These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 18601418)

  • 1. A new photolysis laser-induced fluorescence instrument for the detection of H2O and HDO in the lower stratosphere.
    St Clair JM; Hanisco TF; Weinstock EM; Moyer EJ; Sayres DS; Keutsch FN; Kroll JH; Demusz JN; Allen NT; Smith JB; Spackman JR; Anderson JG
    Rev Sci Instrum; 2008 Jun; 79(6):064101. PubMed ID: 18601418
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new cavity based absorption instrument for detection of water isotopologues in the upper troposphere and lower stratosphere.
    Sayres DS; Moyer EJ; Hanisco TF; St Clair JM; Keutsch FN; O'Brien A; Allen NT; Lapson L; Demusz JN; Rivero M; Martin T; Greenberg M; Tuozzolo C; Engel GS; Kroll JH; Paul JB; Anderson JG
    Rev Sci Instrum; 2009 Apr; 80(4):044102. PubMed ID: 19405676
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new direct absorption tunable diode laser spectrometer for high precision measurement of water vapor in the upper troposphere and lower stratosphere.
    Sargent MR; Sayres DS; Smith JB; Witinski M; Allen NT; Demusz JN; Rivero M; Tuozzolo C; Anderson JG
    Rev Sci Instrum; 2013 Jul; 84(7):074102. PubMed ID: 23902086
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and airborne operation of a compact water isotope ratio infrared spectrometer.
    Iannone RQ; Kassi S; Jost HJ; Chenevier M; Romanini D; Meijer HA; Dhaniyala S; Snels M; Kerstel ER
    Isotopes Environ Health Stud; 2009 Dec; 45(4):303-20. PubMed ID: 19670069
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Chicago Water Isotope Spectrometer (ChiWIS-lab): A tunable diode laser spectrometer for chamber-based measurements of water vapor isotopic evolution during cirrus formation.
    Sarkozy LC; Clouser BW; Lamb KD; Stutz EJ; Saathoff H; Möhler O; Ebert V; Moyer EJ
    Rev Sci Instrum; 2020 Apr; 91(4):045120. PubMed ID: 32357726
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of tropospheric RO2 and HO2 radicals by a laser-induced fluorescence instrument.
    Fuchs H; Holland F; Hofzumahaus A
    Rev Sci Instrum; 2008 Aug; 79(8):084104. PubMed ID: 19044365
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Short circuit of water vapor and polluted air to the global stratosphere by convective transport over the Tibetan Plateau.
    Fu R; Hu Y; Wright JS; Jiang JH; Dickinson RE; Chen M; Filipiak M; Read WG; Waters JW; Wu DL
    Proc Natl Acad Sci U S A; 2006 Apr; 103(15):5664-9. PubMed ID: 16585523
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-precision laser spectroscopy D/H and 18O/16O measurements of microliter natural water samples.
    Lis G; Wassenaar LI; Hendry MJ
    Anal Chem; 2008 Jan; 80(1):287-93. PubMed ID: 18031060
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Absorption spectra of deuterated water at DF laser wavelengths.
    Bruce CW; Jelinek AV
    Appl Opt; 1982 Nov; 21(22):4101-5. PubMed ID: 20401016
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A lightweight near-infrared spectrometer for the detection of trace atmospheric species.
    Gardiner T; Mead MI; Garcelon S; Robinson R; Swann N; Hansford GM; Woods PT; Jones RL
    Rev Sci Instrum; 2010 Aug; 81(8):083102. PubMed ID: 20815598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wavelength modulated cavity enhanced absorption spectroscopy of water in the 1.37 microm region.
    Vasudev R
    Appl Spectrosc; 2006 Aug; 60(8):926-30. PubMed ID: 16925930
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantifying stratospheric ozone in the upper troposphere with in situ measurements of HCl.
    Marcy TP; Fahey DW; Gao RS; Popp PJ; Richard EC; Thompson TL; Rosenlof KH; Ray EA; Salawitch RJ; Atherton CS; Bergmann DJ; Ridley BA; Weinheimer AJ; Loewenstein M; Weinstock EM; Mahoney MJ
    Science; 2004 Apr; 304(5668):261-5. PubMed ID: 15073371
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic processes governing lower-tropospheric HDO/H2O ratios as observed from space and ground.
    Frankenberg C; Yoshimura K; Warneke T; Aben I; Butz A; Deutscher N; Griffith D; Hase F; Notholt J; Schneider M; Schrijver H; Röckmann T
    Science; 2009 Sep; 325(5946):1374-7. PubMed ID: 19745148
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of UT/LS hygrometer accuracy by intercomparison during the NASA MACPEX mission.
    Rollins AW; Thornberry TD; Gao RS; Smith JB; Sayres DS; Sargent MR; Schiller C; Krämer M; Spelten N; Hurst DF; Jordan AF; Hall EG; Vömel H; Diskin GS; Podolske JR; Christensen LE; Rosenlof KH; Jensen EJ; Fahey DW
    J Geophys Res Atmos; 2014 Feb; 119(4):1915-1935. PubMed ID: 28845379
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of water vapor in the stratosphere by photodissociation with Ly alpha (1216 A) light.
    Kley D; Stone EJ
    Rev Sci Instrum; 1978 Jun; 49(6):691. PubMed ID: 18699175
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Note: a laser-flash photolysis and laser-induced fluorescence detection technique for measuring total HO2 reactivity in ambient air.
    Miyazaki K; Nakashima Y; Schoemaecker C; Fittschen C; Kajii Y
    Rev Sci Instrum; 2013 Jul; 84(7):076106. PubMed ID: 23902123
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the calibration of continuous, high-precision delta18O and delta2H measurements using an off-axis integrated cavity output spectrometer.
    Wang L; Caylor KK; Dragoni D
    Rapid Commun Mass Spectrom; 2009 Feb; 23(4):530-6. PubMed ID: 19142848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Water's role in reshaping a macrocycle's binding pocket: infrared and ultraviolet spectroscopy of benzo-15-crown-5-(H(2)O)(n) and 4'-aminobenzo-15-crown-5-(H(2)O)(n), n = 1, 2.
    Shubert VA; Müller CW; Zwier TS
    J Phys Chem A; 2009 Jul; 113(28):8067-79. PubMed ID: 19552395
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Kalman filtering real-time measurements of H2O isotopologue ratios by laser absorption spectroscopy at 2.73 microm.
    Wu T; Chen W; Kerstel E; Fertein E; Gao X; Koeth J; Rössner K; Brückner D
    Opt Lett; 2010 Mar; 35(5):634-6. PubMed ID: 20195302
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In situ measurements of H2O from a stratospheric balloon by diode laser direct-differential absorption spectroscopy at 1.39 microm.
    Durry G; Megie G
    Appl Opt; 2000 Oct; 39(30):5601-8. PubMed ID: 18354557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.