These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

300 related articles for article (PubMed ID: 18666008)

  • 1. A new fluoroscopy-free navigation device for distal interlocking screw placement.
    Lee MY; Kuo CH; Hung SS
    J Med Eng Technol; 2008; 32(4):284-95. PubMed ID: 18666008
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Effects of medical robot-assisted surgical navigation system in distal locking of femoral intramedullary nails: an experimental study].
    Wang JQ; Wang JF; Hu L; Su YG; Wang Y; Zhao CP; Zhou L; Wang TM; Wang MY
    Zhonghua Yi Xue Za Zhi; 2006 Mar; 86(9):614-8. PubMed ID: 16681907
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Precise robot-assisted guide positioning for distal locking of intramedullary nails.
    Yaniv Z; Joskowicz L
    IEEE Trans Med Imaging; 2005 May; 24(5):624-35. PubMed ID: 15889550
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Sustentaculum tali screw placement for calcaneus fractures--different navigation procedures compared to the conventional technique].
    Gras F; Marintschev I; Wilharm A; Lindner R; Klos K; Mückley T; Hofmann GO
    Z Orthop Unfall; 2010 May; 148(3):309-18. PubMed ID: 20414866
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effectiveness of the external distal aiming device in intramedullary fixation of tibial shaft fractures.
    Babis GC; Benetos IS; Zoubos AB; Soucacos PN
    Arch Orthop Trauma Surg; 2007 Dec; 127(10):905-8. PubMed ID: 17641903
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature.
    Acosta FL; Thompson TL; Campbell S; Weinstein PR; Ames CP
    Spine J; 2005; 5(3):339-43. PubMed ID: 15863091
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hands-on robotic distal interlocking in intramedullary nail fixation of femoral shaft fractures.
    Oszwald M; Westphal R; Stier R; Gaulke R; Calafi A; Müller CW; Wahl F; Krettek C; Gösling T
    Technol Health Care; 2010; 18(4-5):325-34. PubMed ID: 21209481
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Percutaneous screw fixation in treatment of fractures of acetabular columns using computer-assisted imaging navigation system: experiment with cadaver model].
    Wang JQ; Wu E; Tang N; Zhao CP; Su YG; Wu XB; Wang MY; Leung KS
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(27):1900-4. PubMed ID: 19040003
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy of an aiming device for the placement of distal interlocking screws in trochanteric fixation nailing.
    Boraiah S; Barker JU; Lorich D
    Arch Orthop Trauma Surg; 2009 Sep; 129(9):1177-82. PubMed ID: 18677491
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.
    Windolf M; Schroeder J; Fliri L; Dicht B; Liebergall M; Richards RG
    BMC Musculoskelet Disord; 2012 Jan; 13():8. PubMed ID: 22276698
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Navigated pedicle screw placement: experimental comparison between CT- and 3D fluoroscopy-based techniques.
    Geerling J; Gösling T; Gösling A; Ortega G; Kendoff D; Citak M; Krettek C; Hüfner T
    Comput Aided Surg; 2008 May; 13(3):157-66. PubMed ID: 18432415
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Clinical contrast of cervical pedicle screw fixation assisted by C-arm fluoroscopy or 3D navigation system].
    Tian W; Liu YJ; Liu B; Li Q; Hu L; Li ZY; Yuan Q
    Zhonghua Wai Ke Za Zhi; 2006 Oct; 44(20):1399-402. PubMed ID: 17217832
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study.
    Suhm N; Messmer P; Zuna I; Jacob LA; Regazzoni P
    Injury; 2004 Jun; 35(6):567-74. PubMed ID: 15135275
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pedicle screw placement with O-arm and stealth navigation.
    Patil S; Lindley EM; Burger EL; Yoshihara H; Patel VV
    Orthopedics; 2012 Jan; 35(1):e61-5. PubMed ID: 22229616
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-dimensional augmented reality surgical navigation with hybrid optical and electromagnetic tracking for distal intramedullary nail interlocking.
    Ma L; Zhao Z; Zhang B; Jiang W; Fu L; Zhang X; Liao H
    Int J Med Robot; 2018 Aug; 14(4):e1909. PubMed ID: 29575601
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique.
    Ochs BG; Gonser C; Shiozawa T; Badke A; Weise K; Rolauffs B; Stuby FM
    Injury; 2010 Dec; 41(12):1297-305. PubMed ID: 20728881
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Peroneal nerve damage by oblique proximal locking screw in tibial fracture nailing: a new emerging complication?
    Drosos GI; Stavropoulos NI; Kazakos KI
    Arch Orthop Trauma Surg; 2007 Aug; 127(6):449-51. PubMed ID: 17124608
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures].
    Huang P; Tang PF; Yao Q; Liang YT; Tao S; Zhang Q; Guo YZ; Liang XD; Wang Y
    Zhongguo Gu Shang; 2008 Apr; 21(4):261-3. PubMed ID: 19102183
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Interlocking intramedullary nails. An improved method of screw placement combining image intensification and laser light.
    Goulet JA; Londy F; Saltzman CL; Matthews LS
    Clin Orthop Relat Res; 1992 Aug; (281):199-203. PubMed ID: 1499210
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.