These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 18651020)

  • 41. Comparison of long-term outcomes of bare metal or drug-eluting stent implantation in standard versus off-label coronary narrowings.
    Harjai KJ; Orshaw P; Boura J; Sporn D
    Am J Cardiol; 2009 Jun; 103(11):1537-45. PubMed ID: 19463512
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Influence of a paclitaxel coated balloon in combination with a bare metal stent on restenosis and endothelial function: comparison with a drug eluting stent and a bare metal stent.
    Clever YP; Cremers B; Speck U; Dietz U; Böhm M; Scheller B
    Catheter Cardiovasc Interv; 2014 Aug; 84(2):323-31. PubMed ID: 23996969
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Bare metal stent implantation in large-sized unprotected left main coronary artery stenosis in the drug-eluting stent era.
    Kosuga K; Okada M; Takeda S; Hata T; Takeuchi Y; Kawata Y; Ishii M; Harita K; Nishio S; Ikeguchi S; Kyo E; Tsuji T
    Cardiovasc Interv Ther; 2010 Jul; 25(2):65-71. PubMed ID: 24122464
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Validation and comparison of drug eluting stent to bare metal stent for restenosis rates following vertebral artery ostium stenting: A single-center real-world study.
    Li L; Wang X; Yang B; Wang Y; Gao P; Chen Y; Zhu F; Ma Y; Chi H; Zhang X; Bai X; Feng Y; Dmytriw AA; Hong T; Hua Y; Jiao L; Ling F
    Interv Neuroradiol; 2020 Oct; 26(5):629-636. PubMed ID: 32799746
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Predictor of subsequent target lesion revascularization in patients with drug-eluting stent restenosis undergoing percutaneous coronary intervention.
    Takasawa Y; Iijima R; Shiba M; Nakamura M; Sugi K
    J Cardiol; 2010 May; 55(3):391-6. PubMed ID: 20350511
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Outcome differences with the use of drug-eluting stents for the treatment of in-stent restenosis of bare-metal stents versus drug-eluting stents.
    Steinberg DH; Gaglia MA; Pinto Slottow TL; Roy P; Bonello L; De Labriolle A; Lemesle G; Torguson R; Kineshige K; Xue Z; Suddath WO; Kent KM; Satler LF; Pichard AD; Lindsay J; Waksman R
    Am J Cardiol; 2009 Feb; 103(4):491-5. PubMed ID: 19195508
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Six-month clinical and angiographic results of the STENTYS® self-apposing stent in bifurcation lesions.
    Verheye S; Ramcharitar S; Grube E; Schofer JJ; Witzenbichler B; Kovac J; Hauptmann KE; Agostoni P; Wiemer M; Lefèvre T; Spaargaren R; Serruys PW; García-García HM; van Geuns RJ
    EuroIntervention; 2011 Sep; 7(5):580-7. PubMed ID: 21930462
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Angiographic and clinical outcome of percutaneous coronary intervention for in-stent restenosis of bifurcated lesions.
    Coroleu SF; De Vita M; Burzotta F; Trani C; Porto I; Niccoli G; Leone AM; Tommasino A; Talarico GP; Schiavoni G; Crea F
    EuroIntervention; 2012 Oct; 8(6):701-7. PubMed ID: 23086788
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A multicenter, randomized study to test immunosuppressive therapy with oral prednisone for the prevention of restenosis after percutaneous coronary interventions: cortisone plus BMS or DES versus BMS alone to eliminate restenosis (CEREA-DES) - study design and rationale.
    Ribichini F; Tomai F; De Luca G; Boccuzzi G; Presbitero P; Pesarini G; Ferrero V; Ghini AS; Pastori F; De Luca L; Zavalloni D; Soregaroli D; Garbo R; Franchi E; Marino P; Minelli M; Vassanelli C
    J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):192-9. PubMed ID: 19377384
    [TBL] [Abstract][Full Text] [Related]  

  • 50. SeQuentPlease World Wide Registry: clinical results of SeQuent please paclitaxel-coated balloon angioplasty in a large-scale, prospective registry study.
