These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 18693507)
21. Processing of pulse oximeter data using discrete wavelet analysis. Lee S; Ibey BL; Xu W; Wilson MA; Ericson MN; Coté GL IEEE Trans Biomed Eng; 2005 Jul; 52(7):1350-2. PubMed ID: 16042000 [TBL] [Abstract][Full Text] [Related]
22. Independent component analysis applied to pulse oximetry in the estimation of the arterial oxygen saturation (SpO2)--a comparative study. Jensen T; Duun S; Larsen J; Haahr RG; Toft MH; Belhage B; Thomsen EV Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():4039-44. PubMed ID: 19964339 [TBL] [Abstract][Full Text] [Related]
23. Particle Filtering and Sensor Fusion for Robust Heart Rate Monitoring Using Wearable Sensors. Nathan V; Jafari R IEEE J Biomed Health Inform; 2018 Nov; 22(6):1834-1846. PubMed ID: 29990023 [TBL] [Abstract][Full Text] [Related]
24. Technical note: Evaluation of a wireless pulse oximeter for measuring arterial oxygen saturation and pulse rate in newborn Holstein Friesian calves. Kanz P; Krieger S; Drillich M; Iwersen M J Dairy Sci; 2018 Jul; 101(7):6437-6442. PubMed ID: 29705429 [TBL] [Abstract][Full Text] [Related]
25. Study of Artifact-Resistive Technology Based on a Novel Dual Photoplethysmography Method for Wearable Pulse Rate Monitors. Zhou C; Feng J; Hu J; Ye X J Med Syst; 2016 Mar; 40(3):56. PubMed ID: 26645320 [TBL] [Abstract][Full Text] [Related]
26. Improving pulse oximetry accuracy by removing motion artifacts from photoplethysmograms using relative sensor motion: a preliminary study. Wijshoff RWCGR; Mischi M; Woerlee PH; Aarts RM Adv Exp Med Biol; 2013; 789():411-417. PubMed ID: 23852523 [TBL] [Abstract][Full Text] [Related]
27. Cardiac gating with a pulse oximeter for dual-energy imaging. Shkumat NA; Siewerdsen JH; Dhanantwari AC; Williams DB; Paul NS; Yorkston J; Van Metter R Phys Med Biol; 2008 Nov; 53(21):6097-112. PubMed ID: 18854611 [TBL] [Abstract][Full Text] [Related]
28. A computer algorithm for differentiating valid from distorted pulse oximeter waveforms in neonates. Adams JA; Inman IM; Abreu SA; Zabaleta IA; Sackner MA Pediatr Pulmonol; 1995 May; 19(5):307-11. PubMed ID: 7567206 [TBL] [Abstract][Full Text] [Related]
29. Motion based adaptive calibration of pulse transit time measurements to arterial blood pressure for an autonomous, wearable blood pressure monitor. McCombie DB; Reisner AT; Asada HH Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():989-92. PubMed ID: 19162824 [TBL] [Abstract][Full Text] [Related]
30. A novel algorithm to separate motion artifacts from photoplethysmographic signals obtained with a reflectance pulse oximeter. Yao J; Warren S Conf Proc IEEE Eng Med Biol Soc; 2004; 2004():2153-6. PubMed ID: 17272150 [TBL] [Abstract][Full Text] [Related]
31. Effects of motion on the performance of pulse oximeters in volunteers. Barker SJ; Shah NK Anesthesiology; 1996 Oct; 85(4):774-81. PubMed ID: 8873547 [TBL] [Abstract][Full Text] [Related]
32. Detection of movement artifact in recorded pulse oximeter saturation. Poets CF; Stebbens VA Eur J Pediatr; 1997 Oct; 156(10):808-11. PubMed ID: 9365075 [TBL] [Abstract][Full Text] [Related]
33. Incremental diagnosis method for intelligent wearable sensor systems. Wu WH; Bui AA; Batalin MA; Liu D; Kaiser WJ IEEE Trans Inf Technol Biomed; 2007 Sep; 11(5):553-62. PubMed ID: 17912972 [TBL] [Abstract][Full Text] [Related]
34. A new method for pulse oximetry possessing inherent insensitivity to artifact. Hayes MJ; Smith PR IEEE Trans Biomed Eng; 2001 Apr; 48(4):452-61. PubMed ID: 11322533 [TBL] [Abstract][Full Text] [Related]
35. Evaluation of pulse oximetry in anaesthetised foals using multiple combinations of transducer type and transducer attachment site. Chaffin MK; Matthews NS; Cohen ND; Carter GK Equine Vet J; 1996 Nov; 28(6):437-45. PubMed ID: 9049492 [TBL] [Abstract][Full Text] [Related]
36. Ambulatory oximetry monitoring in patients with severe COPD: a preliminary study. Pilling J; Cutaia M Chest; 1999 Aug; 116(2):314-21. PubMed ID: 10453857 [TBL] [Abstract][Full Text] [Related]
37. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph. Warren KM; Harvey JR; Chon KH; Mendelson Y Sensors (Basel); 2016 Mar; 16(3):. PubMed ID: 26959034 [TBL] [Abstract][Full Text] [Related]
38. Utility of approximate entropy from overnight pulse oximetry data in the diagnosis of the obstructive sleep apnea syndrome. Hornero R; Alvarez D; Abásolo D; del Campo F; Zamarrón C IEEE Trans Biomed Eng; 2007 Jan; 54(1):107-13. PubMed ID: 17260861 [TBL] [Abstract][Full Text] [Related]
39. Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity. Jarchi D; Casson AJ IEEE Trans Biomed Eng; 2017 Sep; 64(9):2042-2053. PubMed ID: 28212075 [TBL] [Abstract][Full Text] [Related]
40. A motion-tolerant approach for monitoring SpO Fan F; Yan Y; Tang Y; Zhang H Comput Biol Med; 2017 Dec; 91():291-305. PubMed ID: 29102826 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]