BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 18600416)

  • 1. Development of a tweezers-type coincidence imaging detector.
    Yamamoto S; Sakamoto Y; Matsumoto K; Senda M
    Ann Nucl Med; 2008 Jun; 22(5):387-93. PubMed ID: 18600416
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Depth of interaction decoding of a continuous crystal detector module.
    Ling T; Lewellen TK; Miyaoka RS
    Phys Med Biol; 2007 Apr; 52(8):2213-28. PubMed ID: 17404465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes.
    Yang Y; Dokhale PA; Silverman RW; Shah KS; McClish MA; Farrell R; Entine G; Cherry SR
    Phys Med Biol; 2006 May; 51(9):2131-42. PubMed ID: 16625031
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design of a very high-resolution small animal PET scanner using a silicon scatter detector insert.
    Park SJ; Rogers WL; Clinthorne NH
    Phys Med Biol; 2007 Aug; 52(15):4653-77. PubMed ID: 17634656
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A GSO tweezers-type coincidence detector for tumor detection.
    Yamamoto S; Higashi T; Senda M
    Radiol Phys Technol; 2013 Jul; 6(2):293-8. PubMed ID: 23283753
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.
    Matsumoto K; Kitamura K; Mizuta T; Tanaka K; Yamamoto S; Sakamoto S; Nakamoto Y; Amano M; Murase K; Senda M
    J Nucl Med; 2006 Jan; 47(1):83-90. PubMed ID: 16391191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The PETRRA positron camera: design, characterization and results of a physical evaluation.
    Divoli A; Flower MA; Erlandsson K; Reader AJ; Evans N; Meriaux S; Ott RJ; Stephenson R; Bateman JE; Duxbury DM; Spill EJ
    Phys Med Biol; 2005 Sep; 50(17):3971-88. PubMed ID: 16177524
    [TBL] [Abstract][Full Text] [Related]  

  • 8. LaBr(3):Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time.
    Schaart DR; Seifert S; Vinke R; van Dam HT; Dendooven P; Löhner H; Beekman FJ
    Phys Med Biol; 2010 Apr; 55(7):N179-89. PubMed ID: 20299734
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A four-layer attenuation compensated PET detector based on APD arrays without discrete crystal elements.
    McCallum S; Clowes P; Welch A
    Phys Med Biol; 2005 Sep; 50(17):4187-207. PubMed ID: 16177539
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A compact and high sensitivity positron detector using dual-layer thin GSO scintillators for a small animal PET blood sampling system.
    Yamamoto S; Imaizumi M; Shimosegawa E; Kanai Y; Sakamoto Y; Minato K; Shimizu K; Senda M; Hatazawa J
    Phys Med Biol; 2010 Jul; 55(13):3813-26. PubMed ID: 20551500
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a positron-imaging detector with background rejection capability.
    Yamamoto S; Higashi T; Matsumoto K; Senda M
    Ann Nucl Med; 2006 Dec; 20(10):655-62. PubMed ID: 17385303
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel phoswich imaging detector for simultaneous beta and coincidence-gamma imaging of plant leaves.
    Wu H; Tai YC
    Phys Med Biol; 2011 Sep; 56(17):5583-98. PubMed ID: 21828901
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A proposal of an open PET geometry.
    Yamaya T; Inaniwa T; Minohara S; Yoshida E; Inadama N; Nishikido F; Shibuya K; Lam CF; Murayama H
    Phys Med Biol; 2008 Feb; 53(3):757-73. PubMed ID: 18199913
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A position sensitive gamma-ray scintillator detector with enhanced spatial resolution, linearity, and field of view.
    Domingo-Pardo C; Goel N; Engert T; Gerl J; Isaka M; Kojouharov I; Schaffner H
    IEEE Trans Med Imaging; 2009 Dec; 28(12):2007-14. PubMed ID: 19628451
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of Geiger-mode APDs for PET block detector designs.
    Kolb A; Lorenz E; Judenhofer MS; Renker D; Lankes K; Pichler BJ
    Phys Med Biol; 2010 Apr; 55(7):1815-32. PubMed ID: 20208095
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a parallel detection and processing system using a multidetector array for wave field restoration in scanning transmission electron microscopy.
    Taya M; Matsutani T; Ikuta T; Saito H; Ogai K; Harada Y; Tanaka T; Takai Y
    Rev Sci Instrum; 2007 Aug; 78(8):083705. PubMed ID: 17764327
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.
    Maas MC; Schaart DR; van der Laan DJ; Bruyndonckx P; Lemaître C; Beekman FJ; van Eijk CW
    Phys Med Biol; 2009 Apr; 54(7):1893-908. PubMed ID: 19265203
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Highly absorbing gadolinium test device to characterize the performance of neutron imaging detector systems.
    Grünzweig C; Frei G; Lehmann E; Kühne G; David C
    Rev Sci Instrum; 2007 May; 78(5):053708. PubMed ID: 17552826
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance evaluation of a high-sensitivity large-aperture small-animal PET scanner: ClairvivoPET.
    Mizuta T; Kitamura K; Iwata H; Yamagishi Y; Ohtani A; Tanaka K; Inoue Y
    Ann Nucl Med; 2008 Jun; 22(5):447-55. PubMed ID: 18600425
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance evaluation of a very high resolution small animal PET imager using silicon scatter detectors.
    Park SJ; Rogers WL; Huh S; Kagan H; Honscheid K; Burdette D; Chesi E; Lacasta C; Llosa G; Mikuz M; Studen A; Weilhammer P; Clinthorne NH
    Phys Med Biol; 2007 May; 52(10):2807-26. PubMed ID: 17473353
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.