BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 18674721)

  • 1. Clinical evaluation of iterative reconstruction (ordered-subset expectation maximization) in dynamic positron emission tomography: quantitative effects on kinetic modeling with N-13 ammonia in healthy subjects.
    Hove JD; Rasmussen R; Freiberg J; Holm S; Kelbaek H; Kofoed KE
    J Nucl Cardiol; 2008; 15(4):530-4. PubMed ID: 18674721
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of image reconstruction algorithm on neurotransmission PET studies in humans: comparison between filtered backprojection and ordered subsets expectation maximization.
    Morimoto T; Ito H; Takano A; Ikoma Y; Seki C; Okauchi T; Tanimoto K; Ando A; Shiraishi T; Yamaya T; Suhara T
    Ann Nucl Med; 2006 Apr; 20(3):237-43. PubMed ID: 16715957
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET.
    Søndergaard HM; Madsen MM; Boisen K; Bøttcher M; Schmitz O; Nielsen TT; Bøtker HE; Hansen SB
    Eur J Nucl Med Mol Imaging; 2007 Mar; 34(3):320-9. PubMed ID: 17033850
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET.
    Chen GP; Branch KR; Alessio AM; Pham P; Tabibiazar R; Kinahan P; Caldwell JH
    J Nucl Med; 2007 Aug; 48(8):1259-65. PubMed ID: 17631543
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals.
    Cheng JC; Shoghi K; Laforest R
    Med Phys; 2012 Feb; 39(2):1029-41. PubMed ID: 22320813
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Image reconstruction using filtered backprojection and iterative method: effect on motion artifacts in myocardial perfusion SPECT.
    Zakavi SR; Zonoozi A; Kakhki VD; Hajizadeh M; Momennezhad M; Ariana K
    J Nucl Med Technol; 2006 Dec; 34(4):220-3. PubMed ID: 17146110
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Preliminary evaluation of image reconstruction by ordered-subset expectation maximization in thallium-201 lung scintigraphy.
    Bai J; Yokoyama K; Kinuya S; Nakajima K; Yamada M; Ichiyanagi K; Michigishi T; Tonami N
    Ann Nucl Med; 2003 Oct; 17(7):619-24. PubMed ID: 14651366
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling.
    Boellaard R; van Lingen A; Lammertsma AA
    J Nucl Med; 2001 May; 42(5):808-17. PubMed ID: 11337581
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Bayesian-penalized likelihood reconstruction on [13N]-NH3 rest perfusion quantification.
    O' Doherty J; McGowan DR; Abreu C; Barrington S
    J Nucl Cardiol; 2017 Feb; 24(1):282-290. PubMed ID: 27435278
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of time-of-flight on qualitative and quantitative analyses of myocardial perfusion PET studies using (13)N-ammonia.
    Tomiyama T; Ishihara K; Suda M; Kanaya K; Sakurai M; Takahashi N; Takano H; Nitta K; Hakozaki K; Kumita S
    J Nucl Cardiol; 2015 Oct; 22(5):998-1007. PubMed ID: 25467250
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.
    DePuey EG; Gadiraju R; Clark J; Thompson L; Anstett F; Shwartz SC
    J Nucl Cardiol; 2008; 15(4):547-63. PubMed ID: 18674723
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT.
    Brambilla M; Cannillo B; Dominietto M; Leva L; Secco C; Inglese E
    Ann Nucl Med; 2005 Apr; 19(2):75-82. PubMed ID: 15909485
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison among Reconstruction Algorithms for Quantitative Analysis of
    Shi X; Li N; Ding H; Dang Y; Hu G; Liu S; Cui J; Zhang Y; Li F; Zhang H; Huo L
    Contrast Media Mol Imaging; 2018; 2018():9193403. PubMed ID: 29681784
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Appropriate parameters of the ordered-subset expectation maximization algorithm on measurement of myocardial blood flow and oxygen consumption with 11C-acetate PET.
    Kobayashi M; Mori T; Kiyono Y; Tsujikawa T; Maruyama R; Higaki Y; Shikano N; Nishii R; Kawai K; Kudo T; Okazawa H
    Nucl Med Commun; 2012 Feb; 33(2):130-8. PubMed ID: 22124363
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET.
    Schepis T; Gaemperli O; Treyer V; Valenta I; Burger C; Koepfli P; Namdar M; Adachi I; Alkadhi H; Kaufmann PA
    J Nucl Med; 2007 Nov; 48(11):1783-9. PubMed ID: 17942816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Postinjection transmission scanning in myocardial 18F-FDG PET studies using both filtered backprojection and iterative reconstruction.
    van der Weerdt AP; Boellaard R; Knaapen P; Visser CA; Lammertsma AA; Visser FC
    J Nucl Med; 2004 Feb; 45(2):169-75. PubMed ID: 14960632
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of image reconstruction algorithms in myocardial perfusion scintigraphy.
    Bai J; Hashimoto J; Suzuki T; Nakahara T; Kubo A; Iwanaga S; Mitamura H; Ogawa S
    Ann Nucl Med; 2001 Feb; 15(1):79-83. PubMed ID: 11355789
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Is iterative reconstruction an alternative to filtered backprojection in routine processing of dopamine transporter SPECT studies?
    Koch W; Hamann C; Welsch J; Pöpperl G; Radau PE; Tatsch K
    J Nucl Med; 2005 Nov; 46(11):1804-11. PubMed ID: 16269593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pediatric 99mTc-DMSA SPECT performed by using iterative reconstruction with isotropic resolution recovery: improved image quality and reduced radiopharmaceutical activity.
    Sheehy N; Tetrault TA; Zurakowski D; Vija AH; Fahey FH; Treves ST
    Radiology; 2009 May; 251(2):511-6. PubMed ID: 19304919
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Left atrial versus left ventricular input function for quantification of the myocardial blood flow with nitrogen-13 ammonia and positron emission tomography.
    Hove JD; Iida H; Kofoed KF; Freiberg J; Holm S; Kelbaek H
    Eur J Nucl Med Mol Imaging; 2004 Jan; 31(1):71-6. PubMed ID: 14551750
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.