260 related articles for article (PubMed ID: 18646776)
21. Trace metals analysis in estuarine and seawater by ICP-MS using on line preconcentration and matrix elimination with chelating resin.
Nicolaı M; Rosin C; Tousset N; Nicolai Y
Talanta; 1999 Sep; 50(2):433-44. PubMed ID: 18967734
[TBL] [Abstract][Full Text] [Related]
22. Preparation of monolithic chelating adsorbent inside a syringe filter tip for solid phase microextraction of trace elements in natural water prior to their determination by ICP-MS.
Rahmi D; Takasaki Y; Zhu Y; Kobayashi H; Konagaya S; Haraguchi H; Umemura T
Talanta; 2010 Jun; 81(4-5):1438-45. PubMed ID: 20441920
[TBL] [Abstract][Full Text] [Related]
23. A simple and rapid method for isotopic analysis of nickel, copper, and zinc in seawater using chelating extraction and anion exchange.
Takano S; Tanimizu M; Hirata T; Shin KC; Fukami Y; Suzuki K; Sohrin Y
Anal Chim Acta; 2017 May; 967():1-11. PubMed ID: 28390480
[TBL] [Abstract][Full Text] [Related]
24. Determination of rare earth elements and other trace elements (Y, Mn, Co, Cr) in seawater using Tm addition and Mg(OH)₂ co-precipitation.
Freslon N; Bayon G; Birot D; Bollinger C; Barrat JA
Talanta; 2011 Jul; 85(1):582-7. PubMed ID: 21645745
[TBL] [Abstract][Full Text] [Related]
25. Determination of ultratrace levels of dissolved metals in seawater by reaction cell inductively coupled plasma mass spectrometry after ammonia induced magnesium hydroxide coprecipitation.
Ardini F; Magi E; Grotti M
Anal Chim Acta; 2011 Nov; 706(1):84-8. PubMed ID: 21995913
[TBL] [Abstract][Full Text] [Related]
26. Determination of REEs in seawater by ICP-MS after on-line preconcentration using a syringe-driven chelating column.
Zhu Y; Umemura T; Haraguchi H; Inagaki K; Chiba K
Talanta; 2009 May; 78(3):891-5. PubMed ID: 19269446
[TBL] [Abstract][Full Text] [Related]
27. Low Blank Preconcentration Technique for the Determination of Lead, Copper, and Cadmium in Small-Volume Seawater Samples by Isotope Dilution ICPMS.
Wu J; Boyle EA
Anal Chem; 1997 Jul; 69(13):2464-70. PubMed ID: 21639382
[TBL] [Abstract][Full Text] [Related]
28. On-line collection/concentration and determination of transition and rare-earth metals in water samples using Multi-Auto-Pret system coupled with inductively coupled plasma-atomic emission spectrometry.
Katarina RK; Oshima M; Motomizu S
Talanta; 2009 May; 78(3):1043-50. PubMed ID: 19269470
[TBL] [Abstract][Full Text] [Related]
29. MULTIELEMENT SOLID PHASE PRECONCENTRATION USING A CHELATING RESIN OF STYRENE DIVINYLBENZENE COPOLYMER AND APPLICATION TO ANALYSIS OF SEAWATER AND FISH OTOLITHS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP�MS).
Zereen F; Yilmaz V; Arslan Z
Anal Lett; 2014; 47(1):58-76. PubMed ID: 24976635
[TBL] [Abstract][Full Text] [Related]
30. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions.
Tu Z; He Q; Chang X; Hu Z; Gao R; Zhang L; Li Z
Anal Chim Acta; 2009 Sep; 649(2):252-7. PubMed ID: 19699402
[TBL] [Abstract][Full Text] [Related]
31. Simultaneous on-line pre-concentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma mass spectrometry using silica gel modified with niobium(V) oxide.
Maltez HF; Vieira MA; Ribeiro AS; Curtius AJ; Carasek E
Talanta; 2008 Jan; 74(4):586-92. PubMed ID: 18371679
[TBL] [Abstract][Full Text] [Related]
32. Solid-phase extraction of Cu, Co and Pb on oxidized single-walled carbon nanotubes and their determination by inductively coupled plasma mass spectrometry.
Chen S; Liu C; Yang M; Lu D; Zhu L; Wang Z
J Hazard Mater; 2009 Oct; 170(1):247-51. PubMed ID: 19473762
[TBL] [Abstract][Full Text] [Related]
33. Trace metal determination in natural waters by automated solid phase extraction system and ICP-MS: the influence of low level Mg and Ca.
Wang BS; Lee CP; Ho TY
Talanta; 2014 Oct; 128():337-44. PubMed ID: 25059169
[TBL] [Abstract][Full Text] [Related]
34. A new chelating sorbent for metal ion extraction under high saline conditions.
Prabhakaran D; Subramanian MS
Talanta; 2003 May; 59(6):1227-36. PubMed ID: 18969013
[TBL] [Abstract][Full Text] [Related]
35. Enrichment with air-sandwiched method of on-line collection/concentration using chelating resin and simultaneous determination of trace elements by inductively coupled plasma atomic emission spectrometry.
Noguchi O; Oshima M; Motomizu S
Talanta; 2009 Jun; 78(4-5):1235-9. PubMed ID: 19362181
[TBL] [Abstract][Full Text] [Related]
36. Determination of ultra-trace level of
Wysocka I; Vassileva E
Anal Chim Acta; 2018 Feb; 1000():144-154. PubMed ID: 29289303
[TBL] [Abstract][Full Text] [Related]
37. Simultaneous and selective preconcentration of trace Cu and Ag by one-step displacement cloud point extraction for FAAS determination.
Gao Y; Wu P; Li W; Xuan Y; Hou X
Talanta; 2010 Apr; 81(1-2):586-90. PubMed ID: 20188966
[TBL] [Abstract][Full Text] [Related]
38. Application of cotton as a solid phase extraction sorbent for on-line preconcentration of copper in water samples prior to inductively coupled plasma optical emission spectrometry determination.
Faraji M; Yamini Y; Shariati S
J Hazard Mater; 2009 Jul; 166(2-3):1383-8. PubMed ID: 19157691
[TBL] [Abstract][Full Text] [Related]
39. Determination of trace impurities in high-purity iron using salting-out of polyoxyethylene-type surfactants.
Matsumiya H; Sakane Y; Hiraide M
Anal Chim Acta; 2009 Oct; 653(1):86-90. PubMed ID: 19800478
[TBL] [Abstract][Full Text] [Related]
40. High-precision determination of the isotopic composition of dissolved iron in iron depleted seawater by double spike multicollector-ICPMS.
Lacan F; Radic A; Labatut M; Jeandel C; Poitrasson F; Sarthou G; Pradoux C; Chmeleff J; Freydier R
Anal Chem; 2010 Sep; 82(17):7103-11. PubMed ID: 20701301
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]