177 related articles for article (PubMed ID: 18612267)
1. Transcutaneous carbon dioxide monitoring in spontaneously breathing, nonintubated patients in the early postoperative period.
Fanelli G; Baciarello M; Squicciarini G; Malagutti G; Zasa M; Casati A
Minerva Anestesiol; 2008; 74(7-8):375-80. PubMed ID: 18612267
[TBL] [Abstract][Full Text] [Related]
2. Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department.
McVicar J; Eager R
Emerg Med J; 2009 May; 26(5):344-6. PubMed ID: 19386868
[TBL] [Abstract][Full Text] [Related]
3. Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants < or = 28 weeks gestation.
Aliwalas LL; Noble L; Nesbitt K; Fallah S; Shah V; Shah PS
J Perinatol; 2005 Jan; 25(1):26-9. PubMed ID: 15496874
[TBL] [Abstract][Full Text] [Related]
4. Transcutaneous carbon dioxide monitoring accurately predicts arterial carbon dioxide partial pressure in patients undergoing prolonged laparoscopic surgery.
Xue Q; Wu X; Jin J; Yu B; Zheng M
Anesth Analg; 2010 Aug; 111(2):417-20. PubMed ID: 20584872
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of a combined transcutaneous carbon dioxide pressure and pulse oximetry sensor in adult sheep and dogs.
Vogt R; Rohling R; Kästner S
Am J Vet Res; 2007 Mar; 68(3):265-70. PubMed ID: 17331015
[TBL] [Abstract][Full Text] [Related]
6. Comparison of ear and chest probes in transcutaneous carbon dioxide pressure measurements during general anesthesia in adults.
Nishiyama T; Kohno Y; Koishi K
J Clin Monit Comput; 2011 Oct; 25(5):323-8. PubMed ID: 22009107
[TBL] [Abstract][Full Text] [Related]
7. End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers.
Casati A; Gallioli G; Passaretta R; Scandroglio M; Bignami E; Torri G
Minerva Anestesiol; 2001 Apr; 67(4):161-4. PubMed ID: 11376503
[TBL] [Abstract][Full Text] [Related]
8. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers].
Lehmann KA; Asoklis S; Grond S; Huttarsch H
Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
[TBL] [Abstract][Full Text] [Related]
10. Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: a prospective, clinical comparison with end-tidal monitoring.
Casati A; Squicciarini G; Malagutti G; Baciarello M; Putzu M; Fanelli A
J Clin Anesth; 2006 Sep; 18(6):436-40. PubMed ID: 16980160
[TBL] [Abstract][Full Text] [Related]
11. Accuracy of three transcutaneous carbon dioxide monitors in critically ill children.
Urbano J; Cruzado V; López-Herce J; del Castillo J; Bellón JM; Carrillo A
Pediatr Pulmonol; 2010 May; 45(5):481-6. PubMed ID: 20425856
[TBL] [Abstract][Full Text] [Related]
12. [Validation of the transcutaneous carbon dioxide tension measurements in critical paediatric patients].
Fernández de Miguel S; Gaboli M; González-Celador R; Gómez de Quero P; Murga Herrero V; Sánchez Granados JM; Payo Pérez R
An Pediatr (Barc); 2010 Mar; 72(3):165-71. PubMed ID: 20138816
[TBL] [Abstract][Full Text] [Related]
13. End-tidal carbon dioxide monitoring in very low birth weight infants: correlation and agreement with arterial carbon dioxide.
Trevisanuto D; Giuliotto S; Cavallin F; Doglioni N; Toniazzo S; Zanardo V
Pediatr Pulmonol; 2012 Apr; 47(4):367-72. PubMed ID: 22102598
[TBL] [Abstract][Full Text] [Related]
14. Agreement between values for arterial and end-tidal partial pressures of carbon dioxide in spontaneously breathing, critically ill dogs.
Kelmer E; Scanson LC; Reed A; Love LC
J Am Vet Med Assoc; 2009 Dec; 235(11):1314-8. PubMed ID: 19951100
[TBL] [Abstract][Full Text] [Related]
15. Good estimation of arterial carbon dioxide by end-tidal carbon dioxide monitoring in the neonatal intensive care unit.
Wu CH; Chou HC; Hsieh WS; Chen WK; Huang PY; Tsao PN
Pediatr Pulmonol; 2003 Apr; 35(4):292-5. PubMed ID: 12629627
[TBL] [Abstract][Full Text] [Related]
16. Assessing PaCO2 in acute respiratory disease: accuracy of a transcutaneous carbon dioxide device.
Perrin K; Wijesinghe M; Weatherall M; Beasley R
Intern Med J; 2011 Aug; 41(8):630-3. PubMed ID: 20214687
[TBL] [Abstract][Full Text] [Related]
17. Concordance between transcutaneous and arterial measurements of carbon dioxide in an ED.
Delerme S; Montout V; Goulet H; Arhan A; Le Saché F; Devilliers C; Riou B; Ray P
Am J Emerg Med; 2012 Nov; 30(9):1872-6. PubMed ID: 22795407
[TBL] [Abstract][Full Text] [Related]
18. Measurement of end-tidal carbon dioxide in spontaneously breathing children after cardiac surgery.
Rasera CC; Gewehr PM; Domingues AM; Junior FF
Am J Crit Care; 2011 Sep; 20(5):388-94. PubMed ID: 21885460
[TBL] [Abstract][Full Text] [Related]
19. Accuracy of transcutaneous carbon dioxide tension measurements during cardiopulmonary exercise testing.
Stege G; van den Elshout FJ; Heijdra YF; van de Ven MJ; Dekhuijzen PN; Vos PJ
Respiration; 2009; 78(2):147-53. PubMed ID: 19088464
[TBL] [Abstract][Full Text] [Related]
20. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea.
Kasuya Y; Akça O; Sessler DI; Ozaki M; Komatsu R
Anesthesiology; 2009 Sep; 111(3):609-15. PubMed ID: 19672177
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]