BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

223 related articles for article (PubMed ID: 18691802)

  • 1. Variation in inspiratory time and tidal volume with T-piece neonatal resuscitator: association with operator experience and distraction.
    McHale S; Thomas M; Hayden E; Bergin K; McCallion N; Molloy EJ
    Resuscitation; 2008 Nov; 79(2):230-3. PubMed ID: 18691802
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of three neonatal resuscitation devices.
    Bennett S; Finer NN; Rich W; Vaucher Y
    Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Leak during manual neonatal ventilation and its effect on the delivered pressures and volumes: an in vitro study.
    Hartung JC; te Pas AB; Fischer H; Schmalisch G; Roehr CC
    Neonatology; 2012; 102(3):190-5. PubMed ID: 22796898
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Manual ventilation devices in neonatal resuscitation: tidal volume and positive pressure-provision.
    Roehr CC; Kelm M; Fischer HS; Bührer C; Schmalisch G; Proquitté H
    Resuscitation; 2010 Feb; 81(2):202-5. PubMed ID: 19926383
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.
    Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C
    Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of methods of bag and mask ventilation for neonatal resuscitation.
    Finer NN; Rich W; Craft A; Henderson C
    Resuscitation; 2001 Jun; 49(3):299-305. PubMed ID: 11719125
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neopuff T-piece resuscitator: does device design affect delivered ventilation?
    Hinder M; Jani P; Priyadarshi A; McEwan A; Tracy M
    Arch Dis Child Fetal Neonatal Ed; 2017 May; 102(3):F220-F224. PubMed ID: 27645491
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.
    O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F392-6. PubMed ID: 15871989
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Providing PEEP during neonatal resuscitation: which device is best?
    Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
    J Paediatr Child Health; 2011 Oct; 47(10):698-703. PubMed ID: 21449898
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Equipment and operator training denote manual ventilation performance in neonatal resuscitation.
    Roehr CC; Kelm M; Proquitté H; Schmalisch G
    Am J Perinatol; 2010 Oct; 27(9):753-8. PubMed ID: 20458664
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Changing gas flow during neonatal resuscitation: a manikin study.
    Schilleman K; Schmölzer GM; Kamlin OC; Morley CJ; te Pas AB; Davis PG
    Resuscitation; 2011 Jul; 82(7):920-4. PubMed ID: 21444142
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The mouth-to-bag resuscitator during standard anaesthesia induction in apnoeic patients.
    Herff H; Paal P; Mitterlechner T; von Goedecke A; Stadlbauer KH; Voelckel WG; Zecha-Stallinger A; Wenzel V
    Resuscitation; 2009 Oct; 80(10):1142-6. PubMed ID: 19674827
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sustained inflations: comparing three neonatal resuscitation devices.
    Klingenberg C; Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
    Neonatology; 2011; 100(1):78-84. PubMed ID: 21273792
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Unintentional variation in positive end expiratory pressure during resuscitation with a T-piece resuscitator.
    Finer NN; Rich WD
    Resuscitation; 2011 Jun; 82(6):717-9. PubMed ID: 21481520
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Potential hazard of the Neopuff T-piece resuscitator in the absence of flow limitation.
    Hawkes CP; Oni OA; Dempsey EM; Ryan CA
    Arch Dis Child Fetal Neonatal Ed; 2009 Nov; 94(6):F461-3. PubMed ID: 19357121
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Responding to compliance changes in a lung model during manual ventilation: perhaps volume, rather than pressure, should be displayed.
    Kattwinkel J; Stewart C; Walsh B; Gurka M; Paget-Brown A
    Pediatrics; 2009 Mar; 123(3):e465-70. PubMed ID: 19188267
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ventilator-delivered mask ventilation compared with three standard methods of mask ventilation in a manikin model.
    Tracy MB; Klimek J; Coughtrey H; Shingde V; Ponnampalam G; Hinder M; Maheshwari R; Tracy SK
    Arch Dis Child Fetal Neonatal Ed; 2011 May; 96(3):F201-5. PubMed ID: 20530107
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An evaluation of peak inspiratory pressure, tidal volume, and ventilatory frequency during ventilation with a neonatal self-inflating bag resuscitator.
    Bassani MA; Filho FM; de Carvalho Coppo MR; Martins Marba ST
    Respir Care; 2012 Apr; 57(4):525-30. PubMed ID: 22005778
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Can Ambu self-inflating bag and Neopuff infant resuscitator provide adequate and safe manual inflations for infants up to 10 kg weight?
    Tracy M; Maheshwari R; Shah D; Hinder M
    Arch Dis Child Fetal Neonatal Ed; 2017 Jul; 102(4):F333-F338. PubMed ID: 28011794
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.