These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 18667058)

  • 1. Tono-Pen XL tonometry during application of a suction ring in rabbits.
    Charisis SK; Ginis HS; Kounis GA; Tsilimbaris MK
    BMC Ophthalmol; 2008 Jul; 8():14. PubMed ID: 18667058
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tono-Pen versus Goldmann Applanation Tonometry: A Comparison of 898 Eyes.
    Bao B; Diaconita V; Schulz DC; Hutnik C
    Ophthalmol Glaucoma; 2019; 2(6):435-439. PubMed ID: 32672578
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions.
    Lee TE; Yoo C; Hwang JY; Lin S; Kim YY
    Curr Eye Res; 2015 Sep; 40(9):923-9. PubMed ID: 25271991
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology.
    von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A
    Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of intraocular pressure measurements between the Tono-Pen XL® and Perkins® applanation tonometers in dogs and cats.
    Andrade SF; Palozzi RJ; Giuffrida R; de Campos RJ; Santos Gde C; Fukui RM
    Vet Ophthalmol; 2012 Mar; 15 Suppl 1():14-20. PubMed ID: 22050624
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of the TonoVet® rebound tonometer in normal and glaucomatous cats.
    McLellan GJ; Kemmerling JP; Kiland JA
    Vet Ophthalmol; 2013 Mar; 16(2):111-8. PubMed ID: 22672669
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry.
    Badakere SV; Choudhari NS; Rao HL; Chary CR; Garudadri CS; Senthil S
    Optom Vis Sci; 2018 Feb; 95(2):129-135. PubMed ID: 29370020
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of two handheld applanation tonometers and the association of central corneal thickness, age, and intraocular pressure in normal and diseased canine eyes.
    Kato K
    Vet Ophthalmol; 2014 Nov; 17(6):417-25. PubMed ID: 24517734
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen.
    Ma D; Chen CB; Liang J; Lu Z; Chen H; Zhang M
    Sci Rep; 2016 Oct; 6():35187. PubMed ID: 27731381
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tono-Pen XL calibration curves for cats, cows and sheep.
    Passaglia CL; Guo X; Chen J; Troy JB
    Vet Ophthalmol; 2004; 7(4):261-4. PubMed ID: 15200622
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Agreement and reproducibility of Tono-Pen XL tip covered with ocufilm and fingertip of surgical glove in intra-ocular pressure measurement.
    Sayawat N; Duangnumsawang D
    J Med Assoc Thai; 2012 Apr; 95 Suppl 4():S102-6. PubMed ID: 22696861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model.
    Neuburger M; Maier P; Böhringer D; Reinhard T; F Jordan J
    J Glaucoma; 2013 Sep; 22(7):584-90. PubMed ID: 22366704
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tono-Pen, a new tonometer.
    Hessemer V; Rössler R; Jacobi KW
    Int Ophthalmol; 1989 Jan; 13(1-2):51-6. PubMed ID: 2663748
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of rabbit intraocular pressure with the Tono-Pen.
    Mermoud A; Baerveldt G; Minckler DS; Lee MB; Rao NA
    Ophthalmologica; 1995; 209(5):275-7. PubMed ID: 8570152
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
    Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D
    Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of central corneal thickness and radius of the corneal curvature on intraocular pressure measured with the Tono-Pen and noncontact tonometer in healthy schoolchildren.
    Yildirim N; Sahin A; Basmak H; Bal C
    J Pediatr Ophthalmol Strabismus; 2007; 44(4):216-22. PubMed ID: 17694826
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraocular pressure and photorefractive keratectomy: a comparison of three different tonometers.
    Garzozi HJ; Chung HS; Lang Y; Kagemann L; Harris A
    Cornea; 2001 Jan; 20(1):33-6. PubMed ID: 11189000
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intraoperative assessment of intraocular pressure in vitrectomized air-filled and fluid-filled eyes.
    Moon CH; Choi KS; Rhee MR; Lee SJ
    Acta Ophthalmol; 2013 Nov; 91(7):e524-8. PubMed ID: 23710577
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: an evaluation of the potential impact on clinical decision making in glaucoma.
    Carrim ZI; Lavy TE
    Ophthalmic Physiol Opt; 2009 Nov; 29(6):648-51. PubMed ID: 19821927
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraocular pressure measurement over amniotic membrane patch in human subjects.
    Hashizume A; Usui T; Yokoo S; Mimura T; Araie M; Yamagami S; Amano S
    Cornea; 2005 Nov; 24(8):925-7. PubMed ID: 16227834
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.