These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
296 related articles for article (PubMed ID: 1862898)
1. Tracheal tube resistance and airway and alveolar pressures during mechanical ventilation in the neonate. Tipping TR; Sykes MK Anaesthesia; 1991 Jul; 46(7):565-9. PubMed ID: 1862898 [TBL] [Abstract][Full Text] [Related]
2. Alveolar pressure and airway resistance during maximal and submaximal respiratory efforts. Aldrich TK; Shapiro SM; Sherman MS; Prezant DJ Am Rev Respir Dis; 1989 Oct; 140(4):899-906. PubMed ID: 2802377 [TBL] [Abstract][Full Text] [Related]
3. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses. Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615 [TBL] [Abstract][Full Text] [Related]
4. Tracheal gas insufflation augments CO2 clearance during mechanical ventilation. Ravenscraft SA; Burke WC; Nahum A; Adams AB; Nakos G; Marcy TW; Marini JJ Am Rev Respir Dis; 1993 Aug; 148(2):345-51. PubMed ID: 8342897 [TBL] [Abstract][Full Text] [Related]
5. Effect of I/E ratio on mean alveolar pressure during high-frequency oscillatory ventilation. Pillow JJ; Neil H; Wilkinson MH; Ramsden CA J Appl Physiol (1985); 1999 Jul; 87(1):407-14. PubMed ID: 10409602 [TBL] [Abstract][Full Text] [Related]
6. Tracheal gas insufflation-pressure control versus volume control ventilation. A lung model study. Imanaka H; Kacmarek RM; Ritz R; Hess D Am J Respir Crit Care Med; 1996 Mar; 153(3):1019-24. PubMed ID: 8630540 [TBL] [Abstract][Full Text] [Related]
7. Effect of Endotracheal Tube Size, Respiratory System Mechanics, and Ventilator Settings on Driving Pressure. Ilia S; van Schelven PD; Koopman AA; Blokpoel RGT; de Jager P; Burgerhof JGM; Markhorst DG; Kneyber MCJ Pediatr Crit Care Med; 2020 Jan; 21(1):e47-e51. PubMed ID: 31688716 [TBL] [Abstract][Full Text] [Related]
8. Respiratory mechanics during mechanical ventilation: a model study on the effects of leak around a tracheal tube. Kondo T; Matsumoto I; Lanteri CJ; Sly PD Pediatr Pulmonol; 1997 Dec; 24(6):423-8. PubMed ID: 9448234 [TBL] [Abstract][Full Text] [Related]
9. Elevated lung volume and alveolar pressure during jet ventilation of rabbits. Frantz ID; Close RH Am Rev Respir Dis; 1985 Jan; 131(1):134-8. PubMed ID: 3966700 [TBL] [Abstract][Full Text] [Related]
10. Improved flow and pressure capabilities of the Datex-Ohmeda SmartVent anesthesia ventilator. Katz JA; Kallet RH; Alonso JA; Marks JD J Clin Anesth; 2000 Feb; 12(1):40-7. PubMed ID: 10773507 [TBL] [Abstract][Full Text] [Related]
11. The dynostatic algorithm accurately calculates alveolar pressure on-line during ventilator treatment in children. Sondergaard S; Kárason S; Hanson A; Nilsson K; Wiklund J; Lundin S; Stenqvist O Paediatr Anaesth; 2003 May; 13(4):294-303. PubMed ID: 12753441 [TBL] [Abstract][Full Text] [Related]
12. Comparison of alveolar ventilation, oxygenation, pressure support, and respiratory system resistance in response to noninvasive versus conventional mechanical ventilation in foals. Hoffman AM; Kupcinskas RL; Paradis MR Am J Vet Res; 1997 Dec; 58(12):1463-7. PubMed ID: 9401700 [TBL] [Abstract][Full Text] [Related]
13. Elimination of apparatus dead space--a simple method for improving CO2 removal without increasing airway pressure. Larsson A Acta Anaesthesiol Scand; 1992 Nov; 36(8):796-9. PubMed ID: 1466217 [TBL] [Abstract][Full Text] [Related]
15. Open-lung protective ventilation with pressure control ventilation, high-frequency oscillation, and intratracheal pulmonary ventilation results in similar gas exchange, hemodynamics, and lung mechanics. Sedeek KA; Takeuchi M; Suchodolski K; Vargas SO; Shimaoka M; Schnitzer JJ; Kacmarek RM Anesthesiology; 2003 Nov; 99(5):1102-11. PubMed ID: 14576546 [TBL] [Abstract][Full Text] [Related]
16. Evaluation in animals of a system to estimate tracheal pressure from the endotracheal tube cuff. Wilder NA; Orr J; Westenskow D J Clin Monit; 1996 Jan; 12(1):11-6. PubMed ID: 8732811 [TBL] [Abstract][Full Text] [Related]
17. Compensating Artificial Airway Resistance via Active Expiration Assistance. Wirth S; Seywert L; Spaeth J; Schumann S Respir Care; 2016 Dec; 61(12):1597-1604. PubMed ID: 27555619 [TBL] [Abstract][Full Text] [Related]
18. Guidelines for inspiratory flow setting when measuring the pressure-volume relationship. Bensenor FE; Vieira JE; Auler JO Anesth Analg; 2003 Jul; 97(1):145-50, table of contents. PubMed ID: 12818957 [TBL] [Abstract][Full Text] [Related]
19. Airway anesthesia during positive and negative inspiratory pressure breathing in man. Lofaso F; Isabey D; Harf A; Scheid P Respir Physiol; 1992 Jul; 89(1):89-96. PubMed ID: 1518989 [TBL] [Abstract][Full Text] [Related]
20. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings. Hentschel R; Buntzel J; Guttmann J; Schumann S Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]