BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 18690900)

  • 1. Evaluating clinical accuracy of continuous glucose monitoring systems: Continuous Glucose-Error Grid Analysis (CG-EGA).
    Clarke WL; Anderson S; Kovatchev B
    Curr Diabetes Rev; 2008 Aug; 4(3):193-9. PubMed ID: 18690900
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data.
    Kovatchev BP; Gonder-Frederick LA; Cox DJ; Clarke WL
    Diabetes Care; 2004 Aug; 27(8):1922-8. PubMed ID: 15277418
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.
    Clarke WL; Anderson S; Farhy L; Breton M; Gonder-Frederick L; Cox D; Kovatchev B
    Diabetes Care; 2005 Oct; 28(10):2412-7. PubMed ID: 16186272
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A critical appraisal of the continuous glucose-error grid analysis.
    Wentholt IM; Hoekstra JB; Devries JH
    Diabetes Care; 2006 Aug; 29(8):1805-11. PubMed ID: 16873784
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of blood glucose predictors: the prediction-error grid analysis.
    Sivananthan S; Naumova V; Man CD; Facchinetti A; Renard E; Cobelli C; Pereverzyev SV
    Diabetes Technol Ther; 2011 Aug; 13(8):787-96. PubMed ID: 21612393
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy.
    Clarke WL; Kovatchev B
    J Diabetes Sci Technol; 2007 Sep; 1(5):669-75. PubMed ID: 19885134
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of the numerical and clinical accuracy of four continuous glucose monitors.
    Kovatchev B; Anderson S; Heinemann L; Clarke W
    Diabetes Care; 2008 Jun; 31(6):1160-4. PubMed ID: 18339974
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Glucose Prediction Algorithms from Continuous Monitoring Data: Assessment of Accuracy via Continuous Glucose Error-Grid Analysis.
    Zanderigo F; Sparacino G; Kovatchev B; Cobelli C
    J Diabetes Sci Technol; 2007 Sep; 1(5):645-51. PubMed ID: 19718282
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluating clinical accuracy of continuous glucose monitoring devices: other methods.
    Wentholt IM; Hart AA; Hoekstra JB; DeVries JH
    Curr Diabetes Rev; 2008 Aug; 4(3):200-6. PubMed ID: 18690901
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of a novel noninvasive transdermal continuous glucose monitor in critically ill patients.
    Saur NM; England MR; Menzie W; Melanson AM; Trieu MQ; Berlin J; Hurley J; Krystyniak K; Kongable GL; Nasraway SA
    J Diabetes Sci Technol; 2014 Sep; 8(5):945-50. PubMed ID: 24876448
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical assessment and mathematical modeling of the accuracy of continuous glucose sensors (CGS).
    Kovatchev BP; King C; Breton M; Anderson S; Clarke W
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():71-4. PubMed ID: 17945569
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Metabolic/glycemic control accuracy, effect and complications of the continuous glucose monitoring system in diabetic patients].
    Maia FF; Araújo LR
    Rev Assoc Med Bras (1992); 2006; 52(6):395-400. PubMed ID: 17242774
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia.
    Gómez AM; Marín Sánchez A; Muñoz OM; Colón Peña CA
    Endocrinol Nutr; 2015 Dec; 62(10):485-92. PubMed ID: 26531841
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimation of future glucose concentrations with subject-specific recursive linear models.
    Eren-Oruklu M; Cinar A; Quinn L; Smith D
    Diabetes Technol Ther; 2009 Apr; 11(4):243-53. PubMed ID: 19344199
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Limitations of statistical measures of error in assessing the accuracy of continuous glucose sensors.
    Kollman C; Wilson DM; Wysocki T; Tamborlane WV; Beck RW;
    Diabetes Technol Ther; 2005 Oct; 7(5):665-72; discussion 673-4. PubMed ID: 16241865
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?
    Mazze RS; Strock E; Borgman S; Wesley D; Stout P; Racchini J
    Diabetes Technol Ther; 2009 Jan; 11(1):11-8. PubMed ID: 19132850
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of time point of calibration on accuracy of continuous glucose monitoring in individuals with type 1 diabetes.
    Zueger T; Diem P; Mougiakakou S; Stettler C
    Diabetes Technol Ther; 2012 Jul; 14(7):583-8. PubMed ID: 22512266
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.
    Joseph JI; Torjman MC; Strasma PJ
    J Diabetes Sci Technol; 2015 Jul; 9(4):725-38. PubMed ID: 26078254
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluating clinical accuracy of systems for self-monitoring of blood glucose.
    Clarke WL; Cox D; Gonder-Frederick LA; Carter W; Pohl SL
    Diabetes Care; 1987; 10(5):622-8. PubMed ID: 3677983
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Standardization versus customization of glucose reporting.
    Rodbard D
    Diabetes Technol Ther; 2013 May; 15(5):439-43. PubMed ID: 23634672
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.