98 related articles for article (PubMed ID: 18687844)
1. A report on the early failure of the LPM proximal interphalangeal joint replacement.
Hobby JL; Edwards S; Field J; Giddins G;
J Hand Surg Eur Vol; 2008 Aug; 33(4):526-7. PubMed ID: 18687844
[TBL] [Abstract][Full Text] [Related]
2. Two to five year follow-up of the LPM ceramic coated proximal interphalangeal joint arthroplasty.
Field J
J Hand Surg Eur Vol; 2008 Feb; 33(1):38-44. PubMed ID: 18332018
[TBL] [Abstract][Full Text] [Related]
3. Failures of the RM finger prosthesis joint replacement system.
Middleton A; Lakshmipathy R; Irwin LR
J Hand Surg Eur Vol; 2011 Sep; 36(7):599-604. PubMed ID: 21593065
[TBL] [Abstract][Full Text] [Related]
4. Re: the LPM Titanium semi-constrained proximal interphalangeal joint replacement.
Giddins G; Hobby J
J Hand Surg Br; 2006 Apr; 31(2):246. PubMed ID: 16426713
[No Abstract] [Full Text] [Related]
5. [Early results of proximal interphalangeal joint replacement with pyrolytic carbon prosthesis (Ascension) in idiopathic and post-traumatic arthritis].
Schulz M; Müller-Zimmermann A; Behrend M; Krimmer H
Handchir Mikrochir Plast Chir; 2005 Feb; 37(1):26-34. PubMed ID: 15744654
[TBL] [Abstract][Full Text] [Related]
6. Surface replacement arthroplasty of the proximal interphalangeal joint using the PIP-SRA implant: results, complications, and revisions.
Jennings CD; Livingstone DP
J Hand Surg Am; 2008 Nov; 33(9):1565.e1-11. PubMed ID: 18984339
[TBL] [Abstract][Full Text] [Related]
7. Prosthetic replacement of the proximal interphalangeal joint.
Murray PM
Hand Clin; 2006 May; 22(2):201-6. PubMed ID: 16701133
[TBL] [Abstract][Full Text] [Related]
8. A conservative approach for proximal interphalangeal joint arthroplasty.
Fahmy NR; Lavender A; Brew C
J Hand Surg Br; 2001 Jun; 26(3):235-7. PubMed ID: 11386774
[TBL] [Abstract][Full Text] [Related]
9. Analysis of failed Van Straten LPM proximal interphalangeal prostheses.
Bone MC; Cunningham JL; Lord J; Giddins G; Field J; Joyce TJ
J Hand Surg Eur Vol; 2013 Mar; 38(3):313-20. PubMed ID: 22989733
[TBL] [Abstract][Full Text] [Related]
10. [Post-acute management of fractures of the proximal interphalangeal joint with metal prosthesis: first experience].
Larcher S; Espen D
Handchir Mikrochir Plast Chir; 2007 Aug; 39(4):263-6. PubMed ID: 17724647
[TBL] [Abstract][Full Text] [Related]
11. High loosening rate of the Moje Acamo prosthesis for treating osteoarthritis of the trapeziometacarpal joint.
Hansen TB; Vainorius D
J Hand Surg Eur Vol; 2008 Oct; 33(5):571-4. PubMed ID: 18694921
[TBL] [Abstract][Full Text] [Related]
12. [Characterization of the biological process of aseptic loosening of joint implants in orthopedics].
Fuchs D; Zinman C; Lewinson D
Harefuah; 1998 Mar; 134(6):432-5, 504, 503. PubMed ID: 10909569
[TBL] [Abstract][Full Text] [Related]
13. Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up.
Gallo J; Landor I; Cechová I; Jahoda D
Acta Chir Orthop Traumatol Cech; 2008 Oct; 75(5):339-46. PubMed ID: 19026187
[TBL] [Abstract][Full Text] [Related]
14. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.
Zwartelé RE; Olsthoorn PG; Pöll RG; Brand R; Doets HC
Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793
[TBL] [Abstract][Full Text] [Related]
15. [Long-term clinical result of posterior cruciate ligament retaining total knee arthroplasty: 15 years follow-up study].
Guo L; Yang L; Briard JL
Zhonghua Wai Ke Za Zhi; 2008 Dec; 46(23):1804-7. PubMed ID: 19094792
[TBL] [Abstract][Full Text] [Related]
16. [Total lumbar disc replacement with SB Charité III prosthesis: Chinese experience with more than two years follow-up].
Lu SB; Wang QY; Hai Y; Su QJ; Kang N; Zhang CS
Zhonghua Wai Ke Za Zhi; 2008 Mar; 46(5):342-5. PubMed ID: 18785528
[TBL] [Abstract][Full Text] [Related]
17. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].
Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A
Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277
[TBL] [Abstract][Full Text] [Related]
18. Reverse shoulder arthroplasty: does reduced medialisation improve radiological and clinical results?
Kalouche I; Sevivas N; Wahegaonker A; Sauzieres P; Katz D; Valenti P
Acta Orthop Belg; 2009 Apr; 75(2):158-66. PubMed ID: 19492554
[TBL] [Abstract][Full Text] [Related]
19. [Mechanisms, prevention, and treatments of prosthetic aseptic loosening].
Wei J; Cai X; Wang Y; Chen H; Zhang B
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Mar; 24(3):296-300. PubMed ID: 20369528
[TBL] [Abstract][Full Text] [Related]
20. Biocompatibility of total joint replacements: A review.
Goodman SB; Gómez Barrena E; Takagi M; Konttinen YT
J Biomed Mater Res A; 2009 Aug; 90(2):603-18. PubMed ID: 18508337
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]