BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

296 related articles for article (PubMed ID: 18693760)

  • 1. A peptide-based, ratiometric biosensor construct for direct fluorescence detection of a protein analyte.
    Enander K; Choulier L; Olsson AL; Yushchenko DA; Kanmert D; Klymchenko AS; Demchenko AP; Mély Y; Altschuh D
    Bioconjug Chem; 2008 Sep; 19(9):1864-70. PubMed ID: 18693760
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A peptide-based fluorescent ratiometric sensor for quantitative detection of proteins.
    Choulier L; Shvadchak VV; Naidoo A; Klymchenko AS; Mély Y; Altschuh D
    Anal Biochem; 2010 Jun; 401(2):188-95. PubMed ID: 20188691
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved hydration-sensitive dual-fluorescence labels for monitoring peptide-nucleic acid interactions.
    Zamotaiev OM; Postupalenko VY; Shvadchak VV; Pivovarenko VG; Klymchenko AS; Mély Y
    Bioconjug Chem; 2011 Jan; 22(1):101-7. PubMed ID: 21174445
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A ratiometric fluorescent viscosity sensor.
    Haidekker MA; Brady TP; Lichlyter D; Theodorakis EA
    J Am Chem Soc; 2006 Jan; 128(2):398-9. PubMed ID: 16402812
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design of a hybrid biosensor for enhanced phosphopeptide recognition based on a phosphoprotein binding domain coupled with a fluorescent chemosensor.
    Anai T; Nakata E; Koshi Y; Ojida A; Hamachi I
    J Am Chem Soc; 2007 May; 129(19):6232-9. PubMed ID: 17441721
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improving the sensitivity and dynamic range of reagentless fluorescent immunosensors by knowledge-based design.
    Renard M; Bedouelle H
    Biochemistry; 2004 Dec; 43(49):15453-62. PubMed ID: 15581357
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Construction of ratiometric fluorescent sensors by ribonucleopeptides.
    Annoni C; Nakata E; Tamura T; Liew FF; Nakano S; Gelmi ML; Morii T
    Org Biomol Chem; 2012 Nov; 10(44):8767-9. PubMed ID: 23069733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Semisynthetic fluorescent sensor proteins based on self-labeling protein tags.
    Brun MA; Tan KT; Nakata E; Hinner MJ; Johnsson K
    J Am Chem Soc; 2009 Apr; 131(16):5873-84. PubMed ID: 19348459
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel two-fluorophore approach to ratiometric sensing of Zn(2+).
    Woodroofe CC; Lippard SJ
    J Am Chem Soc; 2003 Sep; 125(38):11458-9. PubMed ID: 13129323
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dual labeling of a binding protein allows for specific fluorescence detection of native protein.
    Karlström A; Nygren PA
    Anal Biochem; 2001 Aug; 295(1):22-30. PubMed ID: 11476541
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo targeting of organic calcium sensors via genetically selected peptides.
    Marks KM; Rosinov M; Nolan GP
    Chem Biol; 2004 Mar; 11(3):347-56. PubMed ID: 15123264
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design and construction of glutamine binding proteins with a self-adhering capability to unmodified hydrophobic surfaces as reagentless fluorescence sensing devices.
    Wada A; Mie M; Aizawa M; Lahoud P; Cass AE; Kobatake E
    J Am Chem Soc; 2003 Dec; 125(52):16228-34. PubMed ID: 14692764
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Synthesis of novel bispyrene diamines and their application as ratiometric fluorescent probes for detection of DNA.
    Yang Y; Ji S; Zhou F; Zhao J
    Biosens Bioelectron; 2009 Aug; 24(12):3442-7. PubMed ID: 19497731
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A ratiometric fluorescent probe for hypochlorite based on a deoximation reaction.
    Lin W; Long L; Chen B; Tan W
    Chemistry; 2009; 15(10):2305-9. PubMed ID: 19156808
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Selection and characterization of Affibody ligands to the transcription factor c-Jun.
    Lundberg E; Brismar H; Gräslund T
    Biotechnol Appl Biochem; 2009 Jan; 52(Pt 1):17-27. PubMed ID: 18260830
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ratiometric fluorescence detection of a tag fused protein using the dual-emission artificial molecular probe.
    Honda K; Nakata E; Ojida A; Hamachi I
    Chem Commun (Camb); 2006 Oct; (38):4024-6. PubMed ID: 17003887
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fluorescent probe based on intramolecular proton transfer for fast ratiometric measurement of cellular transmembrane potential.
    Klymchenko AS; Stoeckel H; Takeda K; Mély Y
    J Phys Chem B; 2006 Jul; 110(27):13624-32. PubMed ID: 16821890
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Concentration measurement of unpurified proteins using biosensor technology under conditions of partial mass transport limitation.
    Richalet-Sécordel PM; Rauffer-Bruyère N; Christensen LL; Ofenloch-Haehnle B; Seidel C; Van Regenmortel MH
    Anal Biochem; 1997 Jul; 249(2):165-73. PubMed ID: 9212868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Synthesis and use of an in-solution ratiometric fluorescent viscosity sensor.
    Fischer D; Theodorakis EA; Haidekker MA
    Nat Protoc; 2007; 2(1):227-36. PubMed ID: 17401358
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Local environment perturbations in alpha1-antitrypsin monitored by a ratiometric fluorescent label.
    Boudier C; Klymchenko AS; Mely Y; Follenius-Wund A
    Photochem Photobiol Sci; 2009 Jun; 8(6):814-21. PubMed ID: 19492109
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.