685 related articles for article (PubMed ID: 18681285)
21. Optimal graft diameter: effect of wall shear stress on vascular healing.
Binns RL; Ku DN; Stewart MT; Ansley JP; Coyle KA
J Vasc Surg; 1989 Sep; 10(3):326-37. PubMed ID: 2778897
[TBL] [Abstract][Full Text] [Related]
22. The effect of carbon coating and porosity on early patency of expanded polytetrafluoroethylene grafts: an experimental study.
Akers DL; Du YH; Kempczinski RF
J Vasc Surg; 1993 Jul; 18(1):10-5. PubMed ID: 8326650
[TBL] [Abstract][Full Text] [Related]
23. Coaxial double-tubular compliant arterial graft prosthesis: time-dependent morphogenesis and compliance changes after implantation.
Sonoda H; Takamizawa K; Nakayama Y; Yasui H; Matsuda T
J Biomed Mater Res A; 2003 May; 65(2):170-81. PubMed ID: 12734809
[TBL] [Abstract][Full Text] [Related]
24. In vivo evaluation of biomimetic fluorosurfactant polymer-coated expanded polytetrafluoroethylene vascular grafts in a porcine carotid artery bypass model.
Bastijanic JM; Marchant RE; Kligman F; Allemang MT; Lakin RO; Kendrick D; Kashyap VS; Kottke-Marchant K
J Vasc Surg; 2016 Jun; 63(6):1620-1630.e4. PubMed ID: 25827964
[TBL] [Abstract][Full Text] [Related]
25. Tissue-engineered blood vessel graft produced by self-derived cells and allogenic acellular matrix: a functional performance and histologic study.
Yang D; Guo T; Nie C; Morris SF
Ann Plast Surg; 2009 Mar; 62(3):297-303. PubMed ID: 19240529
[TBL] [Abstract][Full Text] [Related]
26. Hydrophilic microporous polyurethane versus expanded PTFE grafts as substitutes in the carotid arteries of dogs. A limited study.
Martz H; Paynter R; Ben Slimane S; Beaudoin G; Guidoin R; Borzone J; Ben Simhon H; Satin R; Sheiner N
J Biomed Mater Res; 1988 Jan; 22(1):63-9. PubMed ID: 3343258
[TBL] [Abstract][Full Text] [Related]
27. Quantitative evaluation of ibuprofen treatment on thrombogenicity of expanded polytetrafluoroethylene vascular grafts.
Gloviczki P; Hollier LH; Dewanjee MK; Trastek VF; Kopesky KR; Kaye MP
Surgery; 1984 Feb; 95(2):160-8. PubMed ID: 6695334
[TBL] [Abstract][Full Text] [Related]
28. Efficacy of collagen silver-coated polyester and rifampin-soaked vascular grafts to resist infection from MRSA and Escherichia coli in a dog model.
Schneider F; O'Connor S; Becquemin JP
Ann Vasc Surg; 2008 Nov; 22(6):815-21. PubMed ID: 18835516
[TBL] [Abstract][Full Text] [Related]
29. Comparison of tissue reaction with three different endografts used for exclusion of carotid artery aneurysm in a dog model.
Zhu YQ; Cheng YS; Li MH; Zhang HX; Zhao JG; Wang YL
J Vasc Interv Radiol; 2009 Jun; 20(6):791-8. PubMed ID: 19318281
[TBL] [Abstract][Full Text] [Related]
30. [Compliance of small diameter polyurethane artificial vascular graft ].
Pan S; Tao J; Zheng H; Yi W
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Jun; 23(3):517-20. PubMed ID: 16856381
[TBL] [Abstract][Full Text] [Related]
31. Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis.
Mrówczyński W; Mugnai D; de Valence S; Tille JC; Khabiri E; Cikirikcioglu M; Möller M; Walpoth BH
J Vasc Surg; 2014 Jan; 59(1):210-9. PubMed ID: 23707057
[TBL] [Abstract][Full Text] [Related]
32. [Influence of human tissue factor pathway inhibitor gene transfection on neointima formation in vein grafts].
Li Q; Zhang K; Jiang X; Sun T; Wu L; Zhou C; Chen S
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Mar; 22(3):354-8. PubMed ID: 18396721
[TBL] [Abstract][Full Text] [Related]
33. Matching the diameter of ePTFE bypass prosthesis with a native artery improves neoendothelialization.
Cikirikcioglu M; Pektok E; Cikirikcioglu YB; Osorio-da Cruz S; Tille JC; Kalangos A; Walpoth BH
Eur Surg Res; 2008; 40(4):333-40. PubMed ID: 18303269
[TBL] [Abstract][Full Text] [Related]
34. [Study on patency of small caliber synthetic vascular prosthesis--with special reference to antithrombogenesity of fibrin layer].
Nishibe T
Hokkaido Igaku Zasshi; 1991 Nov; 66(6):758-67. PubMed ID: 1783366
[TBL] [Abstract][Full Text] [Related]
35. Small-caliber polyurethane and polytetrafluoroethylene grafts: a comparative study in a canine aortoiliac model.
Brothers TE; Stanley JC; Burkel WE; Graham LM
J Biomed Mater Res; 1990 Jun; 24(6):761-71. PubMed ID: 2361967
[TBL] [Abstract][Full Text] [Related]
36. Novel bioengineered small caliber vascular graft with excellent one-month patency.
Ishii Y; Kronengold RT; Virmani R; Rivera EA; Goldman SM; Prechtel EJ; Schuessler RB; Damiano RJ
Ann Thorac Surg; 2007 Feb; 83(2):517-25. PubMed ID: 17257981
[TBL] [Abstract][Full Text] [Related]
37. High-dose preoperative fractionated radiotherapy does not affect the patency and healing of ePTFE vascular prosthesis after replacement of canine abdominal aorta and inferior vena cava.
Guo Y; Shu C; Zhou X; Jiang X; Li Q
Eur J Vasc Endovasc Surg; 2012 Apr; 43(4):460-5. PubMed ID: 22261487
[TBL] [Abstract][Full Text] [Related]
38. Experimental studies on application of small-caliber vascular prosthesis produced by polyurethane.
Miyamoto K; Sugimoto T; Okada M; Maeda S
Ann Thorac Cardiovasc Surg; 1999 Jun; 5(3):174-81. PubMed ID: 10413764
[TBL] [Abstract][Full Text] [Related]
39. Short-term patency of 1 mm diameter PTFE prosthesis: an angiographic, Doppler-flowmetric and morphological experimental study.
Durante CM; Camboni A; Bianchi S; Macchiarelli G
Ital J Anat Embryol; 2005; 110(2 Suppl 1):117-25. PubMed ID: 16101029
[TBL] [Abstract][Full Text] [Related]
40. Microvascular endothelial cell sodding of ePTFE vascular grafts: improved patency and stability of the cellular lining.
Williams SK; Rose DG; Jarrell BE
J Biomed Mater Res; 1994 Feb; 28(2):203-12. PubMed ID: 8207032
[TBL] [Abstract][Full Text] [Related]