BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

252 related articles for article (PubMed ID: 18665430)

  • 1. Fluorophore-conjugated anti-CEA antibody for the intraoperative imaging of pancreatic and colorectal cancer.
    Kaushal S; McElroy MK; Luiken GA; Talamini MA; Moossa AR; Hoffman RM; Bouvet M
    J Gastrointest Surg; 2008 Nov; 12(11):1938-50. PubMed ID: 18665430
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Toward Curative Fluorescence-Guided Surgery of Pancreatic Cancer.
    Bouvet M; Hoffman RM
    Hepatogastroenterology; 2015 May; 62(139):715-22. PubMed ID: 26897960
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fluorescence-guided surgery with a fluorophore-conjugated antibody to carcinoembryonic antigen (CEA), that highlights the tumor, improves surgical resection and increases survival in orthotopic mouse models of human pancreatic cancer.
    Metildi CA; Kaushal S; Pu M; Messer KA; Luiken GA; Moossa AR; Hoffman RM; Bouvet M
    Ann Surg Oncol; 2014 Apr; 21(4):1405-11. PubMed ID: 24499827
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluorescently labeled chimeric anti-CEA antibody improves detection and resection of human colon cancer in a patient-derived orthotopic xenograft (PDOX) nude mouse model.
    Metildi CA; Kaushal S; Luiken GA; Talamini MA; Hoffman RM; Bouvet M
    J Surg Oncol; 2014 Apr; 109(5):451-8. PubMed ID: 24249594
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hand-held high-resolution fluorescence imaging system for fluorescence-guided surgery of patient and cell-line pancreatic tumors growing orthotopically in nude mice.
    Hiroshima Y; Maawy A; Sato S; Murakami T; Uehara F; Miwa S; Yano S; Momiyama M; Chishima T; Tanaka K; Bouvet M; Endo I; Hoffman RM
    J Surg Res; 2014 Apr; 187(2):510-7. PubMed ID: 24373959
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Successful fluorescence-guided surgery on human colon cancer patient-derived orthotopic xenograft mouse models using a fluorophore-conjugated anti-CEA antibody and a portable imaging system.
    Hiroshima Y; Maawy A; Metildi CA; Zhang Y; Uehara F; Miwa S; Yano S; Sato S; Murakami T; Momiyama M; Chishima T; Tanaka K; Bouvet M; Endo I; Hoffman RM
    J Laparoendosc Adv Surg Tech A; 2014 Apr; 24(4):241-7. PubMed ID: 24494971
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tumor-Specific Labeling of Pancreatic Cancer Using a Humanized Anti-CEA Antibody Conjugated to a Near-Infrared Fluorophore.
    Lwin TM; Murakami T; Miyake K; Yazaki PJ; Shivley JE; Hoffman RM; Bouvet M
    Ann Surg Oncol; 2018 Apr; 25(4):1079-1085. PubMed ID: 29372363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Imaging of primary and metastatic pancreatic cancer using a fluorophore-conjugated anti-CA19-9 antibody for surgical navigation.
    McElroy M; Kaushal S; Luiken GA; Talamini MA; Moossa AR; Hoffman RM; Bouvet M
    World J Surg; 2008 Jun; 32(6):1057-66. PubMed ID: 18264829
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SGM-101: An innovative near-infrared dye-antibody conjugate that targets CEA for fluorescence-guided surgery.
    Gutowski M; Framery B; Boonstra MC; Garambois V; Quenet F; Dumas K; Scherninski F; Cailler F; Vahrmeijer AL; Pèlegrin A
    Surg Oncol; 2017 Jun; 26(2):153-162. PubMed ID: 28577721
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative detection of colorectal and pancreatic liver metastases using SGM-101, a fluorescent antibody targeting CEA.
    Meijer RPJ; de Valk KS; Deken MM; Boogerd LSF; Hoogstins CES; Bhairosingh SS; Swijnenburg RJ; Bonsing BA; Framery B; Fariña Sarasqueta A; Putter H; Hilling DE; Burggraaf J; Cailler F; Mieog JSD; Vahrmeijer AL
    Eur J Surg Oncol; 2021 Mar; 47(3 Pt B):667-673. PubMed ID: 33158638
