153 related articles for article (PubMed ID: 18599241)
1. Advantages of using multiple-echo image combination and asymmetric triangular phase masking in magnetic resonance venography at 3 T.
Brainovich V; Sabatini U; Hagberg GE
Magn Reson Imaging; 2009 Jan; 27(1):23-37. PubMed ID: 18599241
[TBL] [Abstract][Full Text] [Related]
2. Multi-echo acquisition of MR angiography and venography of the brain at 3 Tesla.
Du YP; Jin Z; Hu Y; Tanabe J
J Magn Reson Imaging; 2009 Aug; 30(2):449-54. PubMed ID: 19629975
[TBL] [Abstract][Full Text] [Related]
3. A new automatic phase mask filter for high-resolution brain venography at 3 T: theoretical background and experimental validation.
Casciaro S; Bianco R; Franchini R; Casciaro E; Conversano F
Magn Reson Imaging; 2010 May; 28(4):511-9. PubMed ID: 20117897
[TBL] [Abstract][Full Text] [Related]
4. Noncontrast-enhanced three-dimensional magnetic resonance aortography of the thorax at 3.0 T using respiratory-compensated T1-weighted k-space segmented gradient-echo imaging with radial data sampling: preliminary study.
Amano Y; Takahama K; Kumita S
Invest Radiol; 2009 Sep; 44(9):548-52. PubMed ID: 19652612
[TBL] [Abstract][Full Text] [Related]
5. Automated unwrapping of MR phase images applied to BOLD MR-venography at 3 Tesla.
Rauscher A; Barth M; Reichenbach JR; Stollberger R; Moser E
J Magn Reson Imaging; 2003 Aug; 18(2):175-80. PubMed ID: 12884329
[TBL] [Abstract][Full Text] [Related]
6. ToF-SWI: simultaneous time of flight and fully flow compensated susceptibility weighted imaging.
Deistung A; Dittrich E; Sedlacik J; Rauscher A; Reichenbach JR
J Magn Reson Imaging; 2009 Jun; 29(6):1478-84. PubMed ID: 19472425
[TBL] [Abstract][Full Text] [Related]
7. Artifact reduction of susceptibility-weighted imaging using a short-echo phase mask.
Ishimori Y; Monma M; Kohno Y
Acta Radiol; 2009 Nov; 50(9):1027-34. PubMed ID: 19863413
[TBL] [Abstract][Full Text] [Related]
8. MR venography of the brain with enhanced vessel contrast using image-domain high-pass filtering of the susceptibility phase shift.
Jin Z; Xia L; Lou M; Zhang M; Du YP
J Magn Reson Imaging; 2011 Nov; 34(5):1218-25. PubMed ID: 22006554
[TBL] [Abstract][Full Text] [Related]
9. The effect of physiological noise in phase functional magnetic resonance imaging: from blood oxygen level-dependent effects to direct detection of neuronal currents.
Hagberg GE; Bianciardi M; Brainovich V; CassarĂ AM; Maraviglia B
Magn Reson Imaging; 2008 Sep; 26(7):1026-40. PubMed ID: 18479875
[TBL] [Abstract][Full Text] [Related]
10. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.
Attenberger UI; Ingrisch M; Dietrich O; Herrmann K; Nikolaou K; Reiser MF; Schönberg SO; Fink C
Invest Radiol; 2009 Sep; 44(9):525-31. PubMed ID: 19652608
[TBL] [Abstract][Full Text] [Related]
11. Improved elimination of phase effects from background field inhomogeneities for susceptibility weighted imaging at high magnetic field strengths.
Rauscher A; Barth M; Herrmann KH; Witoszynskyj S; Deistung A; Reichenbach JR
Magn Reson Imaging; 2008 Oct; 26(8):1145-51. PubMed ID: 18524525
[TBL] [Abstract][Full Text] [Related]
12. Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions.
Brewer KD; Rioux JA; D'Arcy RC; Bowen CV; Beyea SD
NMR Biomed; 2009 Jul; 22(6):654-62. PubMed ID: 19382109
[TBL] [Abstract][Full Text] [Related]
13. Three-dimensional magnetic resonance observation of cartilage repair tissue (MOCART) score assessed with an isotropic three-dimensional true fast imaging with steady-state precession sequence at 3.0 Tesla.
Welsch GH; Zak L; Mamisch TC; Resinger C; Marlovits S; Trattnig S
Invest Radiol; 2009 Sep; 44(9):603-12. PubMed ID: 19692843
[TBL] [Abstract][Full Text] [Related]
14. Improvement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising.
Jang U; Nam Y; Kim DH; Hwang D
Neuroimage; 2013 Apr; 70():308-16. PubMed ID: 23296184
[TBL] [Abstract][Full Text] [Related]
15. The role of voxel aspect ratio in determining apparent vascular phase behavior in susceptibility weighted imaging.
Xu Y; Haacke EM
Magn Reson Imaging; 2006 Feb; 24(2):155-60. PubMed ID: 16455403
[TBL] [Abstract][Full Text] [Related]
16. Improved spatial localization based on flow-moment-nulled and intra-voxel incoherent motion-weighted fMRI.
Song AW; Li T
NMR Biomed; 2003 May; 16(3):137-43. PubMed ID: 12884357
[TBL] [Abstract][Full Text] [Related]
17. Three-dimensional fast spoiled gradient-echo dual echo (3D-FSPGR-DE) with water reconstruction: preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging.
Low RN; Panchal N; Vu AT; Knowles A; Estkowski L; Slavens Z; Ma J
J Magn Reson Imaging; 2008 Oct; 28(4):946-56. PubMed ID: 18821620
[TBL] [Abstract][Full Text] [Related]
18. Improved cardiac sodium MR imaging by density-weighted phase-encoding.
Greiser A; Haase A; von Kienlin M
J Magn Reson Imaging; 2005 Jan; 21(1):78-81. PubMed ID: 15611944
[TBL] [Abstract][Full Text] [Related]
19. Limits of 8-Tesla magnetic resonance imaging spatial resolution of the deoxygenated cerebral microvasculature.
Dashner RA; Kangarlu A; Clark DL; RayChaudhury A; Chakeres DW
J Magn Reson Imaging; 2004 Mar; 19(3):303-7. PubMed ID: 14994298
[TBL] [Abstract][Full Text] [Related]
20. Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: potential medical imaging applications in the post-Nyquist era.
Mistretta CA
J Magn Reson Imaging; 2009 Mar; 29(3):501-16. PubMed ID: 19243031
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]