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Visual cortex responses to suprachoroidal electrical stimulation of the retina: effects of electrode return configuration.
    Cicione R; Shivdasani MN; Fallon JB; Luu CD; Allen PJ; Rathbone GD; Shepherd RK; Williams CE
    J Neural Eng; 2012 Jun; 9(3):036009. PubMed ID: 22595310
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis.
    Shivdasani MN; Luu CD; Cicione R; Fallon JB; Allen PJ; Leuenberger J; Suaning GJ; Lovell NH; Shepherd RK; Williams CE
    J Neural Eng; 2010 Jun; 7(3):036008. PubMed ID: 20479521
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term histological and electrophysiological results of an inactive epiretinal electrode array implantation in dogs.
    Majji AB; Humayun MS; Weiland JD; Suzuki S; D'Anna SA; de Juan E
    Invest Ophthalmol Vis Sci; 1999 Aug; 40(9):2073-81. PubMed ID: 10440263
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrical stimulation of isolated retina with microwire glass electrodes.
    Johnson L; Perkins FK; O'Hearn T; Skeath P; Merritt C; Frieble J; Sadda S; Humayun M; Scribner D
    J Neurosci Methods; 2004 Aug; 137(2):265-73. PubMed ID: 15262070
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Activation zones in cat visual cortex evoked by electrical retina stimulation.
    Schanze T; Wilms M; Eger M; Hesse L; Eckhorn R
    Graefes Arch Clin Exp Ophthalmol; 2002 Nov; 240(11):947-54. PubMed ID: 12486519
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pathology of damaging electrical stimulation in the retina.
    Colodetti L; Weiland JD; Colodetti S; Ray A; Seiler MJ; Hinton DR; Humayun MS
    Exp Eye Res; 2007 Jul; 85(1):23-33. PubMed ID: 17531974
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrical stimulation in isolated rabbit retina.
    Shyu JS; Maia M; Weiland JD; Ohearn T; Chen SJ; Margalit E; Suzuki S; Humayun MS
    IEEE Trans Neural Syst Rehabil Eng; 2006 Sep; 14(3):290-8. PubMed ID: 17009488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vivo electrical stimulation of rabbit retina: effect of stimulus duration and electrical field orientation.
    Shah HA; Montezuma SR; Rizzo JF
    Exp Eye Res; 2006 Aug; 83(2):247-54. PubMed ID: 16750527
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.