548 related articles for article (PubMed ID: 18701771)
1. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.
Sidky EY; Pan X
Phys Med Biol; 2008 Sep; 53(17):4777-807. PubMed ID: 18701771
[TBL] [Abstract][Full Text] [Related]
2. Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.
Niu T; Zhu L
Med Phys; 2012 Jul; 39(7):4588-98. PubMed ID: 22830790
[TBL] [Abstract][Full Text] [Related]
3. Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR).
Shieh CC; Kipritidis J; O'Brien RT; Cooper BJ; Kuncic Z; Keall PJ
Phys Med Biol; 2015 Jan; 60(2):841-68. PubMed ID: 25565244
[TBL] [Abstract][Full Text] [Related]
4. Simultaneous deblurring and iterative reconstruction of CBCT for image guided brain radiosurgery.
Hashemi S; Song WY; Sahgal A; Lee Y; Huynh C; Grouza V; Nordström H; Eriksson M; Dorenlot A; Régis JM; Mainprize JG; Ruschin M
Phys Med Biol; 2017 Apr; 62(7):2521-2541. PubMed ID: 28248652
[TBL] [Abstract][Full Text] [Related]
5. Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.
Tseng HW; Vedantham S; Karellas A
Phys Med; 2020 May; 73():117-124. PubMed ID: 32361156
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT.
Matenine D; Mascolo-Fortin J; Goussard Y; Després P
Med Phys; 2015 Nov; 42(11):6376-86. PubMed ID: 26520729
[TBL] [Abstract][Full Text] [Related]
7. Image quality in thoracic 4D cone-beam CT: a sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing.
Shieh CC; Kipritidis J; O'Brien RT; Kuncic Z; Keall PJ
Med Phys; 2014 Apr; 41(4):041912. PubMed ID: 24694143
[TBL] [Abstract][Full Text] [Related]
8. A TV-minimization image-reconstruction algorithm without system matrix.
Qiao Z; Lu Y
J Xray Sci Technol; 2021; 29(5):851-865. PubMed ID: 34308898
[TBL] [Abstract][Full Text] [Related]
9. Sparse-view proton computed tomography using modulated proton beams.
Lee J; Kim C; Min B; Kwak J; Park S; Lee SB; Park S; Cho S
Med Phys; 2015 Feb; 42(2):1129-37. PubMed ID: 25652524
[TBL] [Abstract][Full Text] [Related]
10. A simple and fast ASD-POCS algorithm for image reconstruction.
Qiao Z
J Xray Sci Technol; 2021; 29(3):491-506. PubMed ID: 33843721
[TBL] [Abstract][Full Text] [Related]
11. GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation.
Jia X; Lou Y; Li R; Song WY; Jiang SB
Med Phys; 2010 Apr; 37(4):1757-60. PubMed ID: 20443497
[TBL] [Abstract][Full Text] [Related]
12. GPU-accelerated regularized iterative reconstruction for few-view cone beam CT.
Matenine D; Goussard Y; Després P
Med Phys; 2015 Apr; 42(4):1505-17. PubMed ID: 25832041
[TBL] [Abstract][Full Text] [Related]
13. Tilted plane Feldkamp type reconstruction algorithm for spiral cone beam CT.
Yan M; Zhang C
Med Phys; 2005 Nov; 32(11):3455-67. PubMed ID: 16370432
[TBL] [Abstract][Full Text] [Related]
14. Evaluation and Clinical Application of a Commercially Available Iterative Reconstruction Algorithm for CBCT-Based IGRT.
Mao W; Liu C; Gardner SJ; Siddiqui F; Snyder KC; Kumarasiri A; Zhao B; Kim J; Wen NW; Movsas B; Chetty IJ
Technol Cancer Res Treat; 2019 Jan; 18():1533033818823054. PubMed ID: 30803367
[TBL] [Abstract][Full Text] [Related]
15. 3D alternating direction TV-based cone-beam CT reconstruction with efficient GPU implementation.
Cai A; Wang L; Zhang H; Yan B; Li L; Xi X; Guan M; Li J
Comput Math Methods Med; 2014; 2014():982695. PubMed ID: 25045400
[TBL] [Abstract][Full Text] [Related]
16. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.
Tang X; Hsieh J; Hagiwara A; Nilsen RA; Thibault JB; Drapkin E
Phys Med Biol; 2005 Aug; 50(16):3889-905. PubMed ID: 16077234
[TBL] [Abstract][Full Text] [Related]
17. An investigation of 4D cone-beam CT algorithms for slowly rotating scanners.
Bergner F; Berkus T; Oelhafen M; Kunz P; Pa T; Grimmer R; Ritschl L; Kachelriess M
Med Phys; 2010 Sep; 37(9):5044-53. PubMed ID: 20964224
[TBL] [Abstract][Full Text] [Related]
18. Parameter selection in limited data cone-beam CT reconstruction using edge-preserving total variation algorithms.
Lohvithee M; Biguri A; Soleimani M
Phys Med Biol; 2017 Nov; 62(24):9295-9321. PubMed ID: 29035874
[TBL] [Abstract][Full Text] [Related]
19. Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach.
Cho S; Lim S; Kim C; Wi S; Kwon T; Youn WS; Lee SH; Kang BS; Cho S
Phys Med; 2020 Feb; 70():1-9. PubMed ID: 31931280
[TBL] [Abstract][Full Text] [Related]
20. Efficient TpV minimization for circular, cone-beam computed tomography reconstruction via non-convex optimization.
Cai A; Wang L; Yan B; Li L; Zhang H; Hu G
Comput Med Imaging Graph; 2015 Oct; 45():1-10. PubMed ID: 26233922
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]