541 related articles for article (PubMed ID: 18672127)
21. Thermal changes in the pulp chamber during different adhesive clean-up procedures.
Uysal T; Eldeniz AU; Usumez S; Usumez A
Angle Orthod; 2005 Mar; 75(2):220-5. PubMed ID: 15825786
[TBL] [Abstract][Full Text] [Related]
22. Thermal effects on pulp due to laser and handpiece usage.
Penn C; Beninati C; Mariano A; Dooley D; Harsono M; Perry R; Kugel G
Compend Contin Educ Dent; 2014; 35(10):e41-4. PubMed ID: 25454819
[TBL] [Abstract][Full Text] [Related]
23. Pulpal temperature increases with Er:YAG laser and high-speed handpieces.
Cavalcanti BN; Lage-Marques JL; Rode SM
J Prosthet Dent; 2003 Nov; 90(5):447-51. PubMed ID: 14586308
[TBL] [Abstract][Full Text] [Related]
24. Temperature variation on root surface with three root-end cavity preparation techniques.
Bodrumlu E; Keskiner I; Sumer M; Telcioglu NT
Srp Arh Celok Lek; 2013; 141(9-10):597-601. PubMed ID: 24364220
[TBL] [Abstract][Full Text] [Related]
25. Handpiece coolant flow rates and dental cutting.
von Fraunhofer JA; Siegel SC; Feldman S
Oper Dent; 2000; 25(6):544-8. PubMed ID: 11203868
[TBL] [Abstract][Full Text] [Related]
26. Preparation for invasive pit and fissure sealing: air-abrasion or bur?
Kramer N; García-Godoy F; Lohbauer U; Schneider K; Assmann I; Frankenberger R
Am J Dent; 2008 Dec; 21(6):383-7. PubMed ID: 19146132
[TBL] [Abstract][Full Text] [Related]
27. Primary preparation of class II cavities with oscillating systems.
Wicht MJ; Haak R; Fritz UB; Noack MJ
Am J Dent; 2002 Feb; 15(1):21-5. PubMed ID: 12074224
[TBL] [Abstract][Full Text] [Related]
28. The magnitude of cutting forces at high speed.
Elias K; Amis AA; Setchell DJ
J Prosthet Dent; 2003 Mar; 89(3):286-91. PubMed ID: 12644805
[TBL] [Abstract][Full Text] [Related]
29. [2 burs compared: TDA and diamond].
Grazzini F; Baggi L
Attual Dent; 1987 Mar; 3(8):10-22. PubMed ID: 2820439
[No Abstract] [Full Text] [Related]
30. Principles of proximal cavity preparation and finishing with ultrasonic diamond tips.
Krejci I; Dietschi D; Lutz FU
Pract Periodontics Aesthet Dent; 1998 Apr; 10(3):295-8; quiz 300. PubMed ID: 9655063
[TBL] [Abstract][Full Text] [Related]
31. The use of CVD diamond burs for ultraconservative cavity preparations: a report of two cases.
Carvalho CA; Fagundes TC; Barata TJ; Trava-Airoldi VJ; Navarro MF
J Esthet Restor Dent; 2007; 19(1):19-28; discussion 29. PubMed ID: 17244145
[TBL] [Abstract][Full Text] [Related]
32. Cutting characteristics of dental diamond burs made with CVD technology.
Lima LM; Motisuki C; dos Santos-Pinto L; dos Santos-Pinto A; Corat EJ
Braz Oral Res; 2006; 20(2):155-61. PubMed ID: 16878210
[TBL] [Abstract][Full Text] [Related]
33. [Thermal response to ultra-high speed cutting in tooth structures].
Ulusoy N
Ankara Univ Hekim Fak Derg; 1985; 12(2):463-72. PubMed ID: 3915697
[No Abstract] [Full Text] [Related]
34. Temperature response in the pulpal chamber during ultrahigh-speed tooth preparation with diamond burs of different grit.
Ottl P; Lauer HC
J Prosthet Dent; 1998 Jul; 80(1):12-9. PubMed ID: 9656172
[TBL] [Abstract][Full Text] [Related]
35. [Evaluation of temperature variations in dental pulp during the use of rotary grinding instruments].
Rouit H
Chir Dent Fr; 1982 Jun; 52(161):43-6. PubMed ID: 6754283
[No Abstract] [Full Text] [Related]
36. Intrapulpal temperature during preparation with the Er:YAG laser compared to the conventional burr: an in vitro study.
Glockner K; Rumpler J; Ebeleseder K; Städtler P
J Clin Laser Med Surg; 1998 Jun; 16(3):153-7. PubMed ID: 9743653
[TBL] [Abstract][Full Text] [Related]
37. Direct measurement of time-dependent anesthetized in vivo human pulp temperature.
Runnacles P; Arrais CA; Pochapski MT; dos Santos FA; Coelho U; Gomes JC; De Goes MF; Gomes OM; Rueggeberg FA
Dent Mater; 2015 Jan; 31(1):53-9. PubMed ID: 25483936
[TBL] [Abstract][Full Text] [Related]
38. Effect of handpiece tip design on the cutting efficiency of an air abrasion system.
Santos-Pinto L; Peruchi C; Marker VA; Cordeiro R
Am J Dent; 2001 Dec; 14(6):397-401. PubMed ID: 11949801
[TBL] [Abstract][Full Text] [Related]
39. Heat transfer to the implant-bone interface during preparation of a zirconia/alumina abutment.
Huh JB; Eckert SE; Ko SM; Choi YG
Int J Oral Maxillofac Implants; 2009; 24(4):679-83. PubMed ID: 19885408
[TBL] [Abstract][Full Text] [Related]
40. [Cutting efficiency of diamond burs].
Lasagni D; Graziani E; Marchionni A; Morsiani D
Attual Dent; 1988 Apr; 4(13-14):34-9. PubMed ID: 2855023
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]