    Wöhrle J; Zadura M; Möbius-Winkler S; Leschke M; Opitz C; Ahmed W; Barragan P; Simon JP; Cassel G; Scheller B
    J Am Coll Cardiol; 2012 Oct; 60(18):1733-8. PubMed ID: 23040575
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Firebird and cypher sirolimus-eluting stents and bare metal stents in treatment of very long coronary lesions.
    Fan L; Chen LL; Lin CG; Peng YF; Zheng XC; Luo YK; Zhang FL; Chen JH; Yan XP; Huang ZR
    Chin Med J (Engl); 2008 Aug; 121(16):1518-23. PubMed ID: 18982862
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Impact of significant chronic kidney disease on long-term clinical outcomes after drug-eluting stent versus bare metal stent implantation.
    Jeong YH; Hong MK; Lee CW; Park DW; Kim YH; Kim JJ; Park SW; Park SJ
    Int J Cardiol; 2008 Mar; 125(1):36-40. PubMed ID: 17521753
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study.
    Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W
    EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Efficacy comparison between drug-eluting stents versus cutting balloon angioplasty followed by bare metal stents for the treatment of ostial lesions of the left anterior descending coronary artery].
    Chen JL; Gao LJ; Gao RL; Yang YJ; Qin XW; Qiao SB; Xu B; Yao M; Liu HB; Wu YJ; Yuan JQ; Chen J
    Zhonghua Xin Xue Guan Bing Za Zhi; 2008 Aug; 36(8):702-5. PubMed ID: 19100110
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Two-year clinical follow up of coronary drug-eluting stent in patients at high risk for coronary restenosis.
    Azzarelli S; Amico F; Galassi AR; Giacoppo M; Argentino V; Fiscella A
    J Invasive Cardiol; 2008 Feb; 20(2):62-6. PubMed ID: 18252969
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Long-term efficacy and safety of drug-eluting stent implantation for patients with multiple coronary chronic total occlusions.
    Zhang J; Han YL; Li Y; Wang SL; Jing QM; Wang XZ; Ma YY; Luan B; Wang G; Wang B
    Chin Med J (Engl); 2010 Apr; 123(7):789-93. PubMed ID: 20497665
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Drug Coated Balloon Is Less Effective for Treatment of DES In-Stent Restenosis Both in Native Coronary Arteries and Saphenous Vein Grafts: Results From a Bicenter Registry.
    Resch M; Ostheim P; Endemann DH; Debl K; Buchner S; Birner C; Maier LS; Kerber S; Luchner A; Griese DP
    J Interv Cardiol; 2016 Oct; 29(5):461-468. PubMed ID: 27477024
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Differences in tissue characterization of restenotic neointima between sirolimus-eluting stent and bare-metal stent: integrated backscatter intravascular ultrasound analysis for in-stent restenosis.
    Ando H; Amano T; Takashima H; Harada K; Kitagawa K; Suzuki A; Kunimura A; Shimbo Y; Harada K; Yoshida T; Kato B; Uetani T; Kato M; Matsubara T; Kumagai S; Yoshikawa D; Isobe S; Ishii H; Murohara T
    Eur Heart J Cardiovasc Imaging; 2013 Oct; 14(10):996-1001. PubMed ID: 23341147
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A comparison of clinical presentations, angiographic patterns and outcomes of in-stent restenosis between bare metal stents and drug eluting stents.
    Rathore S; Kinoshita Y; Terashima M; Katoh O; Matsuo H; Tanaka N; Kimura M; Tsuchikane E; Nasu K; Ehara M; Asakura K; Asakura Y; Suzuki T
    EuroIntervention; 2010 Feb; 5(7):841-6. PubMed ID: 20142201
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Long-term clinical outcome in patients with small vessel disease treated with drug-eluting versus bare-metal stenting.
    Puymirat E; Mangiacapra F; Peace A; Sharif F; Conte M; Bartunek J; Vanderheyden M; Wijns W; de Bruyne B; Barbato E
    Am Heart J; 2011 Nov; 162(5):907-13. PubMed ID: 22093208
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.