  • 1. Exposure to 50 Hz magnetic field in apartment buildings with built-in transformer stations in Hungary.
    Thuróczy G; Jánossy G; Nagy N; Bakos J; Szabó J; Mezei G
    Radiat Prot Dosimetry; 2008; 131(4):469-73. PubMed ID: 18667401
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Indoor transformer stations as predictors of residential ELF magnetic field exposure.
    Ilonen K; Markkanen A; Mezei G; Juutilainen J
    Bioelectromagnetics; 2008 Apr; 29(3):213-8. PubMed ID: 18044741
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Survey of residential 50 Hz EMF exposure from transformer stations.
    Szabó J; Jánossy G; Thuróczy G
    Bioelectromagnetics; 2007 Jan; 28(1):48-52. PubMed ID: 16988992
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Time dependence of 50 Hz magnetic fields in apartment buildings with indoor transformer stations.
    Yitzhak NM; Hareuveny R; Kandel S; Ruppin R
    Radiat Prot Dosimetry; 2012 Apr; 149(2):191-5. PubMed ID: 21632584
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Exposure to 50 Hz magnetic fields in apartment buildings with indoor transformer stations in Israel.
    Hareuveny R; Kandel S; Yitzhak NM; Kheifets L; Mezei G
    J Expo Sci Environ Epidemiol; 2011; 21(4):365-71. PubMed ID: 20407475
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Extremely low frequency magnetic field measurements in buildings with transformer stations in Switzerland.
    Röösli M; Jenni D; Kheifets L; Mezei G
    Sci Total Environ; 2011 Aug; 409(18):3364-9. PubMed ID: 21684576
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Apartment electrical wiring: a cause of extremely low frequency magnetic field exposure in residential areas.
    Moriyama K; Yoshitomi K
    Bioelectromagnetics; 2005 Apr; 26(3):238-41. PubMed ID: 15768426
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Magnetic field measurements near stand-alone transformer stations.
    Kandel S; Hareuveny R; Yitzhak NM; Ruppin R
    Radiat Prot Dosimetry; 2013 Dec; 157(4):619-22. PubMed ID: 23836796
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Registry of Buildings With Transformer Stations as a Basis for Epidemiological Studies on Health Effects of Extremely Low-Frequency Magnetic Fields.
    Khan MW; Juutilainen J; Roivainen P
    Bioelectromagnetics; 2020 Jan; 41(1):34-40. PubMed ID: 31742723
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does apartment's distance to an in-built transformer room predict magnetic field exposure levels?
    Huss A; Goris K; Vermeulen R; Kromhout H
    J Expo Sci Environ Epidemiol; 2013; 23(5):554-8. PubMed ID: 23340703
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Shielding of the geomagnetic field in apartment houses].
    Chernykh AM; Boriseĭko AN; Koval'chuk ML
    Gig Sanit; 2009; (5):69-71. PubMed ID: 20000094
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Indoor transformer stations and ELF magnetic field exposure: use of transformer structural characteristics to improve exposure assessment.
    Okokon EO; Roivainen P; Kheifets L; Mezei G; Juutilainen J
    J Expo Sci Environ Epidemiol; 2014; 24(1):100-4. PubMed ID: 24022671
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurements of ELF electromagnetic exposure of the general public from Belgian power distribution substations.
    Joseph W; Verloock L; Martens L
    Health Phys; 2008 Jan; 94(1):57-66. PubMed ID: 18091152
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radon in Finnish apartment buildings.
    Valmari T; Arvela H; Reisbacka H
    Radiat Prot Dosimetry; 2012 Nov; 152(1-3):146-9. PubMed ID: 22927660
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of the magnetic fields of high-voltage substations (230 kV) in Tehran (Iran) and comparison with the ACGIH threshold limit values.
    Fard MS; Nasiri P; Monazzam MR
    Radiat Prot Dosimetry; 2011 Jun; 145(4):421-5. PubMed ID: 21131660
    [TBL] [Abstract][Full Text] [Related]  

  • 16. International study of childhood leukemia in residences near electrical transformer rooms.
    Crespi CM; Sudan M; Juutilainen J; Roivainen P; Hareuveny R; Huss A; Kandel S; Karim-Kos HE; Thuróczy G; Jakab Z; Spycher BD; Flueckiger B; Vermeulen R; Vergara X; Kheifets L
    Environ Res; 2024 May; 249():118459. PubMed ID: 38346482
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of complex EMF exposure situations including inhomogeneous field distribution.
    Jokela K
    Health Phys; 2007 Jun; 92(6):531-40. PubMed ID: 17495653
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Importance of addressing National Electrical Code violations that result in unusual exposure to 60 Hz magnetic fields.
    Adams J; Samuel Bitler J; Riley K
    Bioelectromagnetics; 2004 Feb; 25(2):102-6. PubMed ID: 14735559
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Exposure assessment of ELF magnetic fields in urban environments in Extremadura (Spain).
    Paniagua JM; Jiménez A; Rufo M; Antolín A
    Bioelectromagnetics; 2004 Jan; 25(1):58-62. PubMed ID: 14696054
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Urban exposure to ELF magnetic field due to high-, medium- and low-voltage electricity supply networks.
    Bottura V; Cappio Borlino M; Carta N; Cerise L; Imperial E
    Radiat Prot Dosimetry; 2009 Dec; 137(3-4):214-7. PubMed ID: 19843546
    [TBL] [Abstract][Full Text] [Related]  