These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

272 related articles for article (PubMed ID: 18594300)

  • 1. Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating.
    Sagi HC; Papp S
    J Orthop Trauma; 2008 Jul; 22(6):373-8. PubMed ID: 18594300
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Early failure of symphysis pubis plating.
    Eastman JG; Krieg JC; Routt ML
    Injury; 2016 Aug; 47(8):1707-12. PubMed ID: 27282685
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Locked versus standard unlocked plating of the pubic symphysis: a cadaver biomechanical study.
    Grimshaw CS; Bledsoe JG; Moed BR
    J Orthop Trauma; 2012 Jul; 26(7):402-6. PubMed ID: 22183199
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Failure of locked design-specific plate fixation of the pubic symphysis: a report of six cases.
    Moed BR; Grimshaw CS; Segina DN
    J Orthop Trauma; 2012 Jul; 26(7):e71-5. PubMed ID: 22183198
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Internal fixation of symphyseal disruption resulting from childbirth.
    Najibi S; Tannast M; Klenck RE; Matta JM
    J Orthop Trauma; 2010 Dec; 24(12):732-9. PubMed ID: 21063219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Effect of Implant Failure After Symphyseal Plating on Functional Outcome and General Health.
    Frietman B; Verbeek J; Biert J; Frölke JP
    J Orthop Trauma; 2016 Jun; 30(6):336-9. PubMed ID: 26655520
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Locked versus standard unlocked plating of the symphysis pubis in a Type-C pelvic injury: a cadaver biomechanical study.
    Moed BR; O'Boynick CP; Bledsoe JG
    Injury; 2014 Apr; 45(4):748-51. PubMed ID: 24326027
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiographic changes of implant failure after plating for pubic symphysis diastasis: an underappreciated reality?
    Collinge C; Archdeacon MT; Dulaney-Cripe E; Moed BR
    Clin Orthop Relat Res; 2012 Aug; 470(8):2148-53. PubMed ID: 22552765
    [TBL] [Abstract][Full Text] [Related]  

  • 9. INFIX versus plating for pelvic fractures with disruption of the symphysis pubis.
    Vaidya R; Martin AJ; Roth M; Nasr K; Gheraibeh P; Tonnos F
    Int Orthop; 2017 Aug; 41(8):1671-1678. PubMed ID: 28078361
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Posterior Fixation of APC-2 Pelvic Ring Injuries Decreases Rates of Anterior Plate Failure and Malunion.
    Avilucea FR; Whiting PS; Mir H
    J Bone Joint Surg Am; 2016 Jun; 98(11):944-51. PubMed ID: 27252439
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The radiographic outcome after plating for pubic symphysis diastasis: does it matter clinically?
    Tseng KY; Lin KC; Yang SW
    Arch Orthop Trauma Surg; 2023 Apr; 143(4):1965-1972. PubMed ID: 35278092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Osteosynthesis of Anterior Pelvic Segment: New Symphyseal Plate - First Clinical Experience].
    Šrám J; Taller S; Harcuba R; Křivohlávek M; Lukáš R; Džupa V
    Acta Chir Orthop Traumatol Cech; 2018; 85(1):9-16. PubMed ID: 30257763
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is fixation failure after plate fixation of the symphysis pubis clinically important?
    Morris SA; Loveridge J; Smart DK; Ward AJ; Chesser TJ
    Clin Orthop Relat Res; 2012 Aug; 470(8):2154-60. PubMed ID: 22707071
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical study of 4-hole pubic symphyseal plating: locked versus unlocked constructs.
    Prasarn ML; Zych G; Gaski G; Baria D; Kaimrajh D; Milne T; Latta LL
    Orthopedics; 2012 Jul; 35(7):e1028-32. PubMed ID: 22784895
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does Posterior Fixation of Partially Unstable Open-Book Pelvic Ring Injuries Decrease Symphyseal Plate Failure? A Biomechanical Study.
    Metz RM; Bledsoe JG; Moed BR
    J Orthop Trauma; 2018 Feb; 32 Suppl 1():S18-S24. PubMed ID: 29373447
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Substitutional semi-rigid osteosynthesis technique for treatment of unstable pubic symphysis injuries: a biomechanical study.
    Berk T; Zderic I; Varga P; Schwarzenberg P; Berk K; Grüneweller N; Pastor T; Halvachizadeh S; Richards G; Gueorguiev B; Pape HC
    Eur J Trauma Emerg Surg; 2023 Dec; 49(6):2569-2578. PubMed ID: 37555991
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does Removal of the Symphyseal Cartilage in Symphyseal Dislocations Have Any Effect on Final Alignment and Implant Failure?
    Lybrand K; Kurylo J; Gross J; Templeman D; Tornetta P
    J Orthop Trauma; 2015 Oct; 29(10):470-4. PubMed ID: 26165255
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pelvic ring disruptions with symphysis pubis diastasis. Indications, technique, and limitations of anterior internal fixation.
    Lange RH; Hansen ST
    Clin Orthop Relat Res; 1985 Dec; (201):130-7. PubMed ID: 4064397
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fixation of pubic symphyseal disruptions: one or two plates?
    Bagchi K; Uhl RL
    Orthopedics; 2009 Jun; 32(6):427. PubMed ID: 19634818
    [No Abstract]   [Full Text] [Related]  

  • 20. No clinical advantage of locking over nonlocking plate fixation of symphyseal disruptions.
    Uliana CS; Nakahashi ER; Silva LHP; Freitas A; Giordano V
    Rev Col Bras Cir; 2021; 48():e20213122. PubMed ID: 34932737
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.