These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 18699190)

  • 1. Adaption of a diamond anvil cell to an automatic four-circle diffractometer for x-ray diffraction.
    Denner W; Dieterich W; Schulz H; Keller R; Holzapfel WB
    Rev Sci Instrum; 1978 Jun; 49(6):775. PubMed ID: 18699190
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 90-kilobar diamond-anvil high-pressure cell for use on an automatic diffractometer.
    Schiferl D; Jamieson JC; Lenko JE
    Rev Sci Instrum; 1978 Mar; 49(3):359. PubMed ID: 18699097
    [TBL] [Abstract][Full Text] [Related]  

  • 3. System for ESR measurements at hydrostatic pressures to 60 kilobars.
    Barnett JD; Tyagi SD; Nelson HM
    Rev Sci Instrum; 1978 Mar; 49(3):348. PubMed ID: 18699095
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Properties of diamond under hydrostatic pressures up to 140 GPa.
    Occelli F; Loubeyre P; LeToullec R
    Nat Mater; 2003 Mar; 2(3):151-4. PubMed ID: 12612670
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-intensity x-ray diffraction apparatus for pressures up to 100 kilobars and temperatures down to 1.5 K.
    Thorwarth E; Dietrich M
    Rev Sci Instrum; 1979 Jun; 50(6):768. PubMed ID: 18699601
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-Pressure Single-Crystal Studies of Ice VI.
    Block S; Weir CW; Piermarini GJ
    Science; 1965 May; 148(3672):947-8. PubMed ID: 17751043
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A perforated diamond anvil cell for high-energy x-ray diffraction of liquids and amorphous solids at high pressure.
    Soignard E; Benmore CJ; Yarger JL
    Rev Sci Instrum; 2010 Mar; 81(3):035110. PubMed ID: 20370216
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Density measurements of noncrystalline materials at high pressure with diamond anvil cell.
    Hong X; Shen G; Prakapenka VB; Rivers ML; Sutton SR
    Rev Sci Instrum; 2007 Oct; 78(10):103905. PubMed ID: 17979433
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-pressure-low-temperature x-ray power diffractometer.
    Syassen K; Holzapfel WB
    Rev Sci Instrum; 1978 Aug; 49(8):1107. PubMed ID: 18699263
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pressure study of monoclinic ReO2 up to 1.2 GPa using X-ray absorption spectroscopy and X-ray diffraction.
    Ferreira FF; Corrêa HP; Orlando MT; Passamai JL; Orlando CG; Cavalcante IP; Garcia F; Tamura E; Martinez LG; Rossi JL; de Melo FC
    J Synchrotron Radiat; 2009 Jan; 16(Pt 1):48-56. PubMed ID: 19096174
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In situ laser heating and radial synchrotron x-ray diffraction in a diamond anvil cell.
    Kunz M; Caldwell WA; Miyagi L; Wenk HR
    Rev Sci Instrum; 2007 Jun; 78(6):063907. PubMed ID: 17614626
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A combination of a Drickamer anvil apparatus and monochromatic X-rays for stress and strain measurements under high pressure.
    Nishiyama N; Wang Y; Irifune T; Sanehira T; Rivers ML; Sutton SR; Cookson D
    J Synchrotron Radiat; 2009 Nov; 16(Pt 6):742-7. PubMed ID: 19844008
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The structural variation of rhombohedral LaAlO3 perovskite under non-hydrostatic stress fields in a diamond-anvil cell.
    Zhao J; Angel RJ; Ross NL
    J Phys Condens Matter; 2011 May; 23(17):175901. PubMed ID: 21493973
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Studying single nanocrystals under high pressure using an x-ray nanoprobe.
    Wang L; Ding Y; Patel U; Yang W; Xiao Z; Cai Z; Mao WL; Mao HK
    Rev Sci Instrum; 2011 Apr; 82(4):043903. PubMed ID: 21529021
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Strategies for reducing preferred orientation and strain in powder samples for high-pressure synchrotron X-ray diffraction in diamond-anvil cells.
    Tschauner O; McClure J; Nicol M
    J Synchrotron Radiat; 2005 Sep; 12(Pt 5):626-31. PubMed ID: 16120986
    [TBL] [Abstract][Full Text] [Related]  

  • 16. BX90: a new diamond anvil cell design for X-ray diffraction and optical measurements.
    Kantor I; Prakapenka V; Kantor A; Dera P; Kurnosov A; Sinogeikin S; Dubrovinskaia N; Dubrovinsky L
    Rev Sci Instrum; 2012 Dec; 83(12):125102. PubMed ID: 23278021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Uniform stress conditions in the diamond anvil cell at 200 kilobars.
    Besson JM; Pinceaux JP
    Rev Sci Instrum; 1979 May; 50(5):541. PubMed ID: 18699548
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microfabrication of controlled-geometry samples for the laser-heated diamond-anvil cell using focused ion beam technology.
    Pigott JS; Reaman DM; Panero WR
    Rev Sci Instrum; 2011 Nov; 82(11):115106. PubMed ID: 22129012
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A simple external resistance heating diamond anvil cell and its application for synchrotron radiation x-ray diffraction.
    Fan D; Zhou W; Wei S; Liu Y; Ma M; Xie H
    Rev Sci Instrum; 2010 May; 81(5):053903. PubMed ID: 20515151
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Single-crystal synchrotron X-ray diffraction study of wüstite and magnesiowüstite at lower-mantle pressures.
    Jacobsen SD; Lin JF; Angel RJ; Shen G; Prakapenka VB; Dera P; Mao HK; Hemley RJ
    J Synchrotron Radiat; 2005 Sep; 12(Pt 5):577-83. PubMed ID: 16120980
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.