BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 18644178)

  • 1. A prospective observational study of 1000 vacuum assisted deliveries with the OmniCup device.
    Baskett TF; Fanning CA; Young DC
    J Obstet Gynaecol Can; 2008 Jul; 30(7):573-580. PubMed ID: 18644178
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Vacuum-assisted delivery: an analysis of traction force and maternal and neonatal outcomes.
    Vacca A
    Aust N Z J Obstet Gynaecol; 2006 Apr; 46(2):124-7. PubMed ID: 16638034
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Neonatal outcome following failed Kiwi OmniCup vacuum extraction.
    Edgar DC; Baskett TF; Young DC; O'Connell CM; Fanning CA
    J Obstet Gynaecol Can; 2012 Jul; 34(7):620-5. PubMed ID: 22742480
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A randomised controlled trial of a new handheld vacuum extraction device.
    Attilakos G; Sibanda T; Winter C; Johnson N; Draycott T
    BJOG; 2005 Nov; 112(11):1510-5. PubMed ID: 16225571
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A randomized comparison of assisted vaginal delivery by obstetric forceps and polyethylene vacuum cup.
    Williams MC; Knuppel RA; O'Brien WF; Weiss A; Kanarek KS
    Obstet Gynecol; 1991 Nov; 78(5 Pt 1):789-94. PubMed ID: 1923198
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A randomised controlled trial of two instruments for vacuum-assisted delivery (Vacca Re-Usable OmniCup and the Bird anterior and posterior cups) to compare failure rates, safety and use effectiveness.
    Mola GD; Kuk JM
    Aust N Z J Obstet Gynaecol; 2010 Jun; 50(3):246-52. PubMed ID: 20618242
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mode of delivery in nulliparous women and neonatal intracranial injury.
    Werner EF; Janevic TM; Illuzzi J; Funai EF; Savitz DA; Lipkind HS
    Obstet Gynecol; 2011 Dec; 118(6):1239-1246. PubMed ID: 22105252
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Maternal and neonatal outcomes in vacuum-assisted delivery with the Kiwi OmniCup and Malmström metal cup.
    Turkmen S
    J Obstet Gynaecol Res; 2015 Feb; 41(2):207-13. PubMed ID: 25255995
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Kiwi Omnicup versus Malmstrom metal cup in vacuum assisted delivery: a randomized comparative trial.
    Ismail NA; Saharan WS; Zaleha MA; Jaafar R; Muhammad JA; Razi ZR
    J Obstet Gynaecol Res; 2008 Jun; 34(3):350-3. PubMed ID: 18686348
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Vacuum extraction: does duration predict scalp injury?
    Teng FY; Sayre JW
    Obstet Gynecol; 1997 Feb; 89(2):281-5. PubMed ID: 9015036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neonatal complications in vacuum-assisted vaginal delivery: are they associated with number of pulls, cup detachments, and duration of vacuum application?
    Ghidini A; Stewart D; Pezzullo JC; Locatelli A
    Arch Gynecol Obstet; 2017 Jan; 295(1):67-73. PubMed ID: 27677283
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Head injuries after instrumental vaginal deliveries.
    Doumouchtsis SK; Arulkumaran S
    Curr Opin Obstet Gynecol; 2006 Apr; 18(2):129-34. PubMed ID: 16601472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Obstetric correlates of neonatal retinal hemorrhage.
    Williams MC; Knuppel RA; O'Brien WF; Weiss A; Spellacy WN; Pietrantoni M
    Obstet Gynecol; 1993 May; 81(5 ( Pt 1)):688-94. PubMed ID: 8469455
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cohort study of Silastic obstetric vacuum cup deliveries: II. Unsuccessful vacuum extraction.
    Berkus MD; Ramamurthy RS; O'Connor PS; Brown KJ; Hayashi RH
    Obstet Gynecol; 1986 Nov; 68(5):662-6. PubMed ID: 3763080
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cohort study of silastic obstetric vacuum cup deliveries: I. Safety of the instrument.
    Berkus MD; Ramamurthy RS; O'Connor PS; Brown K; Hayashi RH
    Obstet Gynecol; 1985 Oct; 66(4):503-9. PubMed ID: 3900836
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of mode of delivery in nulliparous women on neonatal intracranial injury.
    Towner D; Castro MA; Eby-Wilkens E; Gilbert WM
    N Engl J Med; 1999 Dec; 341(23):1709-14. PubMed ID: 10580069
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Neonatal subgaleal hemorrhage and its relationship to delivery by vacuum extraction.
    Uchil D; Arulkumaran S
    Obstet Gynecol Surv; 2003 Oct; 58(10):687-93. PubMed ID: 14515066
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Short-term maternal and neonatal outcomes by mode of delivery. A case-controlled study.
    Benedetto C; Marozio L; Prandi G; Roccia A; Blefari S; Fabris C
    Eur J Obstet Gynecol Reprod Biol; 2007 Nov; 135(1):35-40. PubMed ID: 17126475
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Kiwi omnicup handheld versus Mityvac M-style conventional vacuum system: a retrospective observational study.
    Weissbach T; Hag-Yahia N; Ovadia M; Tzadikevitch Geffen K; Weitzner O; Biron-Shental T
    J Matern Fetal Neonatal Med; 2018 Dec; 31(23):3178-3182. PubMed ID: 28793827
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial.
    Equy V; David-Tchouda S; Dreyfus M; Riethmuller D; Vendittelli F; Cabaud V; Langer B; Margier J; Bosson JL; Schaal JP
    BMC Pregnancy Childbirth; 2015 Dec; 15():332. PubMed ID: 26666981
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.