These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
147 related articles for article (PubMed ID: 18697703)
21. Linking a neural mass model with a 3D model of the human brain to reproduce EEG signals. Petersen S; Zimmermann U; Schmidt C; Schwabe L; Warkentin M; Teipel SJ Biomed Tech (Berl); 2014 Jun; 59(3):231-40. PubMed ID: 24515994 [TBL] [Abstract][Full Text] [Related]
22. Influence of skull anisotropy for the forward and inverse problem in EEG: simulation studies using FEM on realistic head models. Marin G; Guerin C; Baillet S; Garnero L; Meunier G Hum Brain Mapp; 1998; 6(4):250-69. PubMed ID: 9704264 [TBL] [Abstract][Full Text] [Related]
24. Effects of uncertainty in head tissue conductivity and complexity on EEG forward modeling in neonates. Azizollahi H; Aarabi A; Wallois F Hum Brain Mapp; 2016 Oct; 37(10):3604-22. PubMed ID: 27238749 [TBL] [Abstract][Full Text] [Related]
25. Forward and inverse problems of EEG dipole localization. Musha T; Okamoto Y Crit Rev Biomed Eng; 1999; 27(3-5):189-239. PubMed ID: 10864280 [TBL] [Abstract][Full Text] [Related]
26. Influence of white matter conductivity anisotropy on electric field strength induced by electroconvulsive therapy. Lee WH; Deng ZD; Laine AF; Lisanby SH; Peterchev AV Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():5473-6. PubMed ID: 22255576 [TBL] [Abstract][Full Text] [Related]
27. Three-layer-isotropic skull conductivity representation in the EEG forward problem using spherical head models. Cuartas-Morales E; Hallez H; Vanrumste B; Castellanos-Dominguez G Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():4904-7. PubMed ID: 25571091 [TBL] [Abstract][Full Text] [Related]
28. A finite-element reciprocity solution for EEG forward modeling with realistic individual head models. Ziegler E; Chellappa SL; Gaggioni G; Ly JQM; Vandewalle G; André E; Geuzaine C; Phillips C Neuroimage; 2014 Dec; 103():542-551. PubMed ID: 25204867 [TBL] [Abstract][Full Text] [Related]
29. A FDM anisotropic formulation for EEG simulation. Bruno P; Hyttinen J; Inchingolo P; Magrofuoco A; Mininel S; Vatta F Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1121-5. PubMed ID: 17946024 [TBL] [Abstract][Full Text] [Related]
30. Neonatal EEG at scalp is focal and implies high skull conductivity in realistic neonatal head models. Odabaee M; Tokariev A; Layeghy S; Mesbah M; Colditz PB; Ramon C; Vanhatalo S Neuroimage; 2014 Aug; 96():73-80. PubMed ID: 24736169 [TBL] [Abstract][Full Text] [Related]
31. The value and cost of complexity in predictive modelling: role of tissue anisotropic conductivity and fibre tracts in neuromodulation. Shahid SS; Bikson M; Salman H; Wen P; Ahfock T J Neural Eng; 2014 Jun; 11(3):036002. PubMed ID: 24737098 [TBL] [Abstract][Full Text] [Related]
32. Computational modeling of human head electromagnetics for source localization of milliscale brain dynamics. Malony AD; Salman A; Turovets S; Tucker D; Volkov V; Li K; Song JE; Biersdorff S; Davey C; Hoge C; Hammond D Stud Health Technol Inform; 2011; 163():329-35. PubMed ID: 21335813 [TBL] [Abstract][Full Text] [Related]
33. [Modeling the effect of the layer thickness and tissue conductivities of the head and the brain on the EEG potentials using finite element method]. Stavtsev AIu; Ushakov VL; Verkhliutov VM Zh Vyssh Nerv Deiat Im I P Pavlova; 2007; 57(6):742-52. PubMed ID: 18592709 [TBL] [Abstract][Full Text] [Related]
34. Representation of bioelectric current sources using Whitney elements in the finite element method. Tanzer IO; Järvenpää S; Nenonen J; Somersalo E Phys Med Biol; 2005 Jul; 50(13):3023-39. PubMed ID: 15972978 [TBL] [Abstract][Full Text] [Related]
35. Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull. Ryynänen OR; Hyttinen JA; Malmivuo JA IEEE Trans Biomed Eng; 2006 Sep; 53(9):1851-8. PubMed ID: 16941841 [TBL] [Abstract][Full Text] [Related]
36. The effect of tissue anisotropy on the EEG inverse problem. Cook MJ; Koles ZJ Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():4563-6. PubMed ID: 19163731 [TBL] [Abstract][Full Text] [Related]
37. 3-D diffusion tensor MRI anisotropy content-adaptive finite element head model generation for bioelectromagnetic imaging. Lee WH; Kim TS; Kim AT; Lee SY Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():4003-6. PubMed ID: 19163590 [TBL] [Abstract][Full Text] [Related]
38. Brainstorm-DUNEuro: An integrated and user-friendly Finite Element Method for modeling electromagnetic brain activity. Medani T; Garcia-Prieto J; Tadel F; Antonakakis M; Erdbrügger T; Höltershinken M; Mead W; Schrader S; Joshi A; Engwer C; Wolters CH; Mosher JC; Leahy RM Neuroimage; 2023 Feb; 267():119851. PubMed ID: 36599389 [TBL] [Abstract][Full Text] [Related]
39. A global sensitivity analysis of three- and four-layer EEG conductivity models. Vallaghé S; Clerc M IEEE Trans Biomed Eng; 2009 Apr; 56(4):988-95. PubMed ID: 19272874 [TBL] [Abstract][Full Text] [Related]
40. Effects of geometric head model perturbations on the EEG forward and inverse problems. von Ellenrieder N; Muravchik CH; Nehorai A IEEE Trans Biomed Eng; 2006 Mar; 53(3):421-9. PubMed ID: 16532768 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]