These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 18699043)

  • 1. New hydrostatic pressure cell to 90 kilobars for precise electrical and magnetic measurements at low temperatures.
    Fasol G; Schilling JS
    Rev Sci Instrum; 1978 Dec; 49(12):1722. PubMed ID: 18699043
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hall measurements to 40 kilobars under hydrostatic pressure in a piston-cylinder device.
    Lifshitz N; Maines RG
    Rev Sci Instrum; 1979 May; 50(5):608. PubMed ID: 18699560
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Miniature diamond anvil cell for broad range of high pressure measurements.
    Gavriliuk AG; Mironovich AA; Struzhkin VV
    Rev Sci Instrum; 2009 Apr; 80(4):043906. PubMed ID: 19405674
    [TBL] [Abstract][Full Text] [Related]  

  • 4. System for ESR measurements at hydrostatic pressures to 60 kilobars.
    Barnett JD; Tyagi SD; Nelson HM
    Rev Sci Instrum; 1978 Mar; 49(3):348. PubMed ID: 18699095
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Four-probe electrical measurements with a liquid pressure medium in a diamond anvil cell.
    Jaramillo R; Feng Y; Rosenbaum TF
    Rev Sci Instrum; 2012 Oct; 83(10):103902. PubMed ID: 23126777
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High pressure cell for Raman scattering at low temperatures.
    Jodl HJ; Holzapfel WB
    Rev Sci Instrum; 1979 Mar; 50(3):340. PubMed ID: 18699504
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hydrostatic optical cell with simple window structure for low temperature and hydrostatic pressure up to 5 kilobars.
    Yamada M; Schmidt VH
    Rev Sci Instrum; 1978 Aug; 49(8):1226. PubMed ID: 18699294
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noncontact technique for measuring the electrical resistivity and magnetic susceptibility of electrostatically levitated materials.
    Rustan GE; Spyrison NS; Kreyssig A; Prozorov R; Goldman AI
    Rev Sci Instrum; 2012 Oct; 83(10):103907. PubMed ID: 23126782
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Precise measurements of radial temperature gradients in the laser-heated diamond anvil cell.
    Kavner A; Nugent C
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):024902. PubMed ID: 18315322
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anomalous criticality in the electrical resistivity of La2-xSrxCuO4.
    Cooper RA; Wang Y; Vignolle B; Lipscombe OJ; Hayden SM; Tanabe Y; Adachi T; Koike Y; Nohara M; Takagi H; Proust C; Hussey NE
    Science; 2009 Jan; 323(5914):603-7. PubMed ID: 19074310
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of pressure cell for specific heat measurement at low temperature and high Magnetic field.
    Kawae T; Yaita K; Yoshida Y; Inagaki Y; Ohashi M; Oomi G; Matsubayashi K; Matsumoto T; Uwatoko Y
    Rev Sci Instrum; 2009 Feb; 80(2):025102. PubMed ID: 19256673
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 90-kilobar diamond-anvil high-pressure cell for use on an automatic diffractometer.
    Schiferl D; Jamieson JC; Lenko JE
    Rev Sci Instrum; 1978 Mar; 49(3):359. PubMed ID: 18699097
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-resolution thermal expansion measurements under helium-gas pressure.
    Manna RS; Wolf B; de Souza M; Lang M
    Rev Sci Instrum; 2012 Aug; 83(8):085111. PubMed ID: 22938336
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nonmagnetic high pressure cell for magnetic remanence measurements up to 1.5 GPa in a superconducting quantum interference device magnetometer.
    Sadykov RA; Bezaeva NS; Kharkovskiy AI; Rochette P; Gattacceca J; Trukhin VI
    Rev Sci Instrum; 2008 Nov; 79(11):115102. PubMed ID: 19045908
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Zeolite Molecular Sieve 4A: Anomalous Compressibility and Volume Discontinuities at High Pressure.
    Hazen RM
    Science; 1983 Mar; 219(4588):1065-7. PubMed ID: 17811746
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A high-precision apparatus for the characterization of thermal interface materials.
    Kempers R; Kolodner P; Lyons A; Robinson AJ
    Rev Sci Instrum; 2009 Sep; 80(9):095111. PubMed ID: 19791968
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Steel pressure vessels for hydrostatic pressures to 50 kilobars.
    Lavergne A; Whalley E
    Rev Sci Instrum; 1978 Jul; 49(7):923. PubMed ID: 18699223
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A high temperature cell for simultaneous electrical resistance and neutron diffraction measurements.
    Engin TE; Powell AV; Haynes R; Chowdhury MA; Goodway CM; Done R; Kirichek O; Hull S
    Rev Sci Instrum; 2008 Sep; 79(9):095104. PubMed ID: 19044451
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Resistivity and thermopower measurement setups in the temperature range of 5-325 K.
    Soni A; Okram GS
    Rev Sci Instrum; 2008 Dec; 79(12):125103. PubMed ID: 19123588
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrical properties of new organic conductor (BEST)(2)InBr(4) [BEST = bis(ethylenediseleno)tetrathiafulvalene] up to 10.8 GPa and antiferromagnetic transition of (BEST)(2)FeBr(4).
    Cui H; Brooks J; Graf D; Okano Y; Sun H; Kobayashi H
    Inorg Chem; 2009 May; 48(10):4268-70. PubMed ID: 19323462
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.