These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
213 related articles for article (PubMed ID: 18592929)
41. Performance assessment of prosthetic heart valves using the energy index method. Souza-Campos F; Schoephoerster RT ASAIO J; 1996; 42(3):170-6. PubMed ID: 8725683 [TBL] [Abstract][Full Text] [Related]
42. Carpentier-Edwards Magna ease versus Magna valves: a comparison of in-vitro valve hydrodynamic performance. Dal Lin C; Bottio T; Buratto E; Tarzia V; Rizzoli G; Savona V; Gerosa G J Heart Valve Dis; 2012 Jan; 21(1):112-7. PubMed ID: 22474752 [TBL] [Abstract][Full Text] [Related]
43. Aortic valve-in-valve implantation: impact of transcatheter- bioprosthesis size mismatch. Azadani AN; Jaussaud N; Matthews PB; Chuter TA; Ge L; Guy TS; Guccione J; Tseng EE J Heart Valve Dis; 2009 Jul; 18(4):367-73. PubMed ID: 19852139 [TBL] [Abstract][Full Text] [Related]
44. Decalcification of the aortic valve does not prevent early recalcification. Dahm M; Dohmen G; Groh E; Krummenauer F; Hafner G; Mayer E; Hake U; Oelert H J Heart Valve Dis; 2000 Jan; 9(1):21-6. PubMed ID: 10678372 [TBL] [Abstract][Full Text] [Related]
45. The influence of sizing on the dynamic function of the free-hand implanted porcine aortic homograft: an in vitro study. Thubrikar MJ; Konstantinov IE; Selim GA; Gong GG; Fowler B; Robicsek F J Heart Valve Dis; 1999 May; 8(3):242-53. PubMed ID: 10399656 [TBL] [Abstract][Full Text] [Related]
47. Vena cava as autologous tissue for pulmonary valve substitute. Scharfschwerdt M; Sievers HH; von Heinz M; Schmidtke C Interact Cardiovasc Thorac Surg; 2008 Dec; 7(6):973-6. PubMed ID: 18718954 [TBL] [Abstract][Full Text] [Related]
48. Biomechanics of the aortic valve in the continuous flow VAD-assisted heart. May-Newman K; Enriquez-Almaguer L; Posuwattanakul P; Dembitsky W ASAIO J; 2010; 56(4):301-8. PubMed ID: 20559132 [TBL] [Abstract][Full Text] [Related]
49. Ventriculo-aortic junction in human root. A geometric approach. Grousson N; Lim KH; Lim HS; Ooi ET; Salgues SL; Yeo JH; Goetz WA J Biomech; 2007; 40(10):2167-73. PubMed ID: 17166505 [TBL] [Abstract][Full Text] [Related]
50. In-vitro hemodynamics of stented bioprosthetic heart valves in the tilted implantation position. Babin-Ebell J; Sievers HH; Misfeld M; Runge M; Vogt PR; Scharfschwerdt M J Heart Valve Dis; 2008 Sep; 17(5):566-70. PubMed ID: 18980091 [TBL] [Abstract][Full Text] [Related]
51. Pressure-volume relationship in isolated working heart with crystalloid perfusate in swine and imaging the valve motion. Araki Y; Usui A; Kawaguchi O; Saito S; Song MH; Akita T; Ueda Y Eur J Cardiothorac Surg; 2005 Sep; 28(3):435-42. PubMed ID: 16054376 [TBL] [Abstract][Full Text] [Related]
52. Decellularization reduces calcification while improving both durability and 1-year functional results of pulmonary homograft valves in juvenile sheep. Hopkins RA; Jones AL; Wolfinbarger L; Moore MA; Bert AA; Lofland GK J Thorac Cardiovasc Surg; 2009 Apr; 137(4):907-13, 913e1-4. PubMed ID: 19327516 [TBL] [Abstract][Full Text] [Related]
53. [Experimental study on mechanical properties of decellularized porcine aortic valve and effects of precoating methods of biological scaffold on histocompatibility]. Dong NG; Ye XF; Sun ZQ; Shi JW; Qiu YM; Chen JJ Zhonghua Wai Ke Za Zhi; 2007 Aug; 45(16):1128-31. PubMed ID: 18005619 [TBL] [Abstract][Full Text] [Related]
54. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model. Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477 [TBL] [Abstract][Full Text] [Related]