424 related articles for article (PubMed ID: 18620116)
21. Phantom-calibrated versus automatic coronary artery mass quantification with multidetector-row computed tomography: in vitro and in vivo study.
Serafin Z; Lasek W; Laskowska K
Acta Radiol; 2008 Nov; 49(9):1007-15. PubMed ID: 18720083
[TBL] [Abstract][Full Text] [Related]
22. Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT.
Horiguchi J; Yamamoto H; Hirai N; Akiyama Y; Fujioka C; Marukawa K; Fukuda H; Ito K
AJR Am J Roentgenol; 2006 Jul; 187(1):W1-6. PubMed ID: 16794121
[TBL] [Abstract][Full Text] [Related]
23. Estimation of radiation exposure of different dose saving techniques in 128-slice computed tomography coronary angiography.
Ketelsen D; Fenchel M; Buchgeister M; Thomas C; Boehringer N; Tsiflikas I; Kaempf M; Syha R; Claussen CD; Heuschmid M
Eur J Radiol; 2012 Feb; 81(2):e153-7. PubMed ID: 21333478
[TBL] [Abstract][Full Text] [Related]
24. Variability of repeated coronary artery calcium measurements by 1.25-mm- and 2.5-mm-thickness images on prospective electrocardiograph-triggered 64-slice CT.
Horiguchi J; Matsuura N; Yamamoto H; Hirai N; Kiguchi M; Fujioka C; Kitagawa T; Kohno N; Ito K
Eur Radiol; 2008 Feb; 18(2):209-16. PubMed ID: 17674003
[TBL] [Abstract][Full Text] [Related]
25. Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose.
DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; Zankl M; Angel E; McNitt-Gray MF
Phys Med Biol; 2007 May; 52(9):2583-97. PubMed ID: 17440254
[TBL] [Abstract][Full Text] [Related]
26. Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort--consequences for progression studies.
Hoffmann U; Siebert U; Bull-Stewart A; Achenbach S; Ferencik M; Moselewski F; Brady TJ; Massaro JM; O'Donnell CJ
Eur J Radiol; 2006 Mar; 57(3):396-402. PubMed ID: 16434160
[TBL] [Abstract][Full Text] [Related]
27. Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation ("ECG pulsing"): phantom measurements.
Poll LW; Cohnen M; Brachten S; Ewen K; Mödder U
Rofo; 2002 Dec; 174(12):1500-5. PubMed ID: 12471520
[TBL] [Abstract][Full Text] [Related]
28. Electron beam CT versus 16-slice spiral CT: how accurately can we measure coronary artery calcium volume?
Horiguchi J; Shen Y; Akiyama Y; Hirai N; Sasaki K; Ishifuro M; Ito K
Eur Radiol; 2006 Feb; 16(2):374-80. PubMed ID: 16175352
[TBL] [Abstract][Full Text] [Related]
29. Inter-scan variability of coronary artery calcium scoring assessed on 64-multidetector computed tomography vs. dual-source computed tomography: a head-to-head comparison.
Ghadri JR; Goetti R; Fiechter M; Pazhenkottil AP; Küest SM; Nkoulou RN; Windler C; Buechel RR; Herzog BA; Gaemperli O; Templin C; Kaufmann PA
Eur Heart J; 2011 Aug; 32(15):1865-74. PubMed ID: 21546450
[TBL] [Abstract][Full Text] [Related]
30. The influence of heart rate, slice thickness, and calcification density on calcium scores using 64-slice multidetector computed tomography: a systematic phantom study.
Groen JM; Greuter MJ; Schmidt B; Suess C; Vliegenthart R; Oudkerk M
Invest Radiol; 2007 Dec; 42(12):848-55. PubMed ID: 18007157
[TBL] [Abstract][Full Text] [Related]
31. Optimization of HU threshold for coronary artery calcium scans reconstructed at 0.5-mm slice thickness using iterative reconstruction.
Hou KY; Tsujioka K; Yang CC
J Appl Clin Med Phys; 2020 Feb; 21(2):111-120. PubMed ID: 31889419
[TBL] [Abstract][Full Text] [Related]
32. Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols.
Hurwitz LM; Yoshizumi TT; Goodman PC; Frush DP; Nguyen G; Toncheva G; Lowry C
J Comput Assist Tomogr; 2007; 31(4):544-9. PubMed ID: 17882029
[TBL] [Abstract][Full Text] [Related]
33. The impact of scan length on the exposure levels in 16- and 64-row multidetector computed tomography: a phantom study.
Irwan R; de Vries HB; Sijens PE
Acad Radiol; 2008 Sep; 15(9):1142-7. PubMed ID: 18692755
[TBL] [Abstract][Full Text] [Related]
34. Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan.
Maruyama T; Takada M; Hasuike T; Yoshikawa A; Namimatsu E; Yoshizumi T
J Am Coll Cardiol; 2008 Oct; 52(18):1450-5. PubMed ID: 19017511
[TBL] [Abstract][Full Text] [Related]
35. In vitro imaging of coronary artery stents: are there differences between 16- and 64-slice CT scanners?
Wolf F; Feuchtner GM; Homolka P; Langenberger H; Stadler A; Bader TR; Weber M; Lammer J; Loewe C
Eur J Radiol; 2008 Dec; 68(3):465-70. PubMed ID: 17913428
[TBL] [Abstract][Full Text] [Related]
36. Post-CABG coronary CT angiography: radiation dose and graft image quality in retrospective versus prospective ECG gating.
Chazen JL; Prince MR; Yip R; Min JK; Weinsaft JW; Henschke CI; Cham MD
Acad Radiol; 2010 Sep; 17(9):1122-7. PubMed ID: 20542451
[TBL] [Abstract][Full Text] [Related]
37. Optimization of low-contrast detectability in thin-collimated modern multidetector CT using an interactive sliding-thin-slab averaging algorithm.
von Falck C; Hartung A; Berndzen F; King B; Galanski M; Shin HO
Invest Radiol; 2008 Apr; 43(4):229-35. PubMed ID: 18340246
[TBL] [Abstract][Full Text] [Related]
38. Assessments of Coronary Artery Visibility and Radiation Dose in Infants with Congenital Heart Disease on Cardiac 128-slice CT and on Cardiac 64-slice CT.
Cui Y; Huang M; Zheng J; Li J; Liu H; Liang C
Pediatr Cardiol; 2016 Jan; 37(1):135-43. PubMed ID: 26271472
[TBL] [Abstract][Full Text] [Related]
39. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT.
Hunold P; Vogt FM; Schmermund A; Debatin JF; Kerkhoff G; Budde T; Erbel R; Ewen K; Barkhausen J
Radiology; 2003 Jan; 226(1):145-52. PubMed ID: 12511683
[TBL] [Abstract][Full Text] [Related]
40. In vitro measurement of CT density and estimation of stenosis related to coronary soft plaque at 100 kV and 120 kV on ECG-triggered scan.
Horiguchi J; Fujioka C; Kiguchi M; Yamamoto H; Shen Y; Kihara Y
Eur J Radiol; 2011 Feb; 77(2):294-8. PubMed ID: 19716249
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]