BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 1864550)

  • 1. Mononuclear cell (MNC) concentration from the marrow harvest by automatic system.
    Franchini E; Porlezza M
    Haematologica; 1991 Mar; 76 Suppl 1():15-7. PubMed ID: 1864550
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effective concentration of bone marrow mononuclear cells using density gradient separation within an automated cell separator.
    Baker PK; Rhodes EG; Duguid JK
    Transfus Sci; 1992 Jul; 13(3):353-6. PubMed ID: 10148131
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Separation of adult bone marrow mononuclear cells using the automated closed separation system Sepax.
    Aktas M; Radke TF; Strauer BE; Wernet P; Kogler G
    Cytotherapy; 2008; 10(2):203-11. PubMed ID: 18368599
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Semiautomated autologous bone marrow processing for transplantation.
    Pierelli L; Menichella G; Paoloni A; Serafini R; Vittori M; Foddai ML; Meoni F; Rossi PL; Leone G; Mango G
    Haematologica; 1991 Mar; 76 Suppl 1():10-1. PubMed ID: 1677909
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Concentration of bone marrow total nucleated cells by a point-of-care device provides a high yield and preserves their functional activity.
    Hermann PC; Huber SL; Herrler T; von Hesler C; Andrassy J; Kevy SV; Jacobson MS; Heeschen C
    Cell Transplant; 2008; 16(10):1059-69. PubMed ID: 18351022
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid and automated processing of bone marrow grafts without Ficoll density gradient for transplantation of cryopreserved autologous or ABO-incompatible allogeneic bone marrow.
    Schanz U; Gmür J
    Bone Marrow Transplant; 1992 Dec; 10(6):507-13. PubMed ID: 1490200
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison between two different procedures for bone marrow processing: a semiautomated procedure vs manual starch sedimentation.
    Menichella G; Pierelli L; Serafini R; Foddai ML; Vittori M; Paoloni A; De Martini M; Rossi PL; Mango G; Bizzi B
    Haematologica; 1991 Mar; 76 Suppl 1():12-4. PubMed ID: 1713872
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Human bone marrow processing using Cobe 2991 and CS 3000 blood cell separators for further ex vivo manipulation.
    Angelini A; Dragani A; Iacone A; D'Antonio D; Accorsi P; Quaglietta AM; Berardi A; Fioritoni G; Di Bartolomeo P; D'Emilio G
    Haematologica; 1990; 75 Suppl 1():43-7. PubMed ID: 2351343
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors affecting volume reduction and red blood cell depletion of bone marrow on the COBE Spectra cell separator before haematopoietic stem cell transplantation.
    Guttridge MG; Sidders C; Booth-Davey E; Pamphilon D; Watt SM
    Bone Marrow Transplant; 2006 Aug; 38(3):175-81. PubMed ID: 16770313
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Red cell salvage and reinfusion in pediatric bone marrow donors.
    Kletzel M; Olszewski M; Danner-Koptik K; Coyne K; Haut P
    Bone Marrow Transplant; 1999 Aug; 24(4):385-8. PubMed ID: 10467327
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Semiautomated processing of bone marrow grafts for transplantation.
    English D; Lamberson R; Graves V; Akard LP; McCarthy LJ; Jansen J
    Transfusion; 1989 Jan; 29(1):12-6. PubMed ID: 2643209
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Density-gradient separation for 4-hydroperoxycyclophosphamide purging of autologous bone marrow grafts.
    Rowley S; Davis J; Braine H; Jones R; Yeager A; Saral R; Santos G
    Prog Clin Biol Res; 1990; 333():369-77. PubMed ID: 2308991
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Erythrocyte removal from bone marrow by density gradient separation using the COBE 2991 cell processor with the triple-bag processing set].
    Cappellesso-Fleury S; Rage C; Tschaggeny F; Gaudé J; Gomez M; Bourin P
    Transfus Clin Biol; 2009 Mar; 16(1):43-9. PubMed ID: 19200762
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Autologous bone marrow processing for autotransplantation using an automated cell processor and a semiautomated procedure.
    Pierelli L; Menichella G; Serafini R; de Martini M; Paoloni A; Foddai ML; Scambia G; Benedetti Panici PL; Mancuso S; Leone G
    Bone Marrow Transplant; 1991 May; 7(5):355-61. PubMed ID: 2070144
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous flow cell separator use for bone marrow processing.
    Baker PK; Rhodes EG; Duguid JK
    Transfus Sci; 1991; 12(3):183-7. PubMed ID: 10150913
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bone marrow transplantation with major ABO blood group incompatibility using automated removal of red blood cells from incompatible bone marrow by CS 3000 plus.
    O-Charoen R; Soiprasert P; Chaisiripoomkere W; Jootar S; Chiewsilp P
    Transplant Proc; 1994 Aug; 26(4):2352-3. PubMed ID: 8066772
    [No Abstract]   [Full Text] [Related]  

  • 17. Autologous bone marrow transplantation in non-Hodgkin's lymphomas: prediction of mononuclear cell yield in bone marrow harvests.
    Rinaldi C; Savignano C; Silvestri F; Geromin A; Cerno M; Fanin R; Biffoni F; Baccarani M
    Haematologica; 1995; 80(5):443-7. PubMed ID: 8566888
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Processing of bone marrow for transplantation: development of a mononuclear cell enrichment protocol.
    Hollingsworth KL; Williams SF; Blake MS; Pothiawala M; Mick R; Larson RA; Bender JG
    Prog Clin Biol Res; 1994; 389():695-704. PubMed ID: 7700937
    [No Abstract]   [Full Text] [Related]  

  • 19. Processing bone marrow with a semiautomated cell processor for pediatric transplants: a comparison of two buffy coat preparation methods.
    Kletzel M; Olszewski ML; Dunn GF
    J Hematother; 1994; 3(1):59-64. PubMed ID: 7922010
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated bone marrow concentration using the Fresenius AS 104 blood cell separator.
    Zingsem J; Weisbach V; Zimmermann R; Zeiler T; Mitschulat H; Beyer J; Eckstein R
    Beitr Infusionsther Transfusionsmed; 1994; 32():355-9. PubMed ID: 9422118
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.