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effective fluorescence-guided surgery of liver metastasis using a fluorescent anti-CEA antibody.
    Hiroshima Y; Lwin TM; Murakami T; Mawy AA; Kuniya T; Chishima T; Endo I; Clary BM; Hoffman RM; Bouvet M
    J Surg Oncol; 2016 Dec; 114(8):951-958. PubMed ID: 27696448
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tumor-specific near-infrared nanobody probe rapidly labels tumors in an orthotopic mouse model of pancreatic cancer.
    Lwin TM; Hernot S; Hollandsworth H; Amirfakhri S; Filemoni F; Debie P; Hoffman RM; Bouvet M
    Surgery; 2020 Jul; 168(1):85-91. PubMed ID: 32370916
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety and effectiveness of SGM-101, a fluorescent antibody targeting carcinoembryonic antigen, for intraoperative detection of colorectal cancer: a dose-escalation pilot study.
    Boogerd LSF; Hoogstins CES; Schaap DP; Kusters M; Handgraaf HJM; van der Valk MJM; Hilling DE; Holman FA; Peeters KCMJ; Mieog JSD; van de Velde CJH; Farina-Sarasqueta A; van Lijnschoten I; Framery B; Pèlegrin A; Gutowski M; Nienhuijs SW; de Hingh IHJT; Nieuwenhuijzen GAP; Rutten HJT; Cailler F; Burggraaf J; Vahrmeijer AL
    Lancet Gastroenterol Hepatol; 2018 Mar; 3(3):181-191. PubMed ID: 29361435
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Factors influencing the pharmacokinetics, dosimetry, and diagnostic accuracy of radioimmunodetection and radioimmunotherapy of carcinoembryonic antigen-expressing tumors.
    Behr TM; Sharkey RM; Juweid MI; Dunn RM; Ying Z; Zhang CH; Siegel JA; Gold DV; Goldenberg DM
    Cancer Res; 1996 Apr; 56(8):1805-16. PubMed ID: 8620497
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Advantages of fluorescence-guided laparoscopic surgery of pancreatic cancer labeled with fluorescent anti-carcinoembryonic antigen antibodies in an orthotopic mouse model.
    Metildi CA; Kaushal S; Luiken GA; Hoffman RM; Bouvet M
    J Am Coll Surg; 2014 Jul; 219(1):132-41. PubMed ID: 24768506
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved antibody-guided surgery with a near-infrared dye on a pegylated linker for CEA-positive tumors.
    Yazaki P; Lwin T; Minnix M; Li L; Sherman A; Molnar J; Miller A; Frankel P; Chea J; Poku E; Bowles N; Hoffman R; Shively J; Bouvet M
    J Biomed Opt; 2019 Jun; 24(6):1-9. PubMed ID: 31254333
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Near-infrared-conjugated humanized anti-carcinoembryonic antigen antibody targets colon cancer in an orthotopic nude-mouse model.
    DeLong JC; Murakami T; Yazaki PJ; Hoffman RM; Bouvet M
    J Surg Res; 2017 Oct; 218():139-143. PubMed ID: 28985840
    [TBL] [Abstract][Full Text] [Related]  

  • 18. SPECT- and fluorescence image-guided surgery using a dual-labeled carcinoembryonic antigen-targeting antibody.
    Rijpkema M; Oyen WJ; Bos D; Franssen GM; Goldenberg DM; Boerman OC
    J Nucl Med; 2014 Sep; 55(9):1519-24. PubMed ID: 24982436
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An LED light source and novel fluorophore combinations improve fluorescence laparoscopic detection of metastatic pancreatic cancer in orthotopic mouse models.
    Metildi CA; Kaushal S; Lee C; Hardamon CR; Snyder CS; Luiken GA; Talamini MA; Hoffman RM; Bouvet M
    J Am Coll Surg; 2012 Jun; 214(6):997-1007.e2. PubMed ID: 22542065
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preclinical evaluation of a novel CEA-targeting near-infrared fluorescent tracer delineating colorectal and pancreatic tumors.
    Boonstra MC; Tolner B; Schaafsma BE; Boogerd LS; Prevoo HA; Bhavsar G; Kuppen PJ; Sier CF; Bonsing BA; Frangioni JV; van de Velde CJ; Chester KA; Vahrmeijer AL
    Int J Cancer; 2015 Oct; 137(8):1910-20. PubMed ID: 25895046
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.