These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

339 related articles for article (PubMed ID: 18647269)

  • 21. The effects of head flexion on airway seal, quality of ventilation and orogastric tube placement using the ProSeal laryngeal mask airway.
    Xue FS; Mao P; Liu HP; Yang QY; Li CW; He N; Xu YC; Liao X
    Anaesthesia; 2008 Sep; 63(9):979-85. PubMed ID: 18699873
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A comparison of the disposable Ambu AuraOnce Laryngeal Mask with the reusable LMA Classic laryngeal mask airway.
    Sudhir G; Redfern D; Hall JE; Wilkes AR; Cann C
    Anaesthesia; 2007 Jul; 62(7):719-22. PubMed ID: 17567349
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pressure-controlled ventilation is superior to volume-controlled ventilation with a laryngeal mask airway in children.
    Bordes M; Semjen F; Degryse C; Bourgain JL; Cros AM
    Acta Anaesthesiol Scand; 2007 Jan; 51(1):82-5. PubMed ID: 17073863
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of nitrous oxide on laryngeal mask cuff pressure.
    Ouellette RG
    AANA J; 2000 Oct; 68(5):411-4. PubMed ID: 11759125
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A prospective, randomized comparison of cobra perilaryngeal airway and laryngeal mask airway unique in pediatric patients.
    Szmuk P; Ghelber O; Matuszczak M; Rabb MF; Ezri T; Sessler DI
    Anesth Analg; 2008 Nov; 107(5):1523-30. PubMed ID: 18931209
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of 2 cuff inflation methods of laryngeal mask airway Classic for safe use without cuff manometer in adults.
    Kim MS; Lee JR; Shin YS; Chung JW; Lee KH; Ahn KR
    Am J Emerg Med; 2014 Mar; 32(3):237-42. PubMed ID: 24360025
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of cuffed, uncuffed tracheal tubes and laryngeal mask airways in low flow pressure controlled ventilation in children.
    Engelhardt T; Johnston G; Kumar MM
    Paediatr Anaesth; 2006 Feb; 16(2):140-3. PubMed ID: 16430409
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prospective clinical and fiberoptic evaluation of the Supreme laryngeal mask airway.
    Timmermann A; Cremer S; Eich C; Kazmaier S; Bräuer A; Graf BM; Russo SG
    Anesthesiology; 2009 Feb; 110(2):262-5. PubMed ID: 19194153
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparison of postoperative sore throat after use of laryngeal mask airway and tracheal tube.
    Mizutamari E; Yano T; Ushijima K; Ito A; Anraku S; Tanimoto H; Terasaki H
    J Anesth; 2004; 18(3):151-7. PubMed ID: 15290411
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A randomized crossover comparison between the Laryngeal Mask Airway-Unique™ and the air-Q intubating laryngeal airway in children.
    Jagannathan N; Sohn LE; Mankoo R; Langen KE; Mandler T
    Paediatr Anaesth; 2012 Feb; 22(2):161-7. PubMed ID: 21917058
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [An auto control comparison of the use of ProSeal laryngeal mask airway and standard laryngeal mask airway for positive pressure ventilation].
    Li CW; Xue FS; Mao P; Xu YC; Liu Y; Zhang GH; Liu KP; Sun HT
    Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2007 Feb; 19(2):81-5. PubMed ID: 17326908
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A cohort evaluation of the pediatric ProSeal laryngeal mask airway in 100 children.
    Kelly F; Sale S; Bayley G; Cook T; Stoddart P; White M
    Paediatr Anaesth; 2008 Oct; 18(10):947-51. PubMed ID: 18647270
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A comparison of the Soft Seal disposable and the Classic re-usable laryngeal mask airway.
    Shafik MT; Bahlman BU; Hall JE; Ali MS
    Anaesthesia; 2006 Feb; 61(2):178-81. PubMed ID: 16430570
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Prospective randomized comparison of the new Laryngeal Tube Suction LTS II and the LMA-ProSeal for elective surgical interventions.
    Genzwuerker HV; Altmayer S; Hinkelbein J; Gernoth C; Viergutz T; Ocker H
    Acta Anaesthesiol Scand; 2007 Nov; 51(10):1373-7. PubMed ID: 17944641
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cuffed endotracheal tubes in infants and children: should we routinely measure the cuff pressure?
    Tobias JD; Schwartz L; Rice J; Jatana K; Kang DR
    Int J Pediatr Otorhinolaryngol; 2012 Jan; 76(1):61-3. PubMed ID: 22024576
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The PAxpress is an effective ventilatory device but has an 18% failure rate for flexible lightwand-guided tracheal intubation in anesthetized paralyzed patients.
    Dimitriou V; Voyagis GS; Iatrou C; Brimacombe J
    Can J Anaesth; 2003 May; 50(5):495-500. PubMed ID: 12734160
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Application of Minimum Effective Cuff Inflating Volume for Laryngeal Mask Airway and its Impact on Postoperative Pharyngeal Complications.
    Li BB; Yan J; Zhou HG; Hao J; Liu AJ; Ma ZL
    Chin Med J (Engl); 2015 Oct; 128(19):2570-6. PubMed ID: 26415792
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Randomized prospective study comparing the laryngeal tube suction II with the ProSeal laryngeal mask airway in anesthetized and paralyzed patients.
    Kikuchi T; Kamiya Y; Ohtsuka T; Miki T; Goto T
    Anesthesiology; 2008 Jul; 109(1):54-60. PubMed ID: 18580172
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Tracheal sealing by auto-inflation in tracheal tube cuffs.
    Weiss M; Shorten G; Stutz K; Bernet V
    Paediatr Anaesth; 2007 Mar; 17(3):243-8. PubMed ID: 17263739
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Clinical comparison of the reusable LMA Classic laryngeal mask and the disposable Soft Seal mask in adult patients].
    López AM; Valero R; Pons M; Salvador L; de Riva N; Gomar C
    Rev Esp Anestesiol Reanim; 2007 Oct; 54(8):462-8. PubMed ID: 17993094
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.