These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 18699585)

  • 1. Cold-stage microscopy system for fast-frozen liquids.
    Talmon Y; Davis HT; Scriven LE; Thomas EL
    Rev Sci Instrum; 1979 Jun; 50(6):698. PubMed ID: 18699585
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dynamic hydration effects in an electron microscope cold stage.
    Lamvik MK; Davilla SD
    J Electron Microsc Tech; 1988 Apr; 8(4):349-54. PubMed ID: 3199218
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of TEM specimen preparation of perovskite thin films by tripod polishing and conventional ion milling.
    Eberg E; Monsen AF; Tybell T; van Helvoort AT; Holmestad R
    J Electron Microsc (Tokyo); 2008 Dec; 57(6):175-9. PubMed ID: 18815212
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A simple pneumatic device for plunge-freezing cells grown on electron microscopy grids.
    Cole R; Matuszek G; See C; Rieder CL
    J Electron Microsc Tech; 1990 Oct; 16(2):167-73. PubMed ID: 2213239
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Self-pressurized rapid freezing (SPRF): a novel cryofixation method for specimen preparation in electron microscopy.
    Leunissen JL; Yi H
    J Microsc; 2009 Jul; 235(1):25-35. PubMed ID: 19566624
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Slow-speed freezing of chemically unfixed biological tissues and long-term storage of frozen samples for cryoscanning electron microscopy.
    Adler K; Kruse J; Kunze G
    Microsc Res Tech; 1996 Feb; 33(3):262-5. PubMed ID: 8652884
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Facile deposition of nanodimensional ceria particles and their assembly into conformal films at liquid-liquid interface with a phase transfer catalyst.
    Mlondo SN; Thomas PJ; O'Brien P
    J Am Chem Soc; 2009 May; 131(17):6072-3. PubMed ID: 19361159
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of liquid nitrogen and liquid helium as cryogens for electron cryotomography.
    Iancu CV; Wright ER; Heymann JB; Jensen GJ
    J Struct Biol; 2006 Mar; 153(3):231-40. PubMed ID: 16427786
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Smart specimen preparation for freeze substitution and serial ultrathin sectioning of yeast cells.
    Yamaguchi M; Okada H; Namiki Y
    J Electron Microsc (Tokyo); 2009 Aug; 58(4):261-6. PubMed ID: 19289851
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preparation of combinatorial arrays of polymer thin films for transmission electron microscopy analysis.
    Roskov KE; Epps TH; Berry BC; Hudson SD; Tureau MS; Fasolka MJ
    J Comb Chem; 2008; 10(6):966-73. PubMed ID: 18937515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Freeze-fracture electron microscopy.
    Severs NJ
    Nat Protoc; 2007; 2(3):547-76. PubMed ID: 17406618
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Beam damage suppression of low-kappa porous Si-O-C films by cryo-electron-energy loss spectroscopy (EELS).
    Otsuka Y; Shimizu Y; Tanaka I
    J Electron Microsc (Tokyo); 2009 Apr; 58(2):29-34. PubMed ID: 19218485
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In situ deformation of thin films on substrates.
    Legros M; CabiƩ M; Gianola DS
    Microsc Res Tech; 2009 Mar; 72(3):270-83. PubMed ID: 19189313
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improvement of windowed type environmental-cell transmission electron microscope for in situ observation of gas-solid interactions.
    Kawasaki T; Ueda K; Ichihashi M; Tanji T
    Rev Sci Instrum; 2009 Nov; 80(11):113701. PubMed ID: 19947731
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In situ observation of the melting and sintering of submicron-sized bismuth particles.
    Diewald S; Feldmann C
    Nanotechnology; 2009 Mar; 20(12):125704. PubMed ID: 19420481
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Crystallographic analysis of thin specimens.
    Sivel VG; Tichelaar FD; Mohdadi H; Alkemade PF; Zandbergen HW
    J Microsc; 2005 May; 218(Pt 2):115-24. PubMed ID: 15857373
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High resolution cryo system designed for JEM 100CX electron microscope.
    Jeng TW; Chiu W
    Ultramicroscopy; 1987; 23(1):61-6. PubMed ID: 3660492
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Formation of barium strontium titanate thin films via electrophoretic deposition process.
    Wang HW; Cheng PC; Liang CF; Chang YS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Dec; 55(12):2539-43. PubMed ID: 19126478
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A device for retrieving electron microscope grids on formvar films from liquid surfaces.
    Hatch MH
    Stain Technol; 1968 May; 43(3):177-8. PubMed ID: 5656754
    [No Abstract]   [Full Text] [Related]  

  • 20. Validation of convection-limited cooling of samples for freeze-fracture electron microscopy.
    Bailey SM; Zasadzinski JA
    J Microsc; 1991 Sep; 163(Pt 3):307-20. PubMed ID: 1960713
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.