These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 18591988)

  • 1. In Vivo EPR For Dosimetry.
    Swartz HM; Burke G; Coey M; Demidenko E; Dong R; Grinberg O; Hilton J; Iwasaki A; Lesniewski P; Kmiec M; Lo KM; Nicolalde RJ; Ruuge A; Sakata Y; Sucheta A; Walczak T; Williams BB; Mitchell C; Romanyukha A; Schauer DA
    Radiat Meas; 2007 Jul; 42(6-7):1075-1084. PubMed ID: 18591988
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation.
    Swartz HM; Iwasaki A; Walczak T; Demidenko E; Salikhov I; Khan N; Lesniewski P; Thomas J; Romanyukha A; Schauer D; Starewicz P
    Radiat Prot Dosimetry; 2006; 120(1-4):163-70. PubMed ID: 16644994
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurements of clinically significant doses of ionizing radiation using non-invasive in vivo EPR spectroscopy of teeth in situ.
    Swartz HM; Iwasaki A; Walczak T; Demidenko E; Salikov I; Lesniewski P; Starewicz P; Schauer D; Romanyukha A
    Appl Radiat Isot; 2005 Feb; 62(2):293-9. PubMed ID: 15607464
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo EPR tooth dosimetry for triage after a radiation event involving large populations.
    Williams BB; Flood AB; Salikhov I; Kobayashi K; Dong R; Rychert K; Du G; Schreiber W; Swartz HM
    Radiat Environ Biophys; 2014 May; 53(2):335-46. PubMed ID: 24711003
    [TBL] [Abstract][Full Text] [Related]  

  • 5. RENEB Inter-Laboratory Comparison 2021: Inter-Assay Comparison of Eight Dosimetry Assays.
    Port M; Barquinero JF; Endesfelder D; Moquet J; Oestreicher U; Terzoudi G; Trompier F; Vral A; Abe Y; Ainsbury L; Alkebsi L; Amundson SA; Badie C; Baeyens A; Balajee AS; Balázs K; Barnard S; Bassinet C; Beaton-Green LA; Beinke C; Bobyk L; Brochard P; Brzoska K; Bucher M; Ciesielski B; Cuceu C; Discher M; D Oca MC; Domínguez I; Doucha-Senf S; Dumitrescu A; Duy PN; Finot F; Garty G; Ghandhi SA; Gregoire E; Goh VST; Güçlü I; Hadjiiska L; Hargitai R; Hristova R; Ishii K; Kis E; Juniewicz M; Kriehuber R; Lacombe J; Lee Y; Lopez Riego M; Lumniczky K; Mai TT; Maltar-Strmečki N; Marrale M; Martinez JS; Marciniak A; Maznyk N; McKeever SWS; Meher PK; Milanova M; Miura T; Monteiro Gil O; Montoro A; Moreno Domene M; Mrozik A; Nakayama R; O'Brien G; Oskamp D; Ostheim P; Pajic J; Pastor N; Patrono C; Pujol-Canadell M; Prieto Rodriguez MJ; Repin M; Romanyukha A; Rößler U; Sabatier L; Sakai A; Scherthan H; Schüle S; Seong KM; Sevriukova O; Sholom S; Sommer S; Suto Y; Sypko T; Szatmári T; Takahashi-Sugai M; Takebayashi K; Testa A; Testard I; Tichy A; Triantopoulou S; Tsuyama N; Unverricht-Yeboah M; Valente M; Van Hoey O; Wilkins RC; Wojcik A; Wojewodzka M; Younghyun L; Zafiropoulos D; Abend M
    Radiat Res; 2023 Jun; 199(6):535-555. PubMed ID: 37310880
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Imaging tooth enamel using zero echo time (ZTE) magnetic resonance imaging.
    Rychert KM; Zhu G; Kmiec MM; Nemani VK; Williams BB; Flood AB; Swartz HM; Gimi B
    Proc SPIE Int Soc Opt Eng; 2015 Mar; 9417():. PubMed ID: 25914509
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of free radicals signal from dental resins on the radio-induced signal in teeth in EPR retrospective dosimetry.
    Levêque P; Desmet C; Dos Santos-Goncalvez AM; Beun S; Leprince JG; Leloup G; Gallez B
    PLoS One; 2013; 8(5):e62225. PubMed ID: 23704875
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiation dose reconstruction from L-band in vivo EPR spectroscopy of intact teeth: Comparison of methods.
    Demidenko E; Williams BB; Sucheta A; Dong R; Swartz HM
    Radiat Meas; 2007 Jul; 42(6-7):1089-1098. PubMed ID: 18591987
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Deployable In Vivo EPR Tooth Dosimeter for Triage After a Radiation Event Involving Large Populations.
    Williams BB; Dong R; Flood AB; Grinberg O; Kmiec M; Lesniewski PN; Matthews TP; Nicolalde RJ; Raynolds T; Salikhov IK; Swartz HM
    Radiat Meas; 2011 Sep; 46(9):772-777. PubMed ID: 21966241
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Standard technical specifications for methacholine chloride (Methacholine) bronchial challenge test (2023)].
    ; ;
    Zhonghua Jie He He Hu Xi Za Zhi; 2024 Feb; 47(2):101-119. PubMed ID: 38309959
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo EPR dosimetry of accidental exposures to radiation: experimental results indicating the feasibility of practical use in human subjects.
    Miyake M; Liu KJ; Walczak TM; Swartz HM
    Appl Radiat Isot; 2000 May; 52(5):1031-8. PubMed ID: 10836403
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Folic acid supplementation and malaria susceptibility and severity among people taking antifolate antimalarial drugs in endemic areas.
    Crider K; Williams J; Qi YP; Gutman J; Yeung L; Mai C; Finkelstain J; Mehta S; Pons-Duran C; Menéndez C; Moraleda C; Rogers L; Daniels K; Green P
    Cochrane Database Syst Rev; 2022 Feb; 2(2022):. PubMed ID: 36321557
    [TBL] [Abstract][Full Text] [Related]  

