BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

329 related articles for article (PubMed ID: 18602976)

  • 1. The effect of lubrication on density distributions of roller compacted ribbons.
    Miguélez-Morán AM; Wu CY; Seville JP
    Int J Pharm; 2008 Oct; 362(1-2):52-9. PubMed ID: 18602976
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Roller compaction of moist pharmaceutical powders.
    Wu CY; Hung WL; Miguélez-Morán AM; Gururajan B; Seville JP
    Int J Pharm; 2010 May; 391(1-2):90-7. PubMed ID: 20176096
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterisation of density distributions in roller-compacted ribbons using micro-indentation and X-ray micro-computed tomography.
    Miguélez-Morán AM; Wu CY; Dong H; Seville JP
    Eur J Pharm Biopharm; 2009 May; 72(1):173-82. PubMed ID: 19130881
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Roller compaction process development and scale up using Johanson model calibrated with instrumented roll data.
    Nesarikar VV; Patel C; Early W; Vatsaraj N; Sprockel O; Jerzweski R
    Int J Pharm; 2012 Oct; 436(1-2):486-507. PubMed ID: 22721851
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An investigation into the impact of magnesium stearate on powder feeding during roller compaction.
    Dawes J; Gamble JF; Greenwood R; Robbins P; Tobyn M
    Drug Dev Ind Pharm; 2012 Jan; 38(1):111-22. PubMed ID: 21810064
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Instrumented roll technology for the design space development of roller compaction process.
    Nesarikar VV; Vatsaraj N; Patel C; Early W; Pandey P; Sprockel O; Gao Z; Jerzewski R; Miller R; Levin M
    Int J Pharm; 2012 Apr; 426(1-2):116-131. PubMed ID: 22286023
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A quantitative correlation of the effect of density distributions in roller-compacted ribbons on the mechanical properties of tablets using ultrasonics and X-ray tomography.
    Akseli I; Iyer S; Lee HP; Cuitiño AM
    AAPS PharmSciTech; 2011 Sep; 12(3):834-53. PubMed ID: 21710336
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Roller compaction: Ribbon splitting and sticking.
    Mahmah O; Adams MJ; Omar CS; Gururajan B; Salman AD
    Int J Pharm; 2019 Mar; 559():156-172. PubMed ID: 30682449
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of feeding guiders to improve the powder distribution in the two scales of roller compactors.
    Yu M; Weidemann M; Omar CS; Schmidt A; Litster JD; Salman AD
    Int J Pharm; 2020 Jan; 573():118815. PubMed ID: 31751637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluating and modifying Johanson's rolling model to improve its predictability.
    Bi M; Alvarez-Nunez F; Alvarez F
    J Pharm Sci; 2014 Jul; 103(7):2062-2071. PubMed ID: 24840775
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Commercial scale validation of a process scale-up model for lubricant blending of pharmaceutical powders.
    Kushner J; Schlack H
    Int J Pharm; 2014 Nov; 475(1-2):147-55. PubMed ID: 25152166
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improving feeding powder distribution to the compaction zone in the roller compaction.
    Yu M; Omar C; Schmidt A; Litster JD; Salman AD
    Eur J Pharm Biopharm; 2018 Jul; 128():57-68. PubMed ID: 29678732
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparative study of roll compaction of free-flowing and cohesive pharmaceutical powders.
    Yu S; Gururajan B; Reynolds G; Roberts R; Adams MJ; Wu CY
    Int J Pharm; 2012 May; 428(1-2):39-47. PubMed ID: 22402475
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanistic study of the effect of roller compaction and lubricant on tablet mechanical strength.
    He X; Secreast PJ; Amidon GE
    J Pharm Sci; 2007 May; 96(5):1342-55. PubMed ID: 17455360
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Parameter estimation for roller compaction process using an instrumented vector TF mini roller compactor.
    Reddy JP; Phanse R; Nesarikar V
    Pharm Dev Technol; 2019 Dec; 24(10):1250-1257. PubMed ID: 31437082
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of external lubrication during the roller compaction of adhesive pharmaceutical formulations.
    Dawes J; Allenspach C; Gamble JF; Greenwood R; Robbins P; Tobyn M
    Pharm Dev Technol; 2013 Feb; 18(1):246-56. PubMed ID: 22813432
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Roller compaction: Infrared thermography as a PAT for monitoring powder flow from feeding to compaction zone.
    Yu M; Omar C; Weidemann M; Schmidt A; Litster JD; Salman AD
    Int J Pharm; 2020 Mar; 578():119114. PubMed ID: 32035257
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evolutions of temperature and density during roll compaction of a pharmaceutical excipient.
    Krok A; Wu CY
    Int J Pharm; 2019 Dec; 572():118822. PubMed ID: 31678375
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of the variation in the ambient moisture on the compaction behavior of powder undergoing roller-compaction and on the characteristics of tablets produced from the post-milled granules.
    Gupta A; Peck GE; Miller RW; Morris KR
    J Pharm Sci; 2005 Oct; 94(10):2314-26. PubMed ID: 16136545
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The influence of API concentration on the roller compaction process: modeling and prediction of the post compacted ribbon, granule and tablet properties using multivariate data analysis.
    Boersen N; Carvajal MT; Morris KR; Peck GE; Pinal R
    Drug Dev Ind Pharm; 2015; 41(9):1470-8. PubMed ID: 25212638
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.