These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 18699874)

  • 1. Frova introducer: neither a stylet nor simply an introducer.
    Sorbello M; Frova G
    Anaesthesia; 2008 Sep; 63(9):1010-1; author reply 1011-3. PubMed ID: 18699874
    [No Abstract]   [Full Text] [Related]  

  • 2. Evaluation of clinical effectiveness of the Frova single-use tracheal tube introducer.
    Hodzovic I; Wilkes AR; Stacey M; Latto IP
    Anaesthesia; 2008 Feb; 63(2):189-94. PubMed ID: 18211451
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer.
    Hodzovic I; Latto IP; Wilkes AR; Hall JE; Mapleson WW
    Anaesthesia; 2004 Aug; 59(8):811-6. PubMed ID: 15270974
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of tracheal tube introducers in simulated difficult intubation.
    Janakiraman C; Hodzovic I; Reddy S; Desai N; Wilkes AR; Latto IP
    Anaesthesia; 2009 Mar; 64(3):309-14. PubMed ID: 19302646
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Frova introducer for tracheal intubation - our comments and experience.
    Umesh G; Jasvinder K
    Anaesthesia; 2008 Nov; 63(11):1260-1; author reply 1261-2. PubMed ID: 19032267
    [No Abstract]   [Full Text] [Related]  

  • 6. Retraction movement of the Frova airway intubation introducer to assist nasotracheal intubation in patients with limited mouth opening.
    Schoettker P; Bathory I; Broome M
    Anesthesiology; 2010 Dec; 113(6):1476-8. PubMed ID: 20980911
    [No Abstract]   [Full Text] [Related]  

  • 7. Retrograde intubation using a frova intubating introducer in a patient with a tracheostomy.
    Kim SH; Choi YS; Oh YJ
    Anesth Analg; 2012 Jul; 115(1):209-10. PubMed ID: 22723210
    [No Abstract]   [Full Text] [Related]  

  • 8. [Role of the long stylet in difficult intubations].
    Frova G
    Rev Med Suisse Romande; 1999 Nov; 119(11):903-6. PubMed ID: 10628212
    [No Abstract]   [Full Text] [Related]  

  • 9. Shearing of a Frova Intubating Introducer by a Bronchocath double lumen tube.
    Vlachtsis H; Veltman M
    Anaesthesia; 2006 Feb; 61(2):197-8; discussion 198-9. PubMed ID: 16430585
    [No Abstract]   [Full Text] [Related]  

  • 10. The Flex-It stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope.
    Turkstra TP; Jones PM; Ower KM; Gros ML
    Anesth Analg; 2009 Dec; 109(6):1856-9. PubMed ID: 19923515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of lighted stylet (Surch-Lite) and direct laryngoscopic intubation in patients with high Mallampati scores.
    Rhee KY; Lee JR; Kim J; Park S; Kwon WK; Han S
    Anesth Analg; 2009 Apr; 108(4):1215-9. PubMed ID: 19299790
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The Eschman introducer for difficult tracheal intubation].
    Villalonga J; Santacoloma B; Villalonga G; Martínez Alday J
    Rev Esp Anestesiol Reanim; 1996; 43(7):265-6. PubMed ID: 8966361
    [No Abstract]   [Full Text] [Related]  

  • 13. Hazards associated with the use of a disposable reinforced tracheal tube.
    Ismail S; Khan FA
    J Coll Physicians Surg Pak; 2005 Mar; 15(3):189-90. PubMed ID: 15808108
    [No Abstract]   [Full Text] [Related]  

  • 14. Can the Shikani Optical Stylet facilitate intubation in simulated difficult direct laryngoscopy?
    Young CF; Vadivelu N
    Conn Med; 2007 Aug; 71(7):407-8. PubMed ID: 17879863
    [No Abstract]   [Full Text] [Related]  

  • 15. Airtraq for awake tracheal intubation.
    Suzuki A; Toyama Y; Iwasaki H; Henderson J
    Anaesthesia; 2007 Jul; 62(7):746-7. PubMed ID: 17567358
    [No Abstract]   [Full Text] [Related]  

  • 16. Unexpected difficult intubation with Portex tracheal tube introducer.
    Zwall JW; Gupta S
    Anaesthesia; 2003 Feb; 58(2):187; discussion 187. PubMed ID: 12562420
    [No Abstract]   [Full Text] [Related]  

  • 17. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients.
    Maassen R; Lee R; Hermans B; Marcus M; van Zundert A
    Anesth Analg; 2009 Nov; 109(5):1560-5. PubMed ID: 19713258
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The endotracheal tube introducer revisited.
    Knopp RK
    Ann Emerg Med; 2000 Jul; 36(1):74-5. PubMed ID: 10874243
    [No Abstract]   [Full Text] [Related]  

  • 19. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
    van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
    Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Videolaryngoscopy--making intubation more successful.
    Van Zundert AA; Maassen RL; Hermans B; Lee RA
    Acta Anaesthesiol Belg; 2008; 59(3):177-8. PubMed ID: 19051449
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.