BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

337 related articles for article (PubMed ID: 18640350)

  • 21. Characterizing the inflammatory reaction in explanted Medtronic Freestyle stentless porcine aortic bioprosthesis over a 6-year period.
    Nair V; Law KB; Li AY; Phillips KR; David TE; Butany J
    Cardiovasc Pathol; 2012; 21(3):158-68. PubMed ID: 21816627
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Aortic regurgitation due to perforation of the right coronary cusp 10 years after implantation of a freestyle stentless bioprosthesis.
    Okamoto Y; Katsu M; Matsumoto M
    J Card Surg; 2011 Nov; 26(6):613-4. PubMed ID: 21951139
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Aortic valve re-replacement after Bentall procedure with a biological valved conduit in a sheep model.
    Baraki H; Tudorache I; Hoeffler K; Khaladj N; Hagl C; Cebotari S; Haverich A; Shrestha M
    J Heart Valve Dis; 2012 Jan; 21(1):5-11. PubMed ID: 22474735
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Aortic root reconstruction in elderly patients].
    Ohtsubo S; Itoh T
    Kyobu Geka; 2005 Jul; 58(8 Suppl):695-700. PubMed ID: 16097620
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Aortic root replacement with a valved conduit containing a stented xenograft.
    Gatti G; Benussi B; Pappalardo A; Zingone B
    Eur J Cardiothorac Surg; 2008 Apr; 33(4):740-1. PubMed ID: 18262429
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dehiscence of the Freestyle stentless bioprosthesis.
    Schoof PH; Baur LH; Kappetein AP; Hazekamp MG; van Rijk-Zwikker GL; Huysmans HA
    Semin Thorac Cardiovasc Surg; 1999 Oct; 11(4 Suppl 1):133-8. PubMed ID: 10660181
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Aortic root replacement with a stentless bioprosthesis in osteogenesis imperfecta.
    Wakiyama H; Okada Y; Kitamura A; Imai Y
    J Heart Valve Dis; 2008 Mar; 17(2):197-9. PubMed ID: 18512491
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Stentless aortic valve implantation in heavily calcified aorta.
    Karimov JH; Cerillo AG; Solinas M; Murzi M; Latsuzbaia K; Bevilacqua S; Glauber M
    J Cardiovasc Med (Hagerstown); 2009 Oct; 10(10):813-4. PubMed ID: 19474759
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Aortopulmonary fistula due to perforation of the aortic wall of a freestyle stentless valve.
    Kameda Y; Mizuguchi K; Kuwata T; Mori T; Taniguchi S
    Ann Thorac Surg; 2004 Nov; 78(5):1827-9. PubMed ID: 15511487
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Aortic pseudo-aneurysm caused by complete dehiscence of the left coronary artery 7 years after a composite mechanical-valved conduit aortic root replacement (Bentall operation).
    Monney P; Pellaton C; Qanadli SD; Jeanrenaud X
    Eur Heart J; 2012 Jan; 33(1):60. PubMed ID: 21804108
    [No Abstract]   [Full Text] [Related]  

  • 31. Preassembled stentless valved-conduit for the replacement of the ascending aorta and aortic root.
    Bochenek-Klimczyk K; Lau KK; Galiñanes M; Sosnowski AW
    Interact Cardiovasc Thorac Surg; 2008 Dec; 7(6):964-8. PubMed ID: 18713779
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Fracture of Colvin-Galloway Future band causing a tear in the anterior mitral leaflet.
    Hartrumpf M; Stock UA; Kuehnel RU; Albes JM
    Ann Thorac Surg; 2006 May; 81(5):1879-80. PubMed ID: 16631693
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Late disruption of a Freestyle stentless bioprosthesis used for repair of sinus of Valsalva aneurysm of noncoronary cusp.
    Takami Y; Masumoto H; Fyfe-Kirschner B
    Ann Thorac Surg; 2007 Jun; 83(6):2210-3. PubMed ID: 17532431
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Acute bioprosthetic thrombosis immediately after aortic valve replacement.
    Patanè F; Sansone F; Campanella A; Asteggiano F; Rinaldi M
    J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):167-9. PubMed ID: 19194176
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Valsalva graft in the Bentall procedure: from mechanical valve to the BioValsalva, world's first biological aortic conduit.
    De Paulis R; Scaffa R; Maselli D; Weltert L; Salica A; Bellisario A
    Surg Technol Int; 2008; 17():216-21. PubMed ID: 18802905
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biological Bentall procedure with a Valsalva graft for a small aortic root.
    Usui A; Ueda Y
    Eur J Cardiothorac Surg; 2008 Jul; 34(1):224-5. PubMed ID: 18487057
    [No Abstract]   [Full Text] [Related]  

  • 38. Perceval sutureless valve in freestyle root: new surgical valve-in-valve therapy.
    Villa E; Messina A; Cirillo M; Brunelli F; Mhagna Z; Dalla Tomba M; Troise G
    Ann Thorac Surg; 2013 Dec; 96(6):e155-7. PubMed ID: 24296228
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Surgical technique of aortic valve replacement for small aortic annulus in elderly patients].
    Hata T; Fujiwara K; Furukawa H; Tsushima Y; Yoshitaka H; Kuinose M; Minami H; Ishida A; Tamura K; Totsugawa T; Kanemitsu H; Ozawa M
    Kyobu Geka; 2006 Apr; 59(4):283-7. PubMed ID: 16613145
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The use of a stentless porcine bioprosthesis to repair an ascending aortic aneurysm in combination with aortic valve regurgitation.
    Akpinar B; Sanisoğlu I; Konuralp C; Akay H; Güden M; Sönmez B
    Tex Heart Inst J; 1999; 26(3):195-7. PubMed ID: 10524742
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.