336 related articles for article (PubMed ID: 18703584)
1. Minimal invasive coronary sinus lead reposition technique for the treatment of phrenic nerve stimulation.
Szilágyi S; Merkely B; Zima E; Kutyifa V; Szucs G; Fülöp G; Molnár L; Szabolcs Z; Gellér L
Europace; 2008 Oct; 10(10):1157-60. PubMed ID: 18703584
[TBL] [Abstract][Full Text] [Related]
2. Influence of pacing configurations, body mass index, and position of coronary sinus lead on frequency of phrenic nerve stimulation and pacing thresholds under cardiac resynchronization therapy.
Seifert M; Schau T; Moeller V; Neuss M; Meyhoefer J; Butter C
Europace; 2010 Jul; 12(7):961-7. PubMed ID: 20444725
[TBL] [Abstract][Full Text] [Related]
3. Stabilization of the coronary sinus lead position with permanent stylet to prevent and treat dislocation.
Sharifkazemi MB; Aslani A
Europace; 2007 Oct; 9(10):875-7. PubMed ID: 17652150
[TBL] [Abstract][Full Text] [Related]
4. Long-term experience with coronary sinus side branch stenting to stabilize left ventricular electrode position.
Gellér L; Szilágyi S; Zima E; Molnár L; Széplaki G; Végh EM; Osztheimer I; Merkely B
Heart Rhythm; 2011 Jun; 8(6):845-50. PubMed ID: 21232629
[TBL] [Abstract][Full Text] [Related]
5. Long-term stability of endocardial left ventricular pacing leads placed via the coronary sinus.
Lin G; Anavekar NS; Webster TL; Rea RF; Hayes DL; Brady PA
Pacing Clin Electrophysiol; 2009 Sep; 32(9):1117-22. PubMed ID: 19719486
[TBL] [Abstract][Full Text] [Related]
6. Left ventricular pacing lead positioning in the target vein of the coronary sinus: description of a challenging case.
Frattini F; Rordorf R; Angoli L; Pentimalli F; Vicentini A; Petracci B; Magrini G; Landolina M
Pacing Clin Electrophysiol; 2008 Apr; 31(4):503-5. PubMed ID: 18373772
[TBL] [Abstract][Full Text] [Related]
7. Requirement for coronary sinus lead interventions and effectiveness of endovascular replacement during long-term follow-up after implantation of a resynchronization device.
Borleffs CJ; van Bommel RJ; Molhoek SG; de Leeuw JG; Schalij MJ; van Erven L
Europace; 2009 May; 11(5):607-11. PubMed ID: 19164363
[TBL] [Abstract][Full Text] [Related]
8. Usefulness of a pacing guidewire to facilitate left ventricular lead implantation in cardiac resynchronization therapy.
de Cock CC; Res JC; Hendriks ML; Allaart CP
Pacing Clin Electrophysiol; 2009 Apr; 32(4):446-9. PubMed ID: 19335852
[TBL] [Abstract][Full Text] [Related]
9. A novel approach for endocardial resynchronization therapy: initial experience with transapical implantation of the left ventricular lead.
Kassai I; Mihalcz A; Foldesi C; Kardos A; Szili-Torok T
Heart Surg Forum; 2009 Jun; 12(3):E137-40. PubMed ID: 19546062
[TBL] [Abstract][Full Text] [Related]
10. Reversing cardiac resynchronization therapy non-responder status in a patient with a surgically placed epicardial left ventricular lead by switching to an active fixation coronary sinus lead.
Nägele H; Behrens S; Azizi M
Europace; 2008 Oct; 10(10):1234-5. PubMed ID: 18593698
[TBL] [Abstract][Full Text] [Related]
11. Phrenic nerve stimulation with the quadripolar left ventricular lead not overcome by 'electronic repositioning'.
Kirubakaran S; Rinaldi CA
Europace; 2012 Apr; 14(4):608-9. PubMed ID: 22094452
[TBL] [Abstract][Full Text] [Related]
12. Minimal Invasive Left Ventricular Lead Repositioning is Safe and Effective in Distal Left Ventricular Lead Positions.
Osztheimer I; Szilágyi S; Pongor Z; Zima E; Molnár L; Tahin T; Merkely B; Gellér L
Pacing Clin Electrophysiol; 2017 May; 40(5):488-493. PubMed ID: 28240382
[TBL] [Abstract][Full Text] [Related]
13. Occurrence of phrenic nerve stimulation in cardiac resynchronization therapy patients: the role of left ventricular lead type and placement site.
Biffi M; Exner DV; Crossley GH; Ramza B; Coutu B; Tomassoni G; Kranig W; Li S; Kristiansen N; Voss F
Europace; 2013 Jan; 15(1):77-82. PubMed ID: 22848075
[TBL] [Abstract][Full Text] [Related]
14. Clinical and technical determinants of long-term performance of coronary sinus leads.
La Rocca V; Bertaglia E; Solimene F; Accogli M; Iuliano A; Marrazzo N; De Luca De Masi G; Scaccia A; Donnici G; Chiariello P; Turco P; De Simone A; Ciardiello C; Stabile G
J Cardiovasc Med (Hagerstown); 2010 Jan; 11(1):40-4. PubMed ID: 19770774
[TBL] [Abstract][Full Text] [Related]
15. Transseptal left ventricular endocardial pacing: preliminary experience from a femoral approach with subclavian pull-through.
van Gelder BM; Houthuizen P; Bracke FA
Europace; 2011 Oct; 13(10):1454-8. PubMed ID: 21561904
[TBL] [Abstract][Full Text] [Related]
16. [Reposition of the coronary sinus lead transvenously via femoral vein].
Kılıçaslan F; Uz O; Tokatlı A
Anadolu Kardiyol Derg; 2012 Feb; 12(1):82-3. PubMed ID: 22231945
[No Abstract] [Full Text] [Related]
17. Backup right ventricular pacing with a 0.035'' guidewire during implantation of left ventricular leads.
Burri H; Sunthorn H; Zimmermann M; Stettler C; Shah D
Pacing Clin Electrophysiol; 2009 Mar; 32 Suppl 1():S12-5. PubMed ID: 19250073
[TBL] [Abstract][Full Text] [Related]
18. Single-centre experience with coronary sinus lead stability and long-term pacing parameters.
Bulava A; Lukl J
Europace; 2007 Jul; 9(7):523-7. PubMed ID: 17507356
[TBL] [Abstract][Full Text] [Related]
19. Coronary sinus side branches for cardiac resynchronization therapy: prospective evaluation of availability, implant success, and procedural determinants.
Duray GZ; Hohnloser SH; Israel CW
J Cardiovasc Electrophysiol; 2008 May; 19(5):489-94. PubMed ID: 18298511
[TBL] [Abstract][Full Text] [Related]
20. Stimulation of the left ventricle through the coronary sinus with a newly developed 'over the wire' lead system--early experiences with lead handling and positioning.
Sack S; Heinzel F; Dagres N; Enger S; Auricchio A; Stellbrink C; Neuzner J; Potty P; Maarse A; Tockman B; Michel U; Erbel R
Europace; 2001 Oct; 3(4):317-23. PubMed ID: 11678391
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]