These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 18635619)
1. 3T high-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with parallel imaging. Lettau M; Sartor K; Heiland S; Hähnel S AJNR Am J Neuroradiol; 2009 Jan; 30(1):185-7. PubMed ID: 18635619 [TBL] [Abstract][Full Text] [Related]
2. 3-T contrast-enhanced MR angiography with parallel imaging in cerebral venous and sinus thrombosis. Lettau M; Laible M; Barrows RJ; Heiland S; Bendszus M; Hähnel S J Neuroradiol; 2011 Dec; 38(5):275-82. PubMed ID: 21353706 [TBL] [Abstract][Full Text] [Related]
3. Time-resolved MR angiography of the intracranial venous system: an alternative MR venography technique. Yiğit H; Turan A; Ergün E; Koşar P; Koşar U Eur Radiol; 2012 May; 22(5):980-9. PubMed ID: 22101744 [TBL] [Abstract][Full Text] [Related]
4. Comparative evaluation of 2D time-of-flight and 3D elliptic centric contrast-enhanced MR venography in patients with presumptive cerebral venous and sinus thrombosis. Klingebiel R; Bauknecht HC; Bohner G; Kirsch R; Berger J; Masuhr F Eur J Neurol; 2007 Feb; 14(2):139-43. PubMed ID: 17250720 [TBL] [Abstract][Full Text] [Related]
5. Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition. Nael K; Fenchel M; Salamon N; Duckwiler GR; Laub G; Finn JP; Villablanca JP Invest Radiol; 2006 Oct; 41(10):763-8. PubMed ID: 16971800 [TBL] [Abstract][Full Text] [Related]
6. Black-blood thrombus imaging (BTI): a contrast-free cardiovascular magnetic resonance approach for the diagnosis of non-acute deep vein thrombosis. Xie G; Chen H; He X; Liang J; Deng W; He Z; Ye Y; Yang Q; Bi X; Liu X; Li D; Fan Z J Cardiovasc Magn Reson; 2017 Jan; 19(1):4. PubMed ID: 28095878 [TBL] [Abstract][Full Text] [Related]
7. Comparison of real-time three-dimensional gadolinium-enhanced elliptic centric-ordered MR venography and two-dimensional time-of-flight MR venography of the intracranial venous system. Fu JH; Lai PH; Hsiao CC; Li SC; Weng MJ; Wang PC; Chen CK J Chin Med Assoc; 2010 Mar; 73(3):131-8. PubMed ID: 20230997 [TBL] [Abstract][Full Text] [Related]
8. Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas. Bozzao A; Finocchi V; Romano A; Ferrante M; Fasoli F; Trillò G; Ferrante L; Fantozzi LM Eur Radiol; 2005 Sep; 15(9):1790-6. PubMed ID: 15906036 [TBL] [Abstract][Full Text] [Related]
9. DANTE-SPACE: a new technical tool for DVT on 1.5T MRI. Zhuang G; Tang C; He X; Liang J; He Z; Ye Y; Deng W; Liu D; Chen H Int J Cardiovasc Imaging; 2019 Dec; 35(12):2231-2237. PubMed ID: 31446527 [TBL] [Abstract][Full Text] [Related]
10. Visualization of the internal cerebral veins on MR phase-sensitive imaging: comparison with 3D gadolinium-enhanced MR venography and fast-spoiled gradient recalled imaging. Sun J; Wang J; Jie L; Wang H; Gong X AJNR Am J Neuroradiol; 2011; 32(10):E191-3. PubMed ID: 21163881 [TBL] [Abstract][Full Text] [Related]
12. The value of T2*-weighted gradient-echo MRI for the diagnosis of cerebral venous sinus thrombosis. Ihn YK; Jung WS; Hwang SS Clin Imaging; 2013; 37(3):446-50. PubMed ID: 23068055 [TBL] [Abstract][Full Text] [Related]
14. A comparative study of magnetic resonance venography techniques for the evaluation of the internal jugular veins in multiple sclerosis patients. Rahman MT; Sethi SK; Utriainen DT; Hewett JJ; Haacke EM Magn Reson Imaging; 2013 Dec; 31(10):1668-76. PubMed ID: 23850076 [TBL] [Abstract][Full Text] [Related]
15. Combined MR Imaging for Pulmonary Embolism and Deep Venous Thrombosis by Contrast-enhanced MR Volume Interpolated Body Examination. Fu Q; Liu DX; Kong XC; Lei ZQ Curr Med Sci; 2020 Feb; 40(1):192-198. PubMed ID: 32166683 [TBL] [Abstract][Full Text] [Related]
16. Effects of Height and Blood Volume on Venous Enhancement After Gadolinium-Based Contrast Administration in MR Venography: A Paradigm Challenge and Implications for Clinical Imaging. Dehkharghani S; Williams TR; Qiu D; Saindane AM AJR Am J Roentgenol; 2016 Sep; 207(3):621-7. PubMed ID: 27304717 [TBL] [Abstract][Full Text] [Related]
17. Comparison of 3D TOF-MRA and 3D CE-MRA at 3T for imaging of intracranial aneurysms. Cirillo M; Scomazzoni F; Cirillo L; Cadioli M; Simionato F; Iadanza A; Kirchin M; Righi C; Anzalone N Eur J Radiol; 2013 Dec; 82(12):e853-9. PubMed ID: 24103356 [TBL] [Abstract][Full Text] [Related]
18. Preoperative evaluation of venous systems with 3-dimensional contrast-enhanced magnetic resonance venography in brain tumors: comparison with time-of-flight magnetic resonance venography and digital subtraction angiography. Lee JM; Jung S; Moon KS; Seo JJ; Kim IY; Jung TY; Lee JK; Kang SS Surg Neurol; 2005 Aug; 64(2):128-33; discussion 133-4. PubMed ID: 16051003 [TBL] [Abstract][Full Text] [Related]
19. Dual-echo arteriovenography imaging with 7T MRI. Bae KT; Park SH; Moon CH; Kim JH; Kaya D; Zhao T J Magn Reson Imaging; 2010 Jan; 31(1):255-61. PubMed ID: 20027596 [TBL] [Abstract][Full Text] [Related]
20. Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent. Huang SY; Kim CY; Miller MJ; Gupta RT; Lessne ML; Horvath JJ; Boll DT; Evans PD; Befera NT; Krishnan P; Chan JL; Merkle EM AJR Am J Roentgenol; 2013 Jul; 201(1):208-14. PubMed ID: 23789677 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]