These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 18604612)

  • 1. Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses.
    Akutsu T; Saito J; Imai R; Suzuki T; Cao XD
    J Artif Organs; 2008; 11(2):75-90. PubMed ID: 18604612
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta.
    Akutsu T; Matsumoto A
    J Artif Organs; 2010 Dec; 13(4):207-17. PubMed ID: 20924771
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.
    Akutsu T; Saito J
    J Artif Organs; 2006; 9(3):165-78. PubMed ID: 16998702
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses.
    Akutsu T; Fukuda T
    J Artif Organs; 2005; 8(3):171-83. PubMed ID: 16235034
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation technique for bileaflet mechanical valves.
    Shipkowitz T; Ambrus J; Kurk J; Wickramasinghe K
    J Heart Valve Dis; 2002 Mar; 11(2):275-82. PubMed ID: 12000172
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro hydrodynamic characteristics among three bileaflet valves in the mitral position.
    Feng Z; Umezu M; Fujimoto T; Tsukahara T; Nurishi M; Kawaguchi D
    Artif Organs; 2000 May; 24(5):346-54. PubMed ID: 10848675
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of the flow field of mechanical bileaflet mitral prostheses on valve closing.
    Akutsu T; Imai R; Deguchi Y
    J Artif Organs; 2005; 8(3):161-70. PubMed ID: 16235033
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis.
    Akutsu T; Masuda T
    J Artif Organs; 2003; 6(2):112-23. PubMed ID: 14598112
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry.
    Manning KB; Kini V; Fontaine AA; Deutsch S; Tarbell JM
    Artif Organs; 2003 Sep; 27(9):840-6. PubMed ID: 12940907
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fluid dynamics of the CarboMedics kinetic bileaflet prosthetic heart valve.
    Baldwin JT; Campbell A; Luck C; Ogilvie W; Sauter J
    Eur J Cardiothorac Surg; 1997 Feb; 11(2):287-92. PubMed ID: 9080157
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow.
    Subramanian A; Mu H; Kadambi JR; Wernet MP; Brendzel AM; Harasaki H
    J Heart Valve Dis; 2000 Sep; 9(5):721-31. PubMed ID: 11041190
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A turbulence in vitro assessment of On-X and St Jude Medical prostheses.
    Hatoum H; Maureira P; Dasi LP
    J Thorac Cardiovasc Surg; 2020 Jan; 159(1):88-97. PubMed ID: 30905419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Numerical analysis of the hemodynamic performance of bileaflet mechanical heart valves at different implantation angles.
    Kuan YH; Nguyen VT; Kabinejadian F; Su B; Kim S; Yoganathan AP; Leo HL
    J Heart Valve Dis; 2014 Sep; 23(5):642-50. PubMed ID: 25799715
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: comparison of experimental and numerical results.
    King MJ; Corden J; David T; Fisher J
    J Biomech; 1996 May; 29(5):609-18. PubMed ID: 8707787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow characterization of the ADVANTAGE and St. Jude Medical bileaflet mechanical heart valves.
    Shu MC; O'Rourke KK; Coppin CM; Lemmon JD
    J Heart Valve Dis; 2004 Sep; 13(5):814-22. PubMed ID: 15473485
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Correlation between ventricular flow field and valve closing sound of mechanical mitral prostheses.
    Akutsu T; Imai R; Saito J; Suzuki T
    J Artif Organs; 2008; 11(2):67-74. PubMed ID: 18604611
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
    Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D
    J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The closing behavior of mechanical aortic heart valve prostheses.
    Lu PC; Liu JS; Huang RH; Lo CW; Lai HC; Hwang NH
    ASAIO J; 2004; 50(4):294-300. PubMed ID: 15307536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 3D velocity field characterization of prosthetic heart valve with two different valve testers by means of stereo-PIV.
    D'Avenio G; Grigioni M; Daniele C; Morbiducci U; Hamilton K
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():3327-30. PubMed ID: 26737004
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.
    Shi Y; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):245-55. PubMed ID: 12701798
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.