  • 13. FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY.
    Schreiber W; Petryakov SV; Kmiec MM; Feldman MA; Meaney PM; Wood VA; Boyle HK; Flood AB; Williams BB; Swartz HM
    Radiat Prot Dosimetry; 2016 Dec; 172(1-3):87-95. PubMed ID: 27421470
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Protocol for emergency EPR dosimetry in fingernails.
    Trompier F; Kornak L; Calas C; Romanyukha A; Leblanc B; Mitchell CA; Swartz HM; Clairand I
    Radiat Meas; 2007 Aug; 42(6-7):1085-1088. PubMed ID: 18163158
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electron Paramagnetic Resonance (EPR) Biodosimetry with Human Teeth: A Crucial Technique for Acute and Chronic Exposure Assessment.
    Ghimire L; Waller E
    Health Phys; 2024 May; 126(5):322-338. PubMed ID: 38526251
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Dose Spiking Technique for Measuring Low Doses in Deciduous Teeth Enamel Using EPR Spectroscopy for Retrospective and Accident Dosimetry.
    Ghimire L; Waller E
    Health Phys; 2023 Mar; 124(3):192-199. PubMed ID: 36719934
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In Vivo Verification of Electron Paramagnetic Resonance Biodosimetry Using Patients Undergoing Radiation Therapy Treatment.
    Draeger E; Roberts K; Decker RD; Bahar N; Wilson LD; Contessa J; Husain Z; Williams BB; Flood AB; Swartz HM; Carlson DJ
    Int J Radiat Oncol Biol Phys; 2024 May; 119(1):292-301. PubMed ID: 38072322
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation.
    Williams BB; Dong R; Nicolalde RJ; Matthews TP; Gladstone DJ; Demidenko E; Zaki BI; Salikhov IK; Lesniewski PN; Swartz HM
    Int J Radiat Biol; 2011 Aug; 87(8):766-75. PubMed ID: 21696339
    [TBL] [Abstract][Full Text] [Related]  

  • 19. External dose reconstruction in tooth enamel of Techa riverside residents.
    Shishkina EA; Volchkova AY; Timofeev YS; Fattibene P; Wieser A; Ivanov DV; Krivoschapov VA; Zalyapin VI; Della Monaca S; De Coste V; Degteva MO; Anspaugh LR
    Radiat Environ Biophys; 2016 Nov; 55(4):477-499. PubMed ID: 27600653
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of retrospective dose estimation, with fluorescence in situ hybridization (FISH), of six victims previously exposed to accidental ionizing radiation.
    Liu QJ; Lu X; Zhao XT; Feng JB; Lü YM; Jiang EH; Zhang SL; Chen DQ; Jia TZ; Liang L
    Mutat Res Genet Toxicol Environ Mutagen; 2014 Jan; 759():1-8. PubMed ID: 24246721